DMLC IMRT to moving tissues - Towards 4D therapy

被引:0
|
作者
Papiez, L.
McMahon, R.
Rangaraj, D.
机构
[1] Univ Texas, SW Med Ctr, Dallas, TX USA
[2] Purdue Univ, W Lafayette, IN 47907 USA
[3] Washington Univ, St Louis, MO USA
关键词
D O I
10.1118/1.2760819
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose. The goal of traditional approaches to IMRT delivery to moving tisues (gating, target outline tracking, IMRT tumor tracking) is to irradiate patient body so that effects of tisuue motion are eliminated and IMRT therapies in the presence of tissue motion are delivered so that the IMRT dose distributions for moving bodies are equivalent to the dose distribution delivered to the static body geometry. In contrast the proposed solution for IMRT delivery to moving tissues and organs aims at delivering treatments that are dosimetrically superior relative to any IMRT therapy possible for stationary body geometry. Methods. Treatment plans (3D) are derived for each phase of the (static) body geometry. This is done with existing planning software in comercial TPS and for body geometries defined by data scorred in 4D CT. Using the freedom of multiple solutions of DMLC IMRT delivery of given intensity map to moving target the exploitation of leaf trajectories and dose rate intensities are investigated (for each phase plan) to find the optimized treatment deliveries that are more advantageous than 3D IMRT plans derived for each phase of the static body geometry. The best deliverable plan among all derived for each of the motion phase is chosen as the one to be realized. The resulting intensity delivered by these strategies, and resulting dose distributions, are calculated and compared to best plans derived for each phase plans. Results. The example of treatment derived for particular phase of body motion geometry has been investigated. The DMLC IMRT delivery of given dose to target that simultaneously minimizes the dose delivered to organ at risk due to interaction between motion of leaves and motion of the target is calculated that shows the dosimetric advantage over 3D IMRT therapy. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
下载
收藏
页码:2438 / 2438
页数:1
相关论文
共 50 条
  • [41] Reconstruction of 4D deformed CT for moving anatomy
    Alen Docef
    Martin J. Murphy
    International Journal of Computer Assisted Radiology and Surgery, 2008, 3 : 591 - 598
  • [42] 4D radiotherapy planning strategies for moving targets
    Ma, Y.
    Lee, L.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S616 - S616
  • [43] Development operators on 4D moving object databases
    JUN Sung woo
    LEE Yang koo
    KIM Sang ho
    CHI Jeong hee
    RYU Keun ho
    重庆邮电大学学报(自然科学版), 2004, (05) : 108 - 112
  • [44] A robotic 4D phantom for the radiotherapy of moving objects
    Baier, K.
    Wilbert, J.
    Richter, A.
    Guckenberger, M.
    Flentje, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 : 15 - 15
  • [45] 4D functional imaging in the freely moving rat
    Holzer, Matthew
    Schmitz, Christoph
    Pei, Yaling
    Graber, Harry
    Abdul, Rehman-Ansari
    Barry, Jeremy
    Muller, Robert
    Barbour, Randall
    2006 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-15, 2006, : 2428 - 2431
  • [46] Calibration of a Novel 4D Diode Array for IMRT and VMAT QA
    Yan, G.
    Lu, B.
    Kozelka, J.
    Simon, W.
    Liu, C.
    Li, J.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [47] 4D IMRT Planning Using a Direct Aperture Morphing Method
    Gui, M.
    Feng, Y.
    Tang, G.
    Dhople, A.
    Yu, C.
    MEDICAL PHYSICS, 2009, 36 (06) : 2676 - +
  • [48] BEST IN PHYSICS (THERAPY)-4D IMRT Planning Using Highly-Parallelizable Particle Swarm Optimization
    Modiri, A.
    Gu, X.
    Sawant, A.
    MEDICAL PHYSICS, 2014, 41 (06) : 543 - 543
  • [49] 4D particle therapy PET simulation for moving targets irradiated with scanned ion beams
    Laube, K.
    Menkel, S.
    Bert, C.
    Enghardt, W.
    Helmbrecht, S.
    Saito, N.
    Fiedler, F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (03): : 513 - 533
  • [50] A Comparison of Geant4 and DPM for 4D Monte Carlo of Lung IMRT
    Hancox, C.
    Seco, J.
    Paganetti, H.
    MEDICAL PHYSICS, 2008, 35 (06)