A new device to noninvasively estimate the intraocular pressure produced during ocular compression

被引:4
|
作者
Korenfeld, Michael S. [1 ,2 ]
Dueker, David K. [3 ]
机构
[1] Comprehens Eye Care Ltd, 901 East 3rd St, Washington, MO 63090 USA
[2] Washington Univ, Dept Ophthalmol & Visual Sci, Washington, MO USA
[3] Hamad Med Corp, Doha, Qatar
来源
CLINICAL OPHTHALMOLOGY | 2016年 / 10卷
关键词
glaucoma; intraocular pressure; tonometer; ocular compression;
D O I
10.2147/OPTH.S92954
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To describe a noninvasive instrument that estimates intraocular pressure during episodes of external globe compression and to demonstrate the accuracy and reliability of this device by comparing it to the intraocular pressures simultaneously and manometrically measured in cannulated eyes. Methods: A thin fluid-filled bladder was constructed from flexible and inelastic plastic sheeting and was connected to a pressure transducer with high pressure tubing. The output of the pressure transducer was sent to an amplifier and recorded. This device was validated by measuring induced pressure in the fluid-filled bladder while digital pressure was applied to one surface, and the other surface was placed directly against a human cadaver eye or in vivo pig eye. The human cadaver and in vivo pig eyes were each cannulated to provide a manometric intraocular pressure control. Results: The measurements obtained with the newly described device were within similar to 5% of simultaneously measured manometric intraocular pressures in both a human cadaver and in vivo pig eye model for a pressure range of similar to 15-100 mmHg. Conclusion: This novel noninvasive device is useful for estimating the intraocular pressure transients induced during any form of external globe compression; this is a clinical setting where no other devices can be used to estimate intraocular pressure.
引用
收藏
页码:71 / 77
页数:7
相关论文
共 50 条
  • [1] An Ocular Compression Device for Reduction of Elevated Post Anesthetic Intraocular Pressure
    Preejith, S. P.
    Sivaprakasam, Mohanasankar
    Venkatakrishnan, Jaichandran
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 4819 - 4822
  • [2] EFFECT OF OCULAR COMPRESSION ON INTRAOCULAR-PRESSURE
    BOLLING, JP
    KURRLE, RW
    ODAY, DM
    OPHTHALMIC SURGERY AND LASERS, 1985, 16 (09): : 563 - 565
  • [3] RECOVERY OF INTRAOCULAR PRESSURE AND VITREOUS WEIGHT AFTER OCULAR COMPRESSION
    OBSTBAUM, SA
    ROBBINS, R
    BEST, M
    GALIN, MA
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1971, 71 (05) : 1059 - &
  • [4] Intraocular pressure and ocular perfusion during hemodialysis
    Barbosa, Carolina Pelegrini
    Stefanini, Francisco Rosa
    Penha, Fernando
    Goes, Miguel Angelo
    Draibe, Sergio Antonio
    Canziani, Maria Eugenia
    Paranhos Junior, Augusto
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2011, 74 (02) : 106 - 109
  • [5] Intraocular pressure variation from ocular compression in low and high myopia
    Xu, Fang-Yu
    Lam, Andrew K. C.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2024, 107 (02) : 213 - 218
  • [6] Intraocular pressure changes after peribulbar injections with and without ocular compression
    Bowman, R
    Liu, C
    Sarkies, N
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1996, 80 (05) : 394 - 397
  • [7] EFFECT OF OCULAR COMPRESSION (AUTOPRESSOR) ON INTRAOCULAR-PRESSURE IN PERIOCULAR ANESTHESIA
    ROPO, A
    RUUSUVAARA, P
    PALOHEIMO, M
    MAUNUKSELA, EL
    NIKKI, P
    ACTA OPHTHALMOLOGICA, 1990, 68 (02): : 227 - 229
  • [8] New device for artificial increasing intraocular pressure
    Preussner, PR
    Duran, A
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1996, 234 (11) : 683 - 687
  • [10] THE EFFECT OF EXTERNAL OCULAR COMPRESSION ON INTRAOCULAR-PRESSURE FOLLOWING RETROBULBAR ANESTHESIA
    PALAY, DA
    STULTING, RD
    OPHTHALMIC SURGERY AND LASERS, 1990, 21 (07): : 503 - 507