A low-cost, highly functional, emergency use ventilator for the COVID-19 crisis

被引:6
|
作者
Raymond, Samuel J. [1 ]
Baker, Sam [2 ]
Liu, Yuzhe [1 ]
Bustamante, Mauricio J. [3 ]
Ley, Brett [4 ]
Horzewski, Michael J. [5 ]
Camarillo, David B. [1 ,5 ,6 ,7 ]
Cornfield, David N. [8 ]
机构
[1] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Comparat Med, Stanford, CA 94305 USA
[3] Univ Calif Berkeley, Dept Elect Engn & Comp Sci, Berkeley, CA USA
[4] Kaiser Pulmonol & Crit Care, Fontana, CA USA
[5] O2U Inc, Stanford, CA USA
[6] Stanford Univ, Dept Mech Engn, Stanford, CA 94305 USA
[7] Stanford Univ, Dept Neurosurg, Stanford, CA 94305 USA
[8] Stanford Univ, Dept Pediat Pulm Med, Stanford, CA 94305 USA
来源
PLOS ONE | 2022年 / 17卷 / 03期
关键词
ACUTE RESPIRATORY-DISTRESS; MECHANICAL VENTILATION;
D O I
10.1371/journal.pone.0266173
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Respiratory failure complicates most critically ill patients with COVID-19 and is characterized by heterogeneous pulmonary parenchymal involvement, profound hypoxemia and pulmonary vascular injury. The high incidence of COVID-19 related respiratory failure has exposed critical shortages in the supply of mechanical ventilators, and providers with the necessary skills to treat. Traditional mass-produced ventilators rely on an internal compressor and mixer to moderate and control the gas mixture delivered to a patient. However, the current emergency has energized the pursuit of alternative designs, enabling greater flexibility in supply chain, manufacturing, storage, and maintenance considerations. To achieve this, we hypothesized that using the medical gasses and flow interruption strategy would allow for a high performance, low cost, functional ventilator. A low-cost ventilator designed and built-in accordance with the Emergency Use guidance from the US Food and Drug Administration (FDA) is presented wherein pressurized medical grade gases enter the ventilator and time limited flow interruption determines the ventilator rate and tidal volume. This simple strategy obviates the need for many components needed in traditional ventilators, thereby dramatically shortening the time from storage to clinical deployment, increasing reliability, while still providing life-saving ventilatory support. The overall design philosophy and its applicability in this new crisis is described, followed by both bench top and animal testing results used to confirm the precision, safety and reliability of this low cost and novel approach to mechanical ventilation. The ventilator meets and exceeds the critical requirements included in the FDA emergency use guidelines. The ventilator has received emergency use authorization from the FDA.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Rapidly scalable and low-cost public health surveillance reporting system for COVID-19
    Jayaraj, Vivek Jason
    Ng, Chiu-Wan
    Hoe, Victor Chee-Wai
    Chong, Diane Woei-Quan
    Rampal, Sanjay
    BMJ HEALTH & CARE INFORMATICS, 2024, 31 (01)
  • [42] Simulation of pediatric intubation using a low-cost videolaryngoscope in the setting of the COVID-19 pandemic
    Rufach, Daniel
    Santos, Silvia
    Terebiznik, Marcelo
    ARCHIVOS ARGENTINOS DE PEDIATRIA, 2021, 119 (04): : 270 - 273
  • [43] A New Low-Cost and Accurate Diagnostic mHealth System for Patients with COVID-19 Pneumonia
    El Salti, Tarek
    Sykes, Edward R.
    Nievas, Javier
    Tong, Chen
    2022 IEEE INTERNATIONAL CONFERENCE ON DIGITAL HEALTH (IEEE ICDH 2022), 2022, : 123 - 128
  • [44] A sensitive, simple, and low-cost method for COVID-19 wastewater surveillance at an institutional level
    Liu, Pengbo
    Ibaraki, Makoto
    VanTassell, Jamie
    Geith, Kelly
    Cavallo, Matthew
    Kann, Rebecca
    Guo, Lizheng
    Moe, Christine L.
    Science of the Total Environment, 2022, 807
  • [45] Design of a Low-Cost Miniature Robot to Assist the COVID-19 Nasopharyngeal Swab Sampling
    Wang, Shuangyi
    Wang, Kehao
    Tang, Ruijie
    Qiao, Jingzhe
    Liu, Hongbin
    Hou, Zeng-Guang
    IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2021, 3 (01): : 289 - 293
  • [46] Assessing COVID-19 Emergency Use Authorizations
    Parasidis, Efthimios
    Berman, Micah L.
    Zettler, Patricia J.
    FOOD AND DRUG LAW JOURNAL, 2021, 76 (03) : 441 - 501
  • [47] Recent advances in low-cost, portable automated resuscitator systems to fight COVID-19
    Vishal Kumar
    Ravinder Kumar
    Mohit Kumar
    Gurpreet Singh Wander
    Vivek Gupta
    Ashish Sahani
    Health and Technology, 2022, 12 : 181 - 191
  • [48] Sensitive, Rapid, Low-Cost, and Multiplexed COVID-19 Monitoring by the Wireless Telemedicine Platform
    Zhang, Zhongyang
    Tang, Zhongmin
    Farokhzad, Nika
    Chen, Tianfeng
    Tao, Wei
    MATTER, 2020, 3 (06) : 1818 - 1820
  • [49] COVID-19 vaccine emergency use approval
    不详
    BULLETIN OF THE WORLD HEALTH ORGANIZATION, 2021, 99 (03) : 173 - 173
  • [50] Professional practices at the heart of the crisis in emergency management: The example of the COVID-19 crisis
    Villemain, A.
    Suarez, W.
    PSYCHOLOGIE DU TRAVAIL ET DES ORGANISATIONS, 2023, 29 (01) : 43 - 56