Analysis of the microvascular morphology and hemodynamics of breast cancer in mice using SPring-8 synchrotron radiation microangiography

被引:8
|
作者
Torii, Masae [1 ]
Fukui, Toshifumi [2 ]
Inoue, Masashi [2 ]
Kanao, Shotaro [3 ]
Umetani, Keiji [4 ]
Shirai, Mikiyasu [5 ]
Inagaki, Tadakatsu [5 ]
Tsuchimochi, Hirotsugu [5 ]
Pearson, James T. [5 ]
Toi, Masakazu [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Breast Surg, Kyoto, Japan
[2] Canon, Med Imaging Syst Dev Ctr, Tokyo, Japan
[3] Kyoto Univ, Dept Diagnost Imaging & Nucl Med, Grad Sch Med, Kyoto, Japan
[4] Japan Synchrotron Radiat Res Inst, Res & Utilizat Div, Sayo, Hyogo, Japan
[5] Natl Cerebral & Cardiovasc Ctr, Dept Cardiac Physiol, Res Inst, Osaka, Japan
来源
关键词
tumor microvessels; hemodynamics; quantitative analysis; SR microangiography; ANTI-ANGIOGENIC THERAPY; TUMOR MICROENVIRONMENT; MICROVESSEL DENSITY; PULMONARY-CIRCULATION; COMPUTED TOMOGRAPHY; MOUSE MODEL; GROWTH; DISEASES; VESSELS; NORMALIZATION;
D O I
10.1107/S1600577517008372
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Tumor vasculature is characterized by morphological and functional abnormalities. However, analysis of the dynamics in blood flow is still challenging because of limited spatial and temporal resolution. Synchrotron radiation (SR) microangiography above the K-edge of the iodine contrast agent can provide high-contrast imaging of microvessels in time orders of milliseconds. In this study, mice bearing the human breast cancer cell lines MDAMB231 and NOTCH4 overexpression in MDAMB231 (MDAMB231(NOTCH4+)) and normal mice were assessed using SR microangiography. NOTCH is transmembrane protein that has crucial roles for vasculogenesis, angiogenesis and tumorigenesis, and NOTCH4 is considered to be a cause of high-flow arteriovenous shunting. A subgroup of mice received intravenous eribulin treatment, which is known to improve intratumor core circulation (MDAMB231_eribulin). Microvessel branches from approximately 200 mu m to less than 20 mu m in diameter were observed within the same visual field. The mean transition time (MTT) was measured as a dynamic parameter and quantitative analysis was performed. MTT in MDAMB231 was longer than that in normal tissue, and MDAMB231(NOTCH4+) showed shorter MTT [ 5.0 +/- 1.4 s, 3.6 +/- 1.0 s and 3.6 +/- 1.1 s (mean +/- standard deviation), respectively]. After treatment, average MTT was correlated to tumor volume (r = 0.999) in MDAMB231_eribulin, while in contrast there was no correlation in MDAMB231 (r = -0.026). These changes in MTT profile are considered to be driven by the modulation of intratumoral circulation dynamics. These results demonstrate that a SR microangiography approach enables quantitative analysis of morphological and dynamic characteristics of tumor vasculature in vivo. Further studies will reveal new findings concerning vessel function in tumors.
引用
收藏
页码:1039 / 1047
页数:9
相关论文
共 50 条
  • [21] Refraction-contrast imaging using undulator radiation at SPring-8
    Suzuki, Y.
    Yagi, N.
    Umetani, K.
    Kohmura, Y.
    Yamasaki, K.
    Proceedings of SPIE - The International Society for Optical Engineering, 3770 : 13 - 22
  • [22] Test Study for Generation of Short Pulsed Synchrotron Radiation by Kicker Magnet in SPring-8 Storage Ring
    Mitsuda, C.
    Fukami, K.
    Kobayashi, K.
    Masaki, M.
    Mochihashi, A.
    Nakanishi, T.
    Oishi, M.
    Schimizu, J.
