A low-cost, highly functional, emergency use ventilator for the COVID-19 crisis

被引:6
|
作者
Raymond, Samuel J. [1 ]
Baker, Sam [2 ]
Liu, Yuzhe [1 ]
Bustamante, Mauricio J. [3 ]
Ley, Brett [4 ]
Horzewski, Michael J. [5 ]
Camarillo, David B. [1 ,5 ,6 ,7 ]
Cornfield, David N. [8 ]
机构
[1] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Comparat Med, Stanford, CA 94305 USA
[3] Univ Calif Berkeley, Dept Elect Engn & Comp Sci, Berkeley, CA USA
[4] Kaiser Pulmonol & Crit Care, Fontana, CA USA
[5] O2U Inc, Stanford, CA USA
[6] Stanford Univ, Dept Mech Engn, Stanford, CA 94305 USA
[7] Stanford Univ, Dept Neurosurg, Stanford, CA 94305 USA
[8] Stanford Univ, Dept Pediat Pulm Med, Stanford, CA 94305 USA
来源
PLOS ONE | 2022年 / 17卷 / 03期
关键词
ACUTE RESPIRATORY-DISTRESS; MECHANICAL VENTILATION;
D O I
10.1371/journal.pone.0266173
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Respiratory failure complicates most critically ill patients with COVID-19 and is characterized by heterogeneous pulmonary parenchymal involvement, profound hypoxemia and pulmonary vascular injury. The high incidence of COVID-19 related respiratory failure has exposed critical shortages in the supply of mechanical ventilators, and providers with the necessary skills to treat. Traditional mass-produced ventilators rely on an internal compressor and mixer to moderate and control the gas mixture delivered to a patient. However, the current emergency has energized the pursuit of alternative designs, enabling greater flexibility in supply chain, manufacturing, storage, and maintenance considerations. To achieve this, we hypothesized that using the medical gasses and flow interruption strategy would allow for a high performance, low cost, functional ventilator. A low-cost ventilator designed and built-in accordance with the Emergency Use guidance from the US Food and Drug Administration (FDA) is presented wherein pressurized medical grade gases enter the ventilator and time limited flow interruption determines the ventilator rate and tidal volume. This simple strategy obviates the need for many components needed in traditional ventilators, thereby dramatically shortening the time from storage to clinical deployment, increasing reliability, while still providing life-saving ventilatory support. The overall design philosophy and its applicability in this new crisis is described, followed by both bench top and animal testing results used to confirm the precision, safety and reliability of this low cost and novel approach to mechanical ventilation. The ventilator meets and exceeds the critical requirements included in the FDA emergency use guidelines. The ventilator has received emergency use authorization from the FDA.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Design and Analysis of a Low-Cost Electronically Controlled Mobile Ventilator, Incorporating Mechanized AMBU Bag, for Patients during COVID-19 Pandemic
    Kshetry, Rohan Lal
    Gupta, Arnab
    Chattopadhyaya, Somnath
    Srivastava, Madhulika
    Sharma, Shubham
    Singh, Jujhar
    Das Gupta, Anirban
    Rajkumar, S.
    JOURNAL OF HEALTHCARE ENGINEERING, 2022, 2022
  • [32] Low-Cost Contact Thermometry for Screening and Monitoring During the COVID-19 Pandemic
    Yamanoor, Narasimha Sai
    Yamanoor, Srihari
    2020 IEEE INTERNATIONAL IOT, ELECTRONICS AND MECHATRONICS CONFERENCE (IEMTRONICS 2020), 2020, : 721 - 726
  • [33] Recovery of Chinese low-cost carriers after the outbreak of COVID-19 pandemic
    Liao, Maozhu
    Wu, Chuntao
    Yan, Hongmeng
    JOURNAL OF AIR TRANSPORT MANAGEMENT, 2022, 105
  • [34] A VERSATILE, LOW-COST ANIMAL VENTILATOR
    BAND, DM
    SNEYD, JR
    JOURNAL OF PHYSIOLOGY-LONDON, 1988, 407 : P2 - P2
  • [35] COST ANALYSIS FOR USE OF PROCALCITONIN AND INFLAMMATORY MARKERS IN COVID-19 VENTILATOR-ASSOCIATED PNEUMONIA
    Kim, A.
    Van, A.
    Mehta, J.
    CHEST, 2022, 161 (06) : 118A - 118A
  • [36] Antibiotic use in the COVID-19 crisis in Spain
    Gonzalez-Zorn, Bruno
    CLINICAL MICROBIOLOGY AND INFECTION, 2021, 27 (04) : 646 - 647
  • [37] Assessing the Risk of Spreading COVID-19 in the Room Utilizing Low-Cost Monitoring System
    Bujnak, Marek
    Pirnik, Rastislav
    Kuchar, Pavol
    Rastocny, Karol
    APPLIED SYSTEM INNOVATION, 2023, 6 (02)
  • [38] Recent advances in low-cost, portable automated resuscitator systems to fight COVID-19
    Kumar, Vishal
    Kumar, Ravinder
    Kumar, Mohit
    Wander, Gurpreet Singh
    Gupta, Vivek
    Sahani, Ashish
    HEALTH AND TECHNOLOGY, 2022, 12 (01) : 181 - 191
  • [39] A sensitive, simple, and low-cost method for COVID-19 wastewater surveillance at an institutional level
    Liu, Pengbo
    Ibaraki, Makoto
    VanTassell, Jamie
    Geith, Kelly
    Cavallo, Matthew
    Kann, Rebecca
    Guo, Lizheng
    Moe, Christine L.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 807
  • [40] Performance evaluation of a low-cost real time COVID-19 health monitoring system
    Mayada Abdelgadir Ahmed
    Monzir Hashim Mohammed
    Ibrahim Hassan Ahmed
    Journal of Electrical Systems and Information Technology, 10 (1)