Point-of-Use Measurement of Salivary Cortisol levels

被引:0
|
作者
Yamaguchi, Masaki [1 ]
Yoshikawa, Suguru [1 ]
Tahara, Yusuke [1 ]
Niwa, Daisuke [2 ]
Imai, Yoshikatsu [2 ]
Shetty, Vivek [3 ]
机构
[1] Iwate Univ, Grad Sch Engn, 4-3-5 Ueda, Morioka, Iwate 0208551, Japan
[2] Nano Bion R&D Ctr Rohm Co Ltd, Kyoto, Japan
[3] Univ Calif Los Angeles, Sch Dent, Los Angeles, CA 90024 USA
基金
日本科学技术振兴机构;
关键词
DIAGNOSTICS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The objective is to develop a novel methodology to analyze cortisol levels in saliva as an index of neuroendocrine response. In order to realize a portable, rapid and hand held biosensor of cortisol, we proposed an immuno-chromatographic test-strip based biosensor consisting of a disposable test-strip and a monitor. A fabricated disposable type test-strip has a size of 5 x 1.5 x 50 mm(3). In order to realize an immuno-chromatographic test-strip, a glucose oxidase (GOD) -cortisol conjugate was newly synthesized, because the speed and selectivity of immunological reactions is particularly attractive as a strategy for molecular recognition of cortisol. The synthesized molecule was identified as the GOD-cortisol conjugate by both its molecular weight and specific detection of cortisol. Three min after addition of GOD enzyme assay solution, a color change reaction at a test line was observed. The R-2 value for the calibration curve of the cortisol test strip was 0.95, and the relationship between its reflectance, r, and the cortisol level was r = 0.629 (1-0.232e ((-1.78 x cortisol))). The fabricated cortisol biosensor enabled us to analyze cortisol concentrations between 1 - 10 ng/ml within 25 min of dropping a cortisol solution on the test strip. Thus, it is suggested that the cortisol biosensor may possibly be used for point-of-use measurements in hospitals.
引用
收藏
页码:346 / 346
页数:1
相关论文
共 50 条
  • [31] Salivary cortisol levels as a predictor of preeclampsia in adolescents
    Salvador-Moysen, Jaime
    Ramirez-Aranda, Jose M.
    Martinez-Lopez, Yolanda
    Aguilar-Duran, Marisela
    COLOMBIA MEDICA, 2012, 43 (01): : 46 - 53
  • [32] Low salivary cortisol levels and aggressive behavior
    Herzog, AG
    Edelheit, PB
    Jacobs, AR
    ARCHIVES OF GENERAL PSYCHIATRY, 2001, 58 (05) : 513 - 514
  • [33] Posttraumatic stress symptoms and salivary cortisol levels
    Anisman, H
    Griffiths, J
    Matheson, K
    Ravindran, AV
    Merali, Z
    AMERICAN JOURNAL OF PSYCHIATRY, 2001, 158 (09): : 1509 - 1511
  • [34] Salivary and serum cortisol levels in newborn infants
    Forclaz, Maria V.
    Moratto, Eduardo
    Pennisi, Alicia
    Falco, Silvina
    Olsen, Graciela
    Rodriguez, Patricia
    Papazian, Regina
    Bergada, Ignacio
    ARCHIVOS ARGENTINOS DE PEDIATRIA, 2017, 115 (03): : 262 - 266
  • [35] The effect of chiropractic manipulation on salivary cortisol levels
    Whelan, TL
    Dishman, JD
    Burke, J
    Levine, S
    Sciotti, V
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2002, 25 (03) : 149 - 153
  • [36] ASSOCIATION OF PHYSICAL ACTIVITY ON SALIVARY CORTISOL LEVELS
    Rayo, Jessica
    Sanchez, Hugo
    Urizar, Guido
    PSYCHOSOMATIC MEDICINE, 2016, 78 (03): : A81 - A81
  • [37] Baseline salivary cortisol levels and occupational fatigue
    Raymann, R
    Hanson, E
    Godaert, G
    van Doornen, L
    PSYCHOPHYSIOLOGY, 1999, 36 : S93 - S93
  • [38] Point-of-Use Hybrid Inventory Policy for Hospitals
    Rosales, Claudia R.
    Magazine, Michael
    Rao, Uday
    DECISION SCIENCES, 2014, 45 (05) : 913 - 937
  • [39] Analyzing available alternatives for point-of-use abatement
    Goolsby, B
    Vartanian, V
    Mendicino, L
    SOLID STATE TECHNOLOGY, 2003, 46 (07) : 132 - +
  • [40] POINT-OF-USE AIR DRYER IS ALL MECHANICAL
    不详
    HYDRAULICS & PNEUMATICS, 1994, 47 (12) : 10 - 10