Encapsulated Ge detectors: Development and first tests

被引:208
|
作者
Eberth, J
Thomas, HG
vonBrentano, P
Lieder, RM
Jager, HM
Kammerling, H
Berst, M
Gutknecht, D
Henck, R
机构
[1] UNIV COLOGNE, INST KERNPHYS, D-50937 COLOGNE, GERMANY
[2] FORSCHUNGSZENTRUM JULICH, FORSCHUNGSZENTRUM, INST KERNPHYS, D-52425 JULICH, GERMANY
[3] FORSCHUNGSZENTRUM JULICH GMBH, ZENT ABT TECHNOL, JULICH, GERMANY
[4] EURISYS MEASURES, STRASBOURG, FRANCE
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 1996年 / 369卷 / 01期
关键词
D O I
10.1016/0168-9002(95)00794-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper discusses the development and the realisation of an encapsulated Ge detector. The properties of a first prototype detector are: relative efficiency epsilon(rel) = 21.4%; energy resolution: Delta E(gamma(1.33 Mev)) = 2.10keV and Delta E(gamma(122 KeV)) = 1.10keV. The encapsulation technology offers advantages: several encapsulated Ge detectors can be mounted closely packed in a cryostat, all electronic parts of the first preamplifier stage are accessible and induced radiation damage of the Ge crystal can be annealed in a standard furnace.
引用
收藏
页码:135 / 140
页数:6
相关论文
共 50 条
  • [41] Review of Ge detectors for gamma spectroscopy
    Alexiev D.
    Reinhard M.I.
    Mo L.
    Rosenfeld A.R.
    Smith M.L.
    Australasian Physical and Engineering Sciences in Medicine, 2002, 25 (03): : 102 - 109
  • [42] Testing the Ge detectors for the MAJORANA DEMONSTRATOR
    Xu, W.
    Abgrall, N.
    Aguayo, E.
    Avignone, F. T., III
    Barabash, A. S.
    Bertrand, F. E.
    Boswell, M.
    Brudanin, V.
    Busch, M.
    Byram, D.
    Caldwell, A. S.
    Chan, Y-D.
    Christofferson, C. D.
    Combs, D. C.
    Cuesta, C.
    Detwiler, J. A.
    Doe, P. J.
    Efremenko, Yu.
    Egorov, V.
    Ejiri, H.
    Elliott, S. R.
    Fast, J. E.
    Finnerty, P.
    Fraenkle, F. M.
    Galindo-Uribarri, A.
    Giovanetti, G. K.
    Goett, J.
    Green, M. P.
    Gruszko, J.
    Guiseppe, V. E.
    Gusev, K.
    Hallin, A. L.
    Hazama, R.
    Hegai, A.
    Henning, R.
    Hoppe, E. W.
    Howard, S.
    Howe, M. A.
    Keeter, K. J.
    Kidd, M. F.
    Kochetov, O.
    Konovalov, S. I.
    Kouzes, R. T.
    LaFerriere, B. D.
    Leon, J.
    Leviner, L. E.
    Loach, J. C.
    MacMullin, J.
    MacMullin, S.
    Martin, R. D.
    13TH INTERNATIONAL CONFERENCE ON TOPICS IN ASTROPARTICLE AND UNDERGROUND PHYSICS, TAUP 2013, 2015, 61 : 807 - 815
  • [43] GE PHOTOCAPACITIVE MIS INFRARED DETECTORS
    BINARI, SC
    MILLER, WE
    SHER, A
    TSUO, YH
    JOURNAL OF APPLIED PHYSICS, 1979, 50 (12) : 7883 - 7886
  • [44] TIMING SYSTEM FOR GE(LI)-DETECTORS
    AKIMOV, YK
    ANDERT, K
    ORTLEPP, HG
    KALININ, AI
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1972, NS19 (03) : 404 - &
  • [45] Flexible Ge-on-polyimide detectors
    Ho, W. S.
    Dai, Y. -H.
    Deng, Y.
    Lin, C. -H.
    Chen, Y. -Y.
    Lee, C. -H.
    Liu, C. W.
    APPLIED PHYSICS LETTERS, 2009, 94 (26)
  • [46] TIME MEASUREMENTS WITH GE(LI) DETECTORS
    BRANDENB.JD
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1968, 13 (11): : 1404 - &
  • [47] A GATED INTEGRATOR FOR GE(LI) DETECTORS
    RASMUSSEN, VK
    NUCLEAR INSTRUMENTS & METHODS, 1970, 83 (01): : 39 - +
  • [48] Investigation of neutron interactions with Ge detectors
    Baginova, Miloslava
    Vojtyla, Pavol
    Povinec, Pavel P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 897 : 22 - 31
  • [49] TIMING CIRCUIT FOR GE(LI) DETECTORS
    KARLSSON, L
    NUCLEAR INSTRUMENTS & METHODS, 1973, 106 (01): : 161 - 169
  • [50] TIMING SYSTEM FOR GE(LI) DETECTORS
    GABRIEL, F
    SCHOPS, K
    KOEPERNIK, H
    NUCLEAR INSTRUMENTS & METHODS, 1972, 103 (03): : 501 - +