Analysis of the microvascular morphology and hemodynamics of breast cancer in mice using SPring-8 synchrotron radiation microangiography

被引:8
|
作者
Torii, Masae [1 ]
Fukui, Toshifumi [2 ]
Inoue, Masashi [2 ]
Kanao, Shotaro [3 ]
Umetani, Keiji [4 ]
Shirai, Mikiyasu [5 ]
Inagaki, Tadakatsu [5 ]
Tsuchimochi, Hirotsugu [5 ]
Pearson, James T. [5 ]
Toi, Masakazu [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Breast Surg, Kyoto, Japan
[2] Canon, Med Imaging Syst Dev Ctr, Tokyo, Japan
[3] Kyoto Univ, Dept Diagnost Imaging & Nucl Med, Grad Sch Med, Kyoto, Japan
[4] Japan Synchrotron Radiat Res Inst, Res & Utilizat Div, Sayo, Hyogo, Japan
[5] Natl Cerebral & Cardiovasc Ctr, Dept Cardiac Physiol, Res Inst, Osaka, Japan
来源
关键词
tumor microvessels; hemodynamics; quantitative analysis; SR microangiography; ANTI-ANGIOGENIC THERAPY; TUMOR MICROENVIRONMENT; MICROVESSEL DENSITY; PULMONARY-CIRCULATION; COMPUTED TOMOGRAPHY; MOUSE MODEL; GROWTH; DISEASES; VESSELS; NORMALIZATION;
D O I
10.1107/S1600577517008372
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Tumor vasculature is characterized by morphological and functional abnormalities. However, analysis of the dynamics in blood flow is still challenging because of limited spatial and temporal resolution. Synchrotron radiation (SR) microangiography above the K-edge of the iodine contrast agent can provide high-contrast imaging of microvessels in time orders of milliseconds. In this study, mice bearing the human breast cancer cell lines MDAMB231 and NOTCH4 overexpression in MDAMB231 (MDAMB231(NOTCH4+)) and normal mice were assessed using SR microangiography. NOTCH is transmembrane protein that has crucial roles for vasculogenesis, angiogenesis and tumorigenesis, and NOTCH4 is considered to be a cause of high-flow arteriovenous shunting. A subgroup of mice received intravenous eribulin treatment, which is known to improve intratumor core circulation (MDAMB231_eribulin). Microvessel branches from approximately 200 mu m to less than 20 mu m in diameter were observed within the same visual field. The mean transition time (MTT) was measured as a dynamic parameter and quantitative analysis was performed. MTT in MDAMB231 was longer than that in normal tissue, and MDAMB231(NOTCH4+) showed shorter MTT [ 5.0 +/- 1.4 s, 3.6 +/- 1.0 s and 3.6 +/- 1.1 s (mean +/- standard deviation), respectively]. After treatment, average MTT was correlated to tumor volume (r = 0.999) in MDAMB231_eribulin, while in contrast there was no correlation in MDAMB231 (r = -0.026). These changes in MTT profile are considered to be driven by the modulation of intratumoral circulation dynamics. These results demonstrate that a SR microangiography approach enables quantitative analysis of morphological and dynamic characteristics of tumor vasculature in vivo. Further studies will reveal new findings concerning vessel function in tumors.
引用
收藏
页码:1039 / 1047
页数:9
相关论文
共 50 条
  • [1] Experimental studies of the microangioarchitecture of tumors using synchrotron radiation at SPring-8
    Yamashita, T
    Imai, S
    Maehara, N
    Kajihara, Y
    Umetani, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 1346 - 1348
  • [2] Microangiography in Living Mice Using Synchrotron Radiation
    Yuan, Falei
    Wang, Yongting
    Guan, Yongjing
    Lu, Haiyan
    Xie, Bohua
    Tang, Yaohui
    Xie, Honglan
    Du, Guohao
    Xiao, Tiqiao
    Yang, Guo-Yuan
    6TH INTERNATIONAL CONFERENCE ON MEDICAL APPLICATIONS OF SYNCHROTRON RADIATION, 2010, 1266 : 68 - +
  • [3] Dosimetry for a microbeam array generated by synchrotron radiation at SPring-8
    Torikoshi, Masami
    Ohno, Yumiko
    Yagi, Naoto
    Umetani, Keiji
    Furusawa, Yoshiya
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) : S114 - S117
  • [4] Rapid Single Crystal Structure Analysis Using High-Flux Synchrotron Radiation of SPring-8
    Yasuda, Nobuhiro
    Kimura, Shigeru
    13TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2018), 2019, 2054
  • [5] Characteristics of shielding design calculation for the SPring-8 synchrotron radiation beamlines
    Asano, Y
    Sasamoto, N
    RADIATION PROTECTION DOSIMETRY, 1999, 82 (03) : 167 - 174
  • [6] X-ray refraction-contrast imaging using synchrotron radiation at SPring-8
    Umetani, K
    Yagi, N
    Suzuki, Y
    Kohmura, Y
    Yamasaki, K
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 560 - 571
  • [7] Prospects for X-ray crystal structure analysis of selenoproteins with SPring-8 synchrotron radiation
    Yamamoto, M
    Kumasaka, T
    Yamashita, E
    Moriyama, H
    Sato, M
    Ueki, T
    JOURNAL OF HEALTH SCIENCE, 2000, 46 (06) : 426 - 429
  • [8] CONSTRUCTION PLAN OF LARGE SYNCHROTRON RADIATION FACILITY (SPRING-8) AND ITS APPLICATION
    HARAMI, T
    YOKOMIZO, H
    OHNO, H
    HARA, M
    UEKI, T
    JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 1991, 33 (04): : 310 - 317
  • [9] Monitoring system for a synthesizer at SPring-8 synchrotron radiation facility and obtained results
    Kawashima, Y.
    Ego, H.
    Hara, M.
    Ohashi, Y.
    Ohshima, T.
    Takao, M.
    Takashima, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 701 : 243 - 248
  • [10] X-ray diffraction studies of expanded fluid mercury using synchrotron radiation at SPring-8
    Tamura, K
    Inui, M
    Nakaso, I
    Oh'ishi, Y
    Funakoshi, K
    Utsumi, W
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1999, 38 : 452 - 455