Comparative performance analysis for abdominal phantom ROI detectability according to CT reconstruction algorithm: ADMIRE

被引:2
|
作者
Shin, Jun-Bong [1 ,2 ]
Yoon, Do-Kun [1 ,2 ]
Pak, Seongyong [3 ]
Kwon, Yang-Ho [3 ]
Suh, Tae Suk [1 ,2 ]
机构
[1] Catholic Univ Korea, Dept Biomed Engn, Coll Med, Seoul, South Korea
[2] Catholic Univ Korea, Coll Med, Res Inst Biomed Engn, Seoul, South Korea
[3] Siemens Healthineers Ltd, Seoul, South Korea
来源
关键词
abdomen phantom; ADMIRE; FBP; MDCT; SAFIRE; MODELED ITERATIVE RECONSTRUCTION; LOW-CONTRAST DETECTABILITY; RADIATION-DOSE REDUCTION; COMPUTED-TOMOGRAPHY;
D O I
10.1002/acm2.12765
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose We compared and analyzed the detectability performance pertaining to an abdominal phantom including a region of interest (ROI) according to a computed tomography (CT) reconstruction algorithm. Methods Three types of reconstruction algorithms (FBP, SAFIRE, and ADMIRE) were used to evaluate the detectability performance using the abdominal phantom (phantom size: 25 x 18 x 28 cm(3)). The vendor default settings for routine multi-detector computed tomography abdominal scans were used. As the quantitative evaluation method, the contrast-to-noise ratio (CNR), difference in coefficient of variation (COV) with the normalization based on the FBP data, and the noise power spectrum (NPS) were measured. Results The characteristic of the ADMIRE-3 reconstructed image was higher than those of the FBP and SAFIRE-3 reconstructed images. The CNR values of the SAFIRE and ADMIRE images were much higher than the corresponding values of the FBP images. The difference in COV values for the ADMIRE images was similar to 1.2 times lower than the corresponding values of the SAFIRE images. Conclusion The comparative analysis of the abdominal phantom low-contrast resolution differences for each CT exposure parameters showed that ADMIRE demonstrated better results than SAFIRE and FBP in terms of contrast, CNR, COV difference, and 1D NPS. This indicates that ADMIRE can provide a clearer observation even with the same number of contrast objects as compared to SAFIRE and FBP owing to its better contrast resolution in the central part of the contrast hole at low kV.
引用
收藏
页码:136 / 143
页数:8
相关论文
共 50 条
  • [31] Effect of Low Tube Voltage on Image Quality, Radiation Dose, and Low-Contrast Detectability at Abdominal Multidetector CT: Phantom Study
    Tang, Kun
    Wang, Ling
    Li, Rui
    Lin, Jie
    Zheng, Xiangwu
    Cao, Guoquan
    JOURNAL OF BIOMEDICINE AND BIOTECHNOLOGY, 2012,
  • [32] Image quality assessment of an iterative reconstruction algorithm applied to abdominal CT imaging
    Funama, Yoshinori
    Taguchi, Katsuyuki
    Utsunomiya, Daisuke
    Oda, Seitaro
    Katahira, Kazuhiro
    Tokuyasu, Shinichi
    Yamashita, Yasuyuki
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (04): : 527 - 534
  • [33] Dose reduction and image quality in CT examinations using an iterative reconstruction algorithm: a phantom study
    Guariglia, S.
    Meliado, G.
    Zivelonghi, E.
    Pinali, L.
    Montemezzi, S.
    Cavedon, C.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2015, 1 (04):
  • [34] Renal cyst pseudoenhancement: Influence of multidetector CT reconstruction algorithm and scanner type in phantom model
    Birnbaum, Bernard A.
    Hindman, Nicole
    Lee, Julie
    Babb, James S.
    RADIOLOGY, 2007, 244 (03) : 767 - 775
  • [35] Impact of CT reconstruction algorithm on auto-segmentation performance
    Miller, Claudia
    Mittelstaedt, Daniel
    Black, Noel
    Klahr, Paul
    Nejad-Davarani, Siamak
    Schulz, Heinrich
    Goshen, Liran
    Han, Xiaoxia
    Ghanem, Ahmed, I
    Morris, Eric D.
    Glide-Hurst, Carri
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (09): : 95 - 103
  • [36] Quantitative analysis of xQuant reconstruction algorithm in SPECT/CT
    Chen, Ew-Jun
    Safwan Selvam, Haniff Shazwan
    Tan, Teik Hin
    Chew, Ming Tsuey
    Radiation Physics and Chemistry, 2021, 188
  • [37] Quantitative analysis of xQuant reconstruction algorithm in SPECT/CT
    Chen, Ew-Jun
    Selvam, Haniff Shazwan Safwan
    Tan, Teik Hin
    Chew, Ming Tsuey
    RADIATION PHYSICS AND CHEMISTRY, 2021, 188
  • [38] Usefulness of a Metal Artifact Reduction Algorithm for Orthopedic Implants in Abdominal CT: Phantom and Clinical Study Results
    Jeong, Seonji
    Kim, Se Hyung
    Hwang, Eui Jin
    Shin, Cheong-Il
    Han, Joon Koo
    Choi, Byung Ihn
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (02) : 307 - 317
  • [39] Analysis of performance evaluation of parallel Katsevich algorithm for 3-D CT image reconstruction
    Ni, Jun
    Deng, Junjun
    Yu, Hengyong
    He, Tao
    Wang, Ge
    FIRST INTERNATIONAL MULTI-SYMPOSIUMS ON COMPUTER AND COMPUTATIONAL SCIENCES (IMSCCS 2006), PROCEEDINGS, VOL 1, 2006, : 258 - +
  • [40] Speedup performance analysis of parallel Katsevich algorithm for 3D CT image reconstruction
    Ni, Jun
    Deng, Junjun
    He, Tao
    Yu, Hengyong
    Wang, Ge
    INTERNATIONAL JOURNAL OF COMPUTATIONAL SCIENCE AND ENGINEERING, 2011, 6 (03) : 151 - 159