Accuracy of Injection Into the First Dorsal Compartment: A Cadaveric Ultrasound Study

被引:9
|
作者
Kutsikovich, Jeffrey [1 ]
Merrell, Gregory [1 ]
机构
[1] Indiana Hand Shoulder Ctr, 8501 Harcourt Rd, Indianapolis, IN 46260 USA
来源
关键词
de Quervain; injection; ultrasound; QUERVAINS; TENOSYNOVITIS; SEPTUM;
D O I
10.1016/j.jhsa.2018.01.020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To determine the accuracy of ultrasound-guided (UG) injections compared with anatomic landmark-guided (AL) injections in the first dorsal compartment (FDC) with the hypothesis that ultrasound guidance would increase the accuracy of injection. Methods We randomized 43 above-elbow cadaveric specimens to receive latex dye injections into the FDC via a UG or AL technique. If ultrasound imaging identified a septated FDC, the needle was redirected and a portion of the dye was injected around the extensor pollicis brevis (EPB) tendon. Specimens were dissected and data collected regarding the location of the dye and presence of a septated FDC. Fisher exact test was used to calculate the difference in accuracy rates of injections. Results All 21 specimens injected via UG and all 22 specimens injected via the AL technique demonstrated dye within the FDC. Eight of 21 specimens in the UG group and 6 of 22 specimens in the AL group demonstrated a septated FDC upon dissection. Ultrasound was able to identify 6 of 8 specimens accurately with a septated FDC, representing a sensitivity of 75% and specificity of 92%. Six of 8 specimens with a septated FDC in the UG group versus 2 of 6 specimens with a septated FDC in the AL group demonstrated dye infiltration around the EPB. Dye was noted in the subcutaneous tissues in 2 of 21 specimens in the UG group versus 2 of 22 specimens in the AL group. Conclusions The UG-and AL-based injections both had excellent dye infiltration into a portion of the FDC. Ultrasound-guided injections had a higher observed infiltration rate in EPB sub-compartments than the AL technique, but could not be statistically confirmed to be different. Copyright (C) 2018 by the American Society for Surgery of the Hand. All rights reserved.
引用
收藏
页码:777.e1 / 777.e5
页数:5
相关论文
共 50 条
  • [1] Anatomical Basis for Injection around First Dorsal Compartment of the Wrist: A Fresh Cadaveric Study
    Cheong, In Yae
    Rhyu, Im Joo
    Kim, Ki Hoon
    Chung, Phil Woo
    Kim, Dasom
    Park, Byung Kyu
    Kim, Dong Hwee
    PAIN PHYSICIAN, 2016, 19 (06) : E893 - E900
  • [2] Indirect Ultrasound Guidance Increased Accuracy of the Glenohumeral Injection Using the Superior Approach: A Cadaveric Study of Injection Accuracy
    Kim, Joon Sung
    Kim, Min-Wook
    Park, Dong Yoon
    ANNALS OF REHABILITATION MEDICINE-ARM, 2013, 37 (02): : 202 - 207
  • [3] Accuracy of Measurement of Hand Compartment Pressures: A Cadaveric Study
    Wong, Justin C.
    Vosbikian, Michael M.
    Dwyer, Joseph M.
    Ilyas, Asif M.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (04): : 701 - 706
  • [4] A Cadaveric Study of the First Dorsal Compartment of the Wrist and Its Content Tendons: Anatomical Variations in the Indian Population
    Roy, Amlan Jyoti
    Roy, Amarendra Nath
    De, Chinmay
    Banerji, Debabrata
    Das, Suvam
    Chatterjee, Biplab
    Halder, Tarak Chandra
    JOURNAL OF HAND AND MICROSURGERY, 2012, 4 (02) : 55 - 59
  • [5] Evaluation of the effect of ultrasound guidance on the accuracy of intercostal nerve injection: a canine cadaveric study
    Thomson, Alexander C. S.
    Portela, Diego A.
    Romano, Marta
    Otero, Pablo E.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2021, 48 (02) : 256 - 263
  • [6] Accuracy of Two Ultrasound-Guided Coracohumeral Ligament Injection Approaches: A Cadaveric Study
    Majdalani, Carl
    Boudier-Reveret, Mathieu
    Pape, John
    Brismee, Jean-Michel
    Michaud, Johan
    Luong, Dien Hung
    Grabs, Detlev
    Chang, Ke-Vin
    Chen, Wen-Shiang
    Wu, Chueh Hung
    Sobczak, Stephane
    PM&R, 2019, 11 (09) : 989 - 995
  • [7] Accuracy of the Glenohumeral Injection Using the Superior Approach A Cadaveric Study of Injection Accuracy
    Kim, Joon-Sung
    Yun, Jong Soo
    Kim, Jae Min
    Ko, Young Jin
    Rhee, Won Ihl
    Ha, Nan Kyung
    Kim, Min-Wook
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2010, 89 (09) : 755 - 758
  • [8] THE FIRST DORSAL EXTENSOR COMPARTMENT - AN ANATOMIC STUDY
    GONZALEZ, MH
    SOHLBERG, R
    BROWN, A
    WEINZWEIG, N
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1995, 20A (04): : 657 - 660
  • [9] Anatomic location of the first dorsal extensor compartment for surgical De-Quervain's tenosynovitis release: A cadaveric study
    Thandoni, Aditya
    Yetter, William Nicholas
    Regal, Steven Michael
    WORLD JOURNAL OF ORTHOPEDICS, 2024, 15 (04): : 379 - 385
  • [10] Injection of tennis elbow: Hit and miss? A cadaveric study of injection accuracy
    Renée Keijsers
    Michel P. J. van den Bekerom
    Koen L. M. Koenraadt
    Ronald L. A. W. Bleys
    C. Niek van Dijk
    Denise Eygendaal
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 2289 - 2292