New measuring device for estimating the pressure under compression garments

被引:12
|
作者
Maklewska, Elzbieta [1 ]
Nawrocki, Andrzej
Kowalski, Krzysztof
Andrzejewska, Ewa
Kuzanski, Wojciech
机构
[1] TRICOTEXTIL, Inst Knitting Tech & Technol, Clothing Res Dept, Lodz, Poland
[2] Tech Univ Lodz, Fac Text Engn & Marketing, PL-90924 Lodz, Poland
[3] Med Univ Lodz, Dept Paediat Surg & Oncol, Lodz, Poland
关键词
compressive strength; pressure; garment industry;
D O I
10.1108/09556220710741687
中图分类号
TB3 [工程材料学]; TS1 [纺织工业、染整工业];
学科分类号
0805 ; 080502 ; 0821 ;
摘要
Purpose - This paper aims to describe new measuring device designed for measuring the pressure exerted by textile products used in healing therapy of hypertrophic scars. The testing device called "Textilpress" has been used for verification of the usually used method of designing and manufacturing ready-made compression garment products. Design/methodology/approach - The pressure measurement, realized by use of the "Textilpress" device, is an indirect measuring method, which is based on the Laplace Law. The investigations described in this paper concern the pressure measuring under textile bands placed on the models representing selected parts of the human body with pre-set circumferences. For this purpose, rigid cylinders were prepared, covered by a layer of neoprene which simulated the susceptibility of human skin. Findings - The investigations described in this paper indicate that the "Textilpress" test-device may be used for pressure measuring exerted by compression bands on the cylinder surface. In order to estimate the pressure exerted on a particular body part with the shape close to a cylinder, a measurement should be carried out on a cylinder with a circumference similar to that of the selected part of the human body. Research limitations/implications - The "Textilpress" test-device may be used by the manufacturers for measuring pressures exerted by compression bands (manufactured from knitted fabrics) on the cylinder surface of a pre-set diameter. In order to estimate the pressure exerted on a particular body part with the shape close to a cylinder, a measurement should be carried out on a cylinder with a circumference similar to that of the selected part of the human body. Originality/value - As hospitals do not possess appropriate measuring devices, which would enable one to measure the pressure on the scar exerted by the textile garment, the pressure efficiency and the appropriate fittings are estimated subjectively for the particular case. The "Textilpress" device enables monitoring such pressure.
引用
收藏
页码:215 / 221
页数:7
相关论文
共 50 条
  • [41] A new device to noninvasively estimate the intraocular pressure produced during ocular compression
    Korenfeld, Michael S.
    Dueker, David K.
    CLINICAL OPHTHALMOLOGY, 2016, 10 : 71 - 77
  • [42] Reliability and clinical utility of the Pliance X for measuring pressure at the interface of pressure garments and burn scars in children
    Wiseman, Jodie
    Simons, Megan
    Kimble, Roy
    Tyack, Zephanie
    BURNS, 2018, 44 (07) : 1820 - 1828
  • [43] NEW DEVICE FOR ASHING OF BIOLOGICAL-MATERIAL UNDER PRESSURE
    SCHRAMEL, P
    WOLF, A
    SEIF, R
    KLOSE, BJ
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1980, 302 (01): : 62 - 64
  • [44] Measuring and estimating exchange market pressure in the EU
    Pentecost, EJ
    Van Hooydonk, C
    Van Poeck, A
    JOURNAL OF INTERNATIONAL MONEY AND FINANCE, 2001, 20 (03) : 401 - 418
  • [45] AN AUTOMATIC DEVICE FOR MEASURING STRESS RELAXATION IN COMPRESSION SPRINGS
    TRUS, AM
    INDUSTRIAL LABORATORY, 1963, 29 (11): : 1527 - 1528
  • [46] A Novel Capacitance-Based In-Situ Pressure Sensor for Wearable Compression Garments
    Lao, Steven
    Edher, Hamza
    Saini, Utkarsh
    Sixt, Jeffrey
    Salehian, Armaghan
    MICROMACHINES, 2019, 10 (11)
  • [47] RELIABILITY OF A NEW PORTABLE AUTOMATIC BLOOD-PRESSURE MEASURING DEVICE (PHYSIOPORT)
    LANGEWITZ, W
    DAHNERT, A
    RUDDEL, H
    MEDIZINISCHE WELT, 1987, 38 (23): : 816 - 821
  • [48] Comparing a new simple plantar pressure measuring device with pedobarographically measured pressures
    vanSchie, CHM
    Vileikyte, L
    Abbott, CA
    Shaw, JE
    Hollis, S
    Boulton, AJM
    DIABETOLOGIA, 1996, 39 : 1005 - 1005
  • [49] VOLUME-COMPRESSIVE OSCILLOMETRY AS NEW BLOOD PRESSURE-MEASURING DEVICE
    Shavarova, Elena
    Padaryan, Sergey
    Kobalava, Zhanna
    JOURNAL OF HYPERTENSION, 2018, 36 : E201 - E201
  • [50] A new ultrasound-guided esophageal variceal pressure-measuring device
    Miller, LS
    Dai, Q
    Thomas, A
    Chung, CY
    Park, J
    Irizarry, S
    Nguyen, T
    Thangada, V
    Miller, ES
    Kim, JK
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2004, 99 (07): : 1267 - 1273