Evaluation of giant arachnoid granulations with high-resolution 3D-volumetric MR sequences at 3T

被引:9
|
作者
Ogul, Hayri [1 ]
Guven, Fadime [1 ]
Izgi, Emine [1 ]
Kantarci, Mecit [1 ]
机构
[1] Ataturk Univ, Med Fac, Dept Radiol, Erzurum, Turkey
关键词
Magnetic resonance imaging; Brain; Cerebrospinal fluid; DURAL SINUSES; SPACE; APPEARANCE; TRANSVERSE; HERNIATION; BRAIN; CT;
D O I
10.1016/j.ejrad.2019.108722
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the contribution to the diagnosis of the giant arachnoid granulations (AGs) of three-dimensional (3D) high-resolution magnetic resonance (MR) imaging sequences such as T2-weighted sampling perfection with application optimized contrasts using different flip-angle evolution (SPACE) and post-contrast T1-weighted magnetization prepared rapid gradient echo (MPRAGE). Materials and Methods: Patients with 45 giant AGs were included in this retrospective study. All the patients were performed 3D T2-weighted SPACE and contrast enhanced MR venography sequences, as well as conventional cerebral MR imaging sequences. Post-contrast T1 weighted MPRAGE sequence were performed on 38/45 patients. All cerebral MR examinations were reviewed by the 2 neuroradiologists. Each GA was evaluated carefully to assess location and mean diameter. Results: The most common location for giant AGs was at both transverse sinuses. Fluid signal feature within the giant AGs was not isointense to CSF on SE T1 and FLAIR MR imaging in 32 of 45 giant AGs. There were cerebral herniation into AG in 10 (22.2 %) of 45 giant AGs. 33 (73.3 %) of 45 giant AGs had central vein finding into AG in contrast enhanced MR venography. Signal void phenomenon into AG in 3D T2-weighted SPACE MR sequence was identified in 28 (62.2 %) of 45 giant AGs. Conclusions: Fluid within giant AGs had no completely CSF-like signal intensity on conventional and 3D high-resolution MR imaging sequences. Majority of CSF-incongruent fluid within giant AGs on conventional sequences is mostly due to intra-AG CSF flow.
引用
收藏
页数:7
相关论文
共 50 条
  • [11] Brain herniation into the transverse sinuses' arachnoid granulations in the pediatric population investigated with 3T MRI
    Sade, Recep
    Ogul, Hayri
    Polat, Gokhan
    Pirimoglu, Berhan
    Kantarci, Mecit
    ACTA NEUROLOGICA BELGICA, 2019, 119 (02) : 225 - 231
  • [12] High-resolution MR imaging of the knee at 3 T
    Niitsu, M
    Nakai, T
    Ikeda, K
    Tang, GY
    Yoshioka, H
    Itai, Y
    ACTA RADIOLOGICA, 2000, 41 (01) : 84 - 88
  • [13] Malformations of cortical development: High-resolution MR and diffusion tensor imaging of fiber tracts at 3T
    Lim, CCT
    Yin, H
    Loh, NK
    Chua, VGE
    Hui, F
    Barkovich, AJ
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (01) : 61 - 64
  • [14] High-Resolution Uniform MR Imaging of Finger Joints Using a Dedicated RF Coil at 3T
    Kwok, Wingchi E.
    You, Zhigang
    Monu, Johnny
    Seo, Gwysuk
    Ritchlin, Christopher
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (01) : 240 - 247
  • [15] Atherosclerosis of middle cerebral artery: Evaluation with high-resolution MR imaging at 3T (vol 204, pg 447, 2009)
    Li, Ming-li
    Xu, Wei-hai
    Song, Lan
    Feng, Feng
    You, Hui
    Ni, Jun
    Gao, Shan
    Cui, Li-ying
    Jin, Zheng-yu
    ATHEROSCLEROSIS, 2011, 217 (01) : 296 - 296
  • [16] High-Resolution 3T MR Angiography of the Carotid Arteries: Comparison of Manual and Semiautomated Quantification of Stenosis
    Habibi, R.
    Lell, M. M.
    Steiner, R.
    Ruehm, S. G.
    Sayre, J. W.
    Nael, K.
    Finn, J. P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (01) : 46 - 52
  • [17] CSpace® High-Resolution Volumetric 3D Display
    Refai, Hakki H.
    Melnik, George
    Willner, Mark
    THREE-DIMENSIONAL IMAGING, VISUALIZATION, AND DISPLAY 2013, 2013, 8738
  • [18] High-resolution 3D diffusion tensor MRI of anesthetized rhesus macaque brain at 3T
    Tounekti, Slimane
    Troalen, Thomas
    Bihan-Poudec, Yann
    Froesel, Mathilda
    Lamberton, Franck
    Ozenne, Valery
    Clery, Justine
    Richard, Nathalie
    Descoteaux, Maxime
    Ben Hamed, Suliann
    Hiba, Bassem
    NEUROIMAGE, 2018, 181 : 149 - 161
  • [19] Initial experience with 3D isotropic high-resolution 3 T MR arthrography of the wrist
    Sutherland, John K.
    Nozaki, Taiki
    Kaneko, Yasuhito
    Yu, Hon J.
    Rafijah, Gregory
    Hitt, David
    Yoshioka, Hiroshi
    BMC MUSCULOSKELETAL DISORDERS, 2016, 17
  • [20] Initial experience with 3D isotropic high-resolution 3 T MR arthrography of the wrist
    John K. Sutherland
    Taiki Nozaki
    Yasuhito Kaneko
    Hon J. Yu
    Gregory Rafijah
    David Hitt
    Hiroshi Yoshioka
    BMC Musculoskeletal Disorders, 17