Cone Beam Computed Tomography, A Low-Dose Imaging Technique in the Postoperative Assessment of Cochlear Implantation

被引:78
|
作者
Ruivo, Joana [2 ]
Mermuys, Koen [1 ]
Bacher, Klaus [3 ]
Kuhweide, Rudolf [4 ]
Offeciers, Erwin [5 ]
Casselman, Jan W. [1 ]
机构
[1] AZ St Jan Hosp, Dept Radiol, B-8000 Brugge, Belgium
[2] Hosp Santa Maria, Serv Imagiol Neurol, Lisbon, Portugal
[3] Univ Ghent, Dept Med Phys & Radiat Protect, B-9000 Ghent, Belgium
[4] AZ St Jan Hosp, Dept Otorhinolaryngol, B-8000 Brugge, Belgium
[5] St Augustinus Hosp, Univ Dept Otolaryngol, Antwerp, Belgium
关键词
Inner ear; Cochlear implants; Cone beam computed tomography; Radiation dosage; Temporal bones; INSERTION DEPTH; MIDDLE-EAR; CT; ELECTRODE;
D O I
10.1097/MAO.0b013e31819679f9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Cone beam computed tomography (CBCT) has become an extremely useful technique for dentomaxillofacial imaging because it provides clear images of highly contrasted structures. Previous studies evaluating the applicability of this technique in otologic imaging were very encouraging but were only performed in vitro on temporal bone specimens. The intracochlear positioning of the individual electrodes after cochlear implantation by means of CBCT has not yet been shown in vivo. Objective: We describe a protocol for in vivo postoperative imaging of cochlear implants by CBCT. Moreover, the effective dose was measured and compared with the effective dose used on 4- and 16-slice multislice computed tomography (MSCT) by using a RANDO-phantom. Main Outcome Measure: Developing a protocol for in vivo postoperative imaging of cochlear implants by CBCT. Results: CBCT provides high-resolution and almost artifact-free multiplanar reconstruction images allowing assessment of the precise intracochlear position of the electrode and visualization of each of the individual contacts. The calculated effective dose of the used CBCT and MSCT acquisitions is 80 mu sv for the CBCT, 3,600 mu sv for the 16-slice computed tomography, and 4,800 mu sv for the 4-slice computed tomography. Conclusion: These preliminary results suggests that, for in vivo postoperative evaluation of cochlear implants, CBCT can provide at least the same information as conventional radiography, digital radiograph, and MSCT but in a more comfortable and a much more safer way.
引用
收藏
页码:299 / 303
页数:5
相关论文
共 50 条
  • [1] Imaging furcation defects with low-dose cone beam computed tomography
    Ruetters, Maurice
    Gehrig, Holger
    Kim, Ti-Sun
    Bartha, Valentin
    Bruckner, Thomas
    Schwindling, Franz Sebastian
    Felten, Anna
    Lux, Christopher
    Sen, Sinan
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [2] Imaging furcation defects with low-dose cone beam computed tomography
    Maurice Ruetters
    Holger Gehrig
    Ti-Sun Kim
    Valentin Bartha
    Thomas Bruckner
    Franz Sebastian Schwindling
    Anna Felten
    Christopher Lux
    Sinan Sen
    Scientific Reports, 12
  • [3] Cone beam computed tomography for dental and maxillofacial imaging: technique improvement and low-dose protocols
    Feragalli, Beatrice
    Rampado, Osvaldo
    Abate, Cecilia
    Macri, Monica
    Festa, Felice
    Stromei, Francesco
    Caputi, Sergio
    Guglielmi, Giuseppe
    RADIOLOGIA MEDICA, 2017, 122 (08): : 581 - 588
  • [4] Cone beam computed tomography for dental and maxillofacial imaging: technique improvement and low-dose protocols
    Beatrice Feragalli
    Osvaldo Rampado
    Cecilia Abate
    Monica Macrì
    Felice Festa
    Francesco Stromei
    Sergio Caputi
    Giuseppe Guglielmi
    La radiologia medica, 2017, 122 : 581 - 588
  • [5] Assessment of Cochlear Trauma During Cochlear Implantation Using Electrocochleography and Cone Beam Computed Tomography
    Dalbert, Adrian
    Huber, Alexander
    Veraguth, Dorothe
    Roosli, Christof
    Pfiffner, Flurin
    OTOLOGY & NEUROTOLOGY, 2016, 37 (05) : 446 - 453
  • [6] Image quality assessment of low-dose protocols in cone beam computed tomography of the anterior maxilla
    Ihlis, Randi Lynds
    Kadesjo, Nils
    Tsilingaridis, Georgios
    Benchimol, Daniel
    Shi, Xie Qi
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2022, 133 (04): : 483 - 491
  • [7] Advances in Imaging (Intraop Cone-Beam Computed Tomography, Synthetic Computed Tomography, Bone Scan, Low-Dose Protocols)
    Jankowski, Pawel P.
    Chan, Justin P.
    NEUROSURGERY CLINICS OF NORTH AMERICA, 2024, 35 (02) : 161 - 172
  • [8] Evaluation of a low-dose protocol for cone beam computed tomography of the temporomandibular joint
    Iskanderani, Durer
    Nilsson, Mats
    Alstergren, Per
    Shi, Xie-Qi
    Hellen-Halme, Kristina
    DENTOMAXILLOFACIAL RADIOLOGY, 2021, 50 (01)
  • [9] Evaluation of a low-dose protocol for cone beam computed tomography of the temporomandibular joint
    Iskanderani, Durer
    Nilsson, Mats
    Alstergren, Per
    Shi, Xie-Qi
    Hellen-Halme, Kristina
    DENTOMAXILLOFACIAL RADIOLOGY, 2020, 49 (06)
  • [10] Low-Dose Computed Tomography Colonography Technique
    Chang, Kevin J.
    Yee, Judy
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (05) : 709 - +