Chest Compression With Personal Protective Equipment During Cardiopulmonary Resuscitation A Randomized Crossover Simulation Study

被引:45
|
作者
Chen, Jie [1 ]
Lu, Kai-Zhi [1 ]
Yi, Bin [1 ]
Chen, Yan [1 ]
机构
[1] Third Mil Med Univ, Southwest Hosp, Dept Anaesthesiol, Gaotanyan 19 St, Chongqing 400038, Peoples R China
关键词
HOSPITAL CARDIAC-ARREST; EMERGENCY CARDIOVASCULAR CARE; HEART-ASSOCIATION GUIDELINES; RESCUER FATIGUE; TOKYO SUBWAY; PERFORMANCE; MANAGEMENT; QUALITY; ATTACK;
D O I
10.1097/MD.0000000000003262
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Following a chemical, biological, radiation, and nuclear incident, prompt cardiopulmonary resuscitation (CPR) procedure is essential for patients who suffer cardiac arrest. But CPR when wearing personal protection equipment (PPE) before decontamination becomes a challenge for healthcare workers (HCW). Although previous studies have assessed the impact of PPE on airway management, there is little research available regarding the quality of chest compression (CC) when wearing PPE. A present randomized cross-over simulation study was designed to evaluate the effect of PPE on CC performance using mannequins. The study was set in one university medical center in the China.Forty anesthesia residents participated in this randomized cross-over study. Each participant performed 2 min of CC on a manikin with and without PPE, respectively. Participants were randomized into 2 groups that either performed CC with PPE first, followed by a trial without PPE after a 180-min rest, or vice versa.CPR recording technology was used to objectively quantify the quality of CC. Additionally, participants' physiological parameters and subjective fatigue score values were recorded. With the use of PPE, a significant decrease of the percentage of effective compressions (41.317.1% with PPE vs 67.5 +/- 15.6% without PPE, P<0.001) and the percentage of adequate compressions (67.7 +/- 18.9% with PPE vs 80.7 +/- 15.5% without PPE, P<0.001) were observed. Furthermore, the increases in heart rate, mean arterial pressure, and subjective fatigue score values were more obvious with the use of PPE (all P<0.01). We found significant deterioration of CC performance in HCW with the use of a level-C PPE, which may be a disadvantage for enhancing survival of cardiac arrest.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Effects of kneeling posture on chest compression during cardiopulmonary resuscitation in males
    Ho, Michael S. H.
    Chow, Daniel H. K.
    JOURNAL OF CLINICAL NURSING, 2018, 27 (3-4) : 777 - 783
  • [42] Rescuers' characteristics associated with the correct chest compression during cardiopulmonary resuscitation
    Ballesteros-Pena, S.
    Vallejo-de La Hoz, G.
    Fernandez-Aedo, I
    Etayo-Sancho, A.
    Berasaluze-Sanz, L.
    Dominguez-Garcia, J.
    ENFERMERIA INTENSIVA, 2022, 33 (03): : 126 - 131
  • [43] Variability in chest compression rate calculations during pediatric cardiopulmonary resuscitation
    Landis, William P.
    Morgan, Ryan W.
    Reeder, Ron W.
    Graham, Kathryn
    Siems, Ashley
    Diddle, J. Wesley
    Pollack, Murray M.
    Maa, Tensing
    Fernandez, Richard P.
    Yates, Andrew R.
    Tilford, Bradley
    Ahmed, Tageldin
    Meert, Kathleen L.
    Schneiter, Carleen
    Bishop, Robert
    Mourani, Peter M.
    Naim, Maryam Y.
    Friess, Stuart
    Burns, Candice
    Manga, Arushi
    Franzon, Deborah
    Tabbutt, Sarah
    McQuillen, Patrick S.
    Horvat, Christopher M.
    Bochkoris, Matthew
    Carcillo, Joseph A.
    Huard, Leanna
    Federman, Myke
    Sapru, Anil
    Viteri, Shirley
    Hehir, David A.
    Notterman, Daniel A.
    Holubkov, Richard
    Dean, J. Michael
    Nadkarni, Vinay M.
    Berg, Robert A.
    Wolfe, Heather A.
    Sutton, Robert M.
    RESUSCITATION, 2020, 149 : 127 - 133
  • [44] Effect of a dynamic mattress on chest compression quality during cardiopulmonary resuscitation
    Torsy, Tim
    Deswarte, Wim
    Karlberg Traav, Malin
    Beeckman, Dimitri
    NURSING IN CRITICAL CARE, 2022, 27 (02) : 275 - 281
  • [45] Electrocardiogram waveforms for monitoring effectiveness of chest compression during cardiopulmonary resuscitation
    Li, Yongqin
    Ristagno, Giuseppe
    Bisera, Joe
    Tang, Wanchun
    Deng, Qinkai
    Weil, Max Harry
    CRITICAL CARE MEDICINE, 2008, 36 (01) : 211 - 215
  • [46] The prevalence of chest compression leaning during in-hospital cardiopulmonary resuscitation
    Fried, David A.
    Leary, Marion
    Smith, Douglas A.
    Sutton, Robert M.
    Niles, Dana
    Herzberg, Daniel L.
    Becker, Lance B.
    Abella, Benjamin S.
    RESUSCITATION, 2011, 82 (08) : 1019 - 1024
  • [47] A mannequin based comparative study of quality of chest compression with or without personal protective equipment (PPE)
    Yoe, Steven
    Firdaus, Riyadh
    Sugiarto, Adhrie
    ANAESTHESIA PAIN & INTENSIVE CARE, 2022, 26 (04) : 496 - 502
  • [48] Comparison of Ventilation Methods during Continuous Chest Compression Cardiopulmonary Resuscitation
    Chapman, Fred W.
    Melnick, Sharon B.
    Sullivan, Joseph L.
    Killingsworth, Cheryl
    Walcott, Gregory P.
    CIRCULATION, 2008, 118 (18) : S662 - S662
  • [49] Does level D personal protective equipment guard against hazardous biologic agents during cardiopulmonary resuscitation?
    Martin Rodriguez, Francisco
    Fernandez Perez, Cristina
    Castro Villamor, Miguel
    Martin Conty, Jose Luis
    Arnillas Gomez, Pedro
    Casado Vicente, Veronica
    EMERGENCIAS, 2018, 30 (02): : 119 - 122
  • [50] Chest Compression-Only Cardiopulmonary Resuscitation
    Ho, Anthony M. -H.
    Chung, David C.
    Mizubuti, Glenio B.
    Wan, Song
    ANESTHESIA AND ANALGESIA, 2016, 123 (05): : 1330 - 1330