Monitoring dynamic breast measurements obtained from 4D body scanning

被引:8
|
作者
Pei, Jie [1 ]
Griffin, Linsey [2 ]
Ashdown, Susan P. [1 ]
Fan, Jintu [3 ]
机构
[1] Cornell Univ, Fiber Sci & Apparel Design, Ithaca, NY 14850 USA
[2] Univ Minnesota Twin Cities, Dept Design Housing & Apparel, St Paul, MN USA
[3] Hong Kong Polytech Univ, Inst Text & Clothing, Kowloon, Hong Kong, Peoples R China
关键词
4D body scanning; Breast measurements; Dynamic breast shape; BRA FIT; VOLUME; WOMEN; SHAPE; SIZE; ACCURATE; DENSITY; SUPPORT; SYSTEM; NUDE;
D O I
10.1108/IJCST-10-2020-0157
中图分类号
TB3 [工程材料学]; TS1 [纺织工业、染整工业];
学科分类号
0805 ; 080502 ; 0821 ;
摘要
Purpose The purpose of this study is to investigate the shape change of breast during movement to inform product development of bras and other female wearable products. Design/methodology/approach Using the latest 4D body scanning technology, the authors monitored the change of seven non-circumferential breast measurements, including four linear measurements (widths, depth, etc.) and three angular measurements, across nine dynamic scans of a complete gait cycle during running. A series of statistical analysis were conducted to thoroughly investigate the measurement values in dynamic states compared with values extracted from static 3D scans. Findings Major findings are as follows: (1) For width-underbust, chest-depth, vertical-acromion and angle ABD, more than half of the dynamic frames presents a significant difference with the static frame. (2) Width-underbust and chest-depth measured in static can underestimate the actual values under motion. (3) vertical-acromion presents a W-shaped general trend for the nine dynamic frames with peaks observed at the keyframes (i.e. when a participant's right or left knee bends the most and rises to its highest level) and lows at the intermediate frames. (4) Angle ABD and angle BAD both present an M-shaped general trend, the exact opposite of a W-shaped trend. Originality/value While 3D body scanning and motion capture systems have both contributed significantly to the study of breast, 4D body scanning incorporates the advantages of both technologies and captures the 3D surface of the body during movement at each instant moment. This is one of the first studies that adopt the new technology for apparel applications.
引用
收藏
页码:724 / 743
页数:20
相关论文
共 50 条
  • [41] On the features of 4D gravity monitoring of the geological environment
    Dubovenko, Yu. I.
    Chernaya, O. A.
    GEOFIZICHESKIY ZHURNAL-GEOPHYSICAL JOURNAL, 2011, 33 (03): : 161 - 168
  • [42] 4D seismic monitoring grows as production tool
    He, W
    Anderson, RN
    Xu, LQ
    Boulanger, A
    Meadow, B
    Neal, R
    OIL & GAS JOURNAL, 1996, 94 (21) : 41 - &
  • [43] On the ambiguity of 4D gravity monitoring of geological media
    Dubovenko, Yu.
    Chorna, O.
    GEOFIZICHESKIY ZHURNAL-GEOPHYSICAL JOURNAL, 2010, 32 (04): : 41 - 46
  • [44] 4D seismic for oil-rim monitoring
    Staples, R
    Hague, P
    Weisenborn, T
    Ashton, P
    Michalek, B
    GEOPHYSICAL PROSPECTING, 2005, 53 (02) : 243 - 251
  • [45] Fully 4D reconstruction of dynamic SPECT images based on the estimation of spatiotemporal basis coefficients directly from projection measurements
    Abella, Monica
    Reutter, Bryan W.
    Jose Vaquero, Juan
    Desco, Manuel
    Gullberg, Grant T.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3877 - +
  • [46] Clinical use of a novel in vivo 4D monitoring system for simultaneous patient motion and dose measurements
    Cherpak, Amanda J.
    Cygler, Joanna E.
    Andrusyk, Steve
    Pantarotto, Jason
    MacRae, Robert
    Perry, Gad
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 (02) : 290 - 296
  • [47] Toward continuous 4D microgravity monitoring of volcanoes
    Williams-Jones, Glyn
    Rymer, Hazel
    Mauri, Guillaume
    Gottsmann, Joachim
    Poland, Michael
    Carbone, Daniele
    GEOPHYSICS, 2008, 73 (06) : WA19 - WA28
  • [48] Intelligent 4D CT Sequence Scanning (i4DCT)
    Werner, R.
    Sentker, T.
    Madesta, F.
    Gauer, T.
    Hofmann, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : S5 - S5
  • [49] MEASURE4DHAND: DYNAMIC HAND MEASUREMENT EXTRACTION FROM 4D SCANS
    Dai, Xinxin
    Zhao, Ran
    Hu, Pengpeng
    Palade, Vasile
    Munteanu, Adrian
    2023 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, ICIP, 2023, : 3543 - 3547
  • [50] Comparison of intelligent 4D CT sequence scanning and conventional spiral 4D CT: A first comprehensive phantom study
    Werner R.
    Szkitsak J.
    Sentker T.
    Madesta F.
    Schwarz A.
    Fernolendt S.
    Vornehm M.
    Gauer T.
    Bert C.
    Hofmann C.
    Physics in Medicine and Biology, 2021, 66 (01):