Accuracy of Two Ultrasound-Guided Coracohumeral Ligament Injection Approaches: A Cadaveric Study

被引:4
|
作者
Majdalani, Carl [1 ]
Boudier-Reveret, Mathieu [1 ]
Pape, John [2 ]
Brismee, Jean-Michel [3 ]
Michaud, Johan [1 ]
Luong, Dien Hung [1 ]
Grabs, Detlev [4 ,5 ]
Chang, Ke-Vin [6 ]
Chen, Wen-Shiang [6 ]
Wu, Chueh Hung [6 ]
Sobczak, Stephane [4 ,5 ]
机构
[1] Ctr Hosp Univ Montreal, Dept Phys Med & Rehabil, Montreal, PQ, Canada
[2] Univ Hosp North Tees, Dept Physiotherapy, Stockton On Tees, England
[3] Texas Tech Univ, Hlth Sci Ctr, Sch Hlth Profess, Ctr Rehabil Res, Lubbock, TX 79430 USA