Encapsulated Ge detectors: Development and first tests

被引:208
|
作者
Eberth, J
Thomas, HG
vonBrentano, P
Lieder, RM
Jager, HM
Kammerling, H
Berst, M
Gutknecht, D
Henck, R
机构
[1] UNIV COLOGNE, INST KERNPHYS, D-50937 COLOGNE, GERMANY
[2] FORSCHUNGSZENTRUM JULICH, FORSCHUNGSZENTRUM, INST KERNPHYS, D-52425 JULICH, GERMANY
[3] FORSCHUNGSZENTRUM JULICH GMBH, ZENT ABT TECHNOL, JULICH, GERMANY
[4] EURISYS MEASURES, STRASBOURG, FRANCE
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 1996年 / 369卷 / 01期
关键词
D O I
10.1016/0168-9002(95)00794-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper discusses the development and the realisation of an encapsulated Ge detector. The properties of a first prototype detector are: relative efficiency epsilon(rel) = 21.4%; energy resolution: Delta E(gamma(1.33 Mev)) = 2.10keV and Delta E(gamma(122 KeV)) = 1.10keV. The encapsulation technology offers advantages: several encapsulated Ge detectors can be mounted closely packed in a cryostat, all electronic parts of the first preamplifier stage are accessible and induced radiation damage of the Ge crystal can be annealed in a standard furnace.
引用
收藏
页码:135 / 140
页数:6
相关论文
共 50 条
  • [31] First tests of large prototype DEPFET detectors for ATHENA's wide field imager
    Bonholzer, Michael
    Behrens, Annika
    Emberger, Valentin
    Herrmann, Sven
    Meidinger, Norbert
    Mueller-Seidlitz, Johannes
    Treberspurg, Wolfgang
    SPACE TELESCOPES AND INSTRUMENTATION 2018: ULTRAVIOLET TO GAMMA RAY, 2018, 10699
  • [32] ENCAPSULATED MODULES OF SILICON DETECTORS OF IONIZING RADIATION
    Vasilyev, G. P.
    Voloshin, V. K.
    Kiprich, S. K.
    Maslov, N. I.
    Naumov, S. V.
    Potin, S. M.
    Yalovenko, V. I.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2010, (03): : 200 - 204
  • [33] Development of 100 g Si and 250 g Ge detectors for a dark matter search
    Brink, PL
    Cabrera, B
    Chugg, B
    Clarke, RM
    Davies, A
    Nam, SW
    Young, BA
    CZECHOSLOVAK JOURNAL OF PHYSICS, 1996, 46 : 2887 - 2888
  • [34] TIMING SYSTEM FOR GE(LI) DETECTORS
    AKIMOV, YK
    ANDERT, K
    KALININ, AI
    ORTLEPP, HG
    NUCLEAR INSTRUMENTS & METHODS, 1972, 104 (03): : 581 - &
  • [35] CARRIER TRAPPING IN GE(LI) DETECTORS
    SHER, AH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1971, NS18 (01) : 175 - &
  • [36] TIMING CIRCUIT FOR GE(LI) DETECTORS
    GORNI, S
    HOCHNER, G
    NADAV, E
    ZMORA, H
    NUCLEAR INSTRUMENTS & METHODS, 1967, 53 (02): : 349 - &
  • [37] FURTHER EXPERIENCE WITH GE(GAMMA) DETECTORS
    LAWSON, EM
    NUCLEAR INSTRUMENTS & METHODS, 1971, 95 (02): : 361 - +
  • [38] TIME MEASUREMENTS WITH GE(LI) DETECTORS
    BRANDENBERGER, JD
    NUCLEAR INSTRUMENTS & METHODS, 1969, 69 (02): : 271 - +
  • [39] On the measurement of positron emitters with Ge detectors
    Peyres, Virginia
    Garcia-Torano, Eduardo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 637 (01): : 100 - 104
  • [40] CALCULATED EFFICIENCEIS OF GE(LI) DETECTORS
    HOTZ, HP
    MATHIESEN, JM
    HURLEY, JP
    NUCLEAR INSTRUMENTS & METHODS, 1965, 37 (01): : 93 - +