Dosimetry for a microbeam array generated by synchrotron radiation at SPring-8

被引:11
|
作者
Torikoshi, Masami [1 ]
Ohno, Yumiko [1 ]
Yagi, Naoto [2 ]
Umetani, Keiji [2 ]
Furusawa, Yoshiya [1 ]
机构
[1] Natl Inst Radiol Sci, Inage Ku, Chiba 2638555, Japan
[2] Japan Synchrotron Radiat Res Inst, Sayo, Hyogo 6795198, Japan
关键词
Dosimetry; Microbeam; Kodak EDR2 film; Synchrotron radiation;
D O I
10.1016/j.ejrad.2008.04.052
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A microbeam array was formed with a multi-slit collimator (MSC) for research on radiation therapy (MRT). Kodak EDR2 film was used to measure the dose distribution of the microbeam, array. The calibration curve of optical density of the film with respect to a dose was established using a standard Farmer chamber and Co-60 gamma-ray source. The peak dose of 3.6 Gy/s at the maximum was derived from the film dosimetry using the calibration curve. The uncertainty was estimated to be 5% which was mainly attributed to the uncertainty of the calibration. It was found that the ionization chamber used for monitoring the dose during the MRT experiments gave lower dose by about 30% than the dose derived from the film dosimetry. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:S114 / S117
页数:4
相关论文
共 50 条
  • [1] Beam commissioning of the SPring-8 synchrotron
    Suzuki, H
    Aoki, T
    Tani, N
    Fukami, K
    Hosoda, N
    Kobayashi, T
    Hayashi, S
    Ohzuchi, S
    Tanimoto, M
    Okanishi, K
    Sasaki, T
    Yonehara, H
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 357 - 359
  • [2] STATUS OF THE BOOSTER SYNCHROTRON FOR SPRING-8
    SUZUKI, H
    YONEHARA, H
    AOKI, T
    TANI, N
    KANEDA, T
    UEYAMA, Y
    SASAKI, Y
    NAGAFUCHI, T
    HAYASHI, S
    YOKOMIZO, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 1964 - 1967
  • [3] Beam commissioning of the SPring-8 synchrotron
    Suzuki, H.
    Aoki, T.
    Tani, N.
    Fukami, K.
    Hosoda, N.
    Kobayashi, T.
    Hayashi, S.
    Ohzuchi, S.
    Tanimoto, M.
    Okanishi, K.
    Sasaki, T.
    Yonehara, H.
    Journal of Synchrotron Radiation, 1998, 5 (03): : 357 - 359
  • [4] Characteristics of shielding design calculation for the SPring-8 synchrotron radiation beamlines
    Asano, Y
    Sasamoto, N
    RADIATION PROTECTION DOSIMETRY, 1999, 82 (03) : 167 - 174
  • [5] Experimental studies of the microangioarchitecture of tumors using synchrotron radiation at SPring-8
    Yamashita, T
    Imai, S
    Maehara, N
    Kajihara, Y
    Umetani, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 1346 - 1348
  • [6] CONSTRUCTION PLAN OF LARGE SYNCHROTRON RADIATION FACILITY (SPRING-8) AND ITS APPLICATION
    HARAMI, T
    YOKOMIZO, H
    OHNO, H
    HARA, M
    UEKI, T
    JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 1991, 33 (04): : 310 - 317
  • [7] Monitoring system for a synthesizer at SPring-8 synchrotron radiation facility and obtained results
    Kawashima, Y.
    Ego, H.
    Hara, M.
    Ohashi, Y.
    Ohshima, T.
    Takao, M.
    Takashima, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 701 : 243 - 248
  • [8] MOSFET dosimetry for microbeam radiation therapy at the European Synchrotron Radiation Facility
    Bräuer-Krisch, E
    Bravin, A
    Lerch, M
    Rosenfeld, A
    Stepanek, J
    Di Michiel, M
    Laissue, JA
    MEDICAL PHYSICS, 2003, 30 (04) : 583 - 589
  • [9] High-dose dosimetry system at SPring-8
    Nariyama, Nobuteru
    Magome, Tamotsu
    Ohishi, Masaya
    Yonehara, Hiroto
    RADIATION MEASUREMENTS, 2006, 41 : S274 - S278
  • [10] TLD dosimetry for microbeam radiation therapy at the European Synchrotron Radiation Facility
    Ptaszkiewicz, M.
    Braurer-Kirsch, E.
    Klosowski, M.
    Czopyk, L.
    Olko, P.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 990 - 993