Evaluation of giant arachnoid granulations with high-resolution 3D-volumetric MR sequences at 3T

被引:9
|
作者
Ogul, Hayri [1 ]
Guven, Fadime [1 ]
Izgi, Emine [1 ]
Kantarci, Mecit [1 ]
机构
[1] Ataturk Univ, Med Fac, Dept Radiol, Erzurum, Turkey
关键词
Magnetic resonance imaging; Brain; Cerebrospinal fluid; DURAL SINUSES; SPACE; APPEARANCE; TRANSVERSE; HERNIATION; BRAIN; CT;
D O I
10.1016/j.ejrad.2019.108722
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the contribution to the diagnosis of the giant arachnoid granulations (AGs) of three-dimensional (3D) high-resolution magnetic resonance (MR) imaging sequences such as T2-weighted sampling perfection with application optimized contrasts using different flip-angle evolution (SPACE) and post-contrast T1-weighted magnetization prepared rapid gradient echo (MPRAGE). Materials and Methods: Patients with 45 giant AGs were included in this retrospective study. All the patients were performed 3D T2-weighted SPACE and contrast enhanced MR venography sequences, as well as conventional cerebral MR imaging sequences. Post-contrast T1 weighted MPRAGE sequence were performed on 38/45 patients. All cerebral MR examinations were reviewed by the 2 neuroradiologists. Each GA was evaluated carefully to assess location and mean diameter. Results: The most common location for giant AGs was at both transverse sinuses. Fluid signal feature within the giant AGs was not isointense to CSF on SE T1 and FLAIR MR imaging in 32 of 45 giant AGs. There were cerebral herniation into AG in 10 (22.2 %) of 45 giant AGs. 33 (73.3 %) of 45 giant AGs had central vein finding into AG in contrast enhanced MR venography. Signal void phenomenon into AG in 3D T2-weighted SPACE MR sequence was identified in 28 (62.2 %) of 45 giant AGs. Conclusions: Fluid within giant AGs had no completely CSF-like signal intensity on conventional and 3D high-resolution MR imaging sequences. Majority of CSF-incongruent fluid within giant AGs on conventional sequences is mostly due to intra-AG CSF flow.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] 3D High-Spatial-Resolution Cerebral MR Venography at 3T: A Contrast-Dose-Reduction Study
    Tomasian, A.
    Salamon, N.
    Krishnam, M. S.
    Finn, J. P.
    Villablanca, J. P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (02) : 349 - 355
  • [42] High-Resolution 3D MR Imaging of the Trochlear Nerve
    Choi, B. S.
    Kim, J. H.
    Jung, C.
    Hwang, J. -M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (06) : 1076 - 1079
  • [43] High-resolution imaging at 3T and 7T with multiring local volume coils
    Fakhereh Mirrashed
    Jonathan C. Sharp
    Iva Cheung
    Boguslaw Tomanek
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2004, 16 : 167 - 173
  • [44] High-resolution 3D MR spectroscopic imaging of the prostate at 3 T with the MLEV-PRESS sequence
    Chen, Albert P.
    Cunningham, Charles H.
    Kurhanewicz, John
    Xu, Duan
    Hurd, Ralph E.
    Pauly, John M.
    Carvajal, Lucas
    Karpodinis, Kostas
    Vigneron, Daniel B.
    MAGNETIC RESONANCE IMAGING, 2006, 24 (07) : 825 - 832
  • [45] High-resolution imaging at 3T and 7T with multiring local volume coils
    Mirrashed, F
    Sharp, JC
    Cheung, I
    Tomanek, B
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2004, 16 (04) : 167 - 173
  • [46] The voxelization and homogenization methods of high-resolution volumetric 3D display
    Tian, F. (ouman@shu.edu.cn), 1600, Institute of Computing Technology (25):
  • [47] High-resolution, quantitative 3D PET image reconstruction for the Siemens hybrid 3T MR/BrainPET scanner using the PET reconstruction software toolkit (PRESTO)
    Juergen Scheins
    Christoph Weirich
    Liliana Caldeira
    Philipp Lohmann
    Elena Rota Kops
    Lutz Tellmann
    Michaela Gaens
    Hans Herzog
    Uwe Pietrzyk
    N Jon Shah
    EJNMMI Physics, 1 (Suppl 1)
  • [48] Clinical High-Resolution 3D-MR Spectroscopic Imaging of the Human Brain at 7 T
    Hingerl, Lukas
    Strasser, Bernhard
    Moser, Philipp
    Hangel, Gilbert
    Motyka, Stanislav
    Heckova, Eva
    Gruber, Stephan
    Trattnig, Siegfried
    Bogner, Wolfgang
    INVESTIGATIVE RADIOLOGY, 2020, 55 (04) : 239 - 248
  • [49] Assessing early brain development in neonates by segmentation of high-resolution 3T MRI
    Gerig, G
    Prastawa, M
    Lin, WL
    Gilmore, J
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2003, PT 2, 2003, 2879 : 979 - 980
  • [50] Feasibility of 3D T1W sequences in contrast-material enhanced MR cisternography at 3T
    Algin, Oktay
    Koc, Ural
    Ayberk, Giyas
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2022, 52 (06) : 1943 - 1949