    Shimosaki, Y.
    Shoji, M.
    Soutome, K.
    Tamura, K.
    Yonehara, H.
    Ohshima, T.
    SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 197 - +
  • [23] Performance of YB66 double-crystal monochromator for dispersing synchrotron radiation at SPring-8
    Kitamura, M
    Yoshikawa, H
    Mochizuki, T
    Vlaicu, AM
    Nisawa, A
    Yagi, N
    Okui, M
    Kimura, M
    Tanaka, T
    Fukushima, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 497 (2-3): : 550 - 562
  • [24] Elastic Modulus of the Crystalline Regions of Poly (p-phenylene terephthalamide) Single Fiber Using SPring-8 Synchrotron Radiation
    Masaru Kotera
    Aya Nakai
    Masahiko Saito
    Takayuki Izu
    Takashi Nishino
    Polymer Journal, 2007, 39 : 1295 - 1299
  • [25] Elastic modulus of the crystalline regions of poly (p-phenylene terephthalamide) single fiber using SPring-8 synchrotron radiation
    Kotera, Masaru
    Nakai, Aya
    Saito, Masahiko
    Izu, Takayuki
    Nishino, Takashi
    POLYMER JOURNAL, 2007, 39 (12) : 1295 - 1299
  • [26] Modular design of multi-wire moderator for slow positron source on hard synchrotron radiation SPring-8
    Nikitin, VP
    Plokhoi, VV
    Doronina, PP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 470 (1-2): : 50 - 52
  • [27] Computation of scattered radiation yield from target-moderator system for slow positron source on SPring-8 hard synchrotron radiation
    Plokhoi, VV
    Kandiev, YZ
    Kashaeva, EA
    Malyshkin, GN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 448 (1-2): : 102 - 105
  • [28] Study on efficiency of multi-wire tungsten moderator for slow positron source on SPring-8 hard synchrotron radiation
    Plokhoi, V
    Kandiev, Y
    Samarin, S
    Malyshkin, G
    Baidin, G
    Litvinenko, I
    Nikitin, V
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1999, 38 : 604 - 607
  • [29] Impacts of Diabetes and an SGLT2 Inhibitor on the Glomerular Number and Volume in db/db Mice, as Estimated by Synchrotron Radiation Micro-CT at SPring-8
    Takiyama, Yumi
    Sera, Toshihiro
    Nakamura, Masanori
    Ishizeki, Kanaki
    Saijo, Yasuaki
    Yanagimachi, Tsuyoshi
    Maeda, Manami
    Bessho, Ryoichi
    Takiyama, Takao
    Kitsunai, Hiroya
    Sakagami, Hidemitsu
    Fujishiro, Daisuke
    Fujita, Yukihiro
    Makino, Yuichi
    Abiko, Atsuko
    Hoshino, Masato
    Uesugi, Kentaro
    Yagi, Naoto
    Ota, Tsuguhito
    Haneda, Masakazu
    EBIOMEDICINE, 2018, 36 : 329 - 346
  • [30] Generation of high-energy synchrotron radiation with a 10-T superconducting wiggler installed in the SPring-8 storage ring
    Soutome, K
    Daté, S
    Ego, H
    Fukui, T
    Hara, M
    Hosoda, N
    Kawashima, Y
    Kodera, M
    Kumagai, N
    Magome, T
    Masaki, M
    Masuda, T
    Matsui, S
    Nakamura, T
    Noda, T
    Ohashi, Y
    Ohshima, T
    Oishi, M
    Saeki, H
    Sasaki, S
    Shoji, M
    Takano, S
    Takao, M
    Takashima, T
    Takebe, H
    Tamura, K
    Tanaka, H
    Taniuchi, Y
    Tsumaki, K
    Yorita, T
    Zhang, C
    Yonehara, H
    Schimizu, J
    Batrakov, A
    Karpov, G
    Kulipanov, G
    Kuzin, M
    Shkaruba, V
    Skrinsky, A
    Mezentsev, N
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 250 - 252