Chest Compression With Personal Protective Equipment During Cardiopulmonary Resuscitation A Randomized Crossover Simulation Study

被引:45
|
作者
Chen, Jie [1 ]
Lu, Kai-Zhi [1 ]
Yi, Bin [1 ]
Chen, Yan [1 ]
机构
[1] Third Mil Med Univ, Southwest Hosp, Dept Anaesthesiol, Gaotanyan 19 St, Chongqing 400038, Peoples R China
关键词
HOSPITAL CARDIAC-ARREST; EMERGENCY CARDIOVASCULAR CARE; HEART-ASSOCIATION GUIDELINES; RESCUER FATIGUE; TOKYO SUBWAY; PERFORMANCE; MANAGEMENT; QUALITY; ATTACK;
D O I
10.1097/MD.0000000000003262
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Following a chemical, biological, radiation, and nuclear incident, prompt cardiopulmonary resuscitation (CPR) procedure is essential for patients who suffer cardiac arrest. But CPR when wearing personal protection equipment (PPE) before decontamination becomes a challenge for healthcare workers (HCW). Although previous studies have assessed the impact of PPE on airway management, there is little research available regarding the quality of chest compression (CC) when wearing PPE. A present randomized cross-over simulation study was designed to evaluate the effect of PPE on CC performance using mannequins. The study was set in one university medical center in the China.Forty anesthesia residents participated in this randomized cross-over study. Each participant performed 2 min of CC on a manikin with and without PPE, respectively. Participants were randomized into 2 groups that either performed CC with PPE first, followed by a trial without PPE after a 180-min rest, or vice versa.CPR recording technology was used to objectively quantify the quality of CC. Additionally, participants' physiological parameters and subjective fatigue score values were recorded. With the use of PPE, a significant decrease of the percentage of effective compressions (41.317.1% with PPE vs 67.5 +/- 15.6% without PPE, P<0.001) and the percentage of adequate compressions (67.7 +/- 18.9% with PPE vs 80.7 +/- 15.5% without PPE, P<0.001) were observed. Furthermore, the increases in heart rate, mean arterial pressure, and subjective fatigue score values were more obvious with the use of PPE (all P<0.01). We found significant deterioration of CC performance in HCW with the use of a level-C PPE, which may be a disadvantage for enhancing survival of cardiac arrest.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Realizing Optimal Chest Compression Fraction During Cardiopulmonary Resuscitation
    Talkington, Josh
    Dantu, Ram
    2016 IEEE FIRST INTERNATIONAL CONFERENCE ON CONNECTED HEALTH: APPLICATIONS, SYSTEMS AND ENGINEERING TECHNOLOGIES (CHASE), 2016, : 348 - 349
  • [22] Backboard use during cardiopulmonary resuscitation and chest compression quality
    Paganini, Matteo
    Mormando, Giulia
    Carfagna, Fabio
    Ingrassia, Pier Luigi
    EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2022, 29 (05) : 387 - 387
  • [23] Identifying the optimum chest compression point during cardiopulmonary resuscitation
    Olivari, Davide
    De Giorgio, Daria
    Fumagalli, Francesca
    Ristagno, Giuseppe
    HEART & LUNG, 2020, 49 (02): : 207 - 208
  • [24] The use of a backboard during cardiopulmonary resuscitation and chest compression quality
    Houthoofdt, Ruben
    Cuvelier, Zara
    Serraes, Brecht
    Haentjens, Carl
    Mpotos, Nicolas
    Blot, Stijn
    AUSTRALIAN CRITICAL CARE, 2023, 36 (02) : 172 - 173
  • [25] Comparison of Miller and Airtraq laryngoscopes for orotracheal intubation by physicians wearing CBRN protective equipment during infant resuscitation: a randomized crossover simulation study
    Pierre-Géraud Claret
    Renaud Asencio
    Damien Rogier
    Claire Roger
    Philippe Fournier
    Tu-Anh Tran
    Mustapha Sebbane
    Xavier Bobbia
    Jean Emmanuel de La Coussaye
    Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 24
  • [26] Comparison of Miller and Airtraq laryngoscopes for orotracheal intubation by physicians wearing CBRN protective equipment during infant resuscitation: a randomized crossover simulation study
    Claret, Pierre-Geraud
    Asencio, Renaud
    Rogier, Damien
    Roger, Claire
    Fournier, Philippe
    Tran, Tu-Anh
    Sebbane, Mustapha
    Bobbia, Xavier
    de la Coussaye, Jean Emmanuel
    SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2016, 24
  • [27] The effects of bed height and time on the quality of chest compressions delivered during cardiopulmonary resuscitation: a randomised crossover simulation study
    Lewinsohn, A.
    Sherren, P. B.
    Wijayatilake, D. S.
    EMERGENCY MEDICINE JOURNAL, 2012, 29 (08) : 660 - 663
  • [28] Impact of Personal Protective Equipment on Pediatric Cardiopulmonary Resuscitation Performance A Controlled Trial
    Donoghue, Aaron J.
    Kou, Maybelle
    Good, Grace L.
    Eiger, Carmel
    Nash, Mark
    Henretig, Fred M.
    Stacks, Helen
    Kochman, Adam
    Debski, Julie
    Chen, Jia-Yuh
    Sharma, Gaurav
    Hornik, Christoph P.
    Gosnell, Leigh
    Siegel, David
    Krug, Steven
    Adler, Mark D.
    PEDIATRIC EMERGENCY CARE, 2020, 36 (06) : 267 - 273
  • [29] Effects of personal protective equipment on cardiopulmonary resuscitation quality and outcomes: A systematic review
    Chung, Sung Phil
    Nehme, Ziad
    Johnson, Nicholas J.
    Lagina, Anthony
    Bray, Janet
    RESUSCITATION PLUS, 2023, 14
  • [30] Chest Compression Metrics During Adult In-Hospital Cardiopulmonary Resuscitation: A GWTG-Resuscitation Study
    O'Halloran, Amanda
    Morgan, Ryan
    Alvey, Jessica
    Reeder, Ron
    Patterson, Elizabeth
    Raymond, Tia
    Perman, Sarah
    Edelson, Dana
    Wolfe, Heather
    Nadkarni, Vinay
    Berg, Robert
    Abella, Benjamin
    Sutton, Robert
    CIRCULATION, 2024, 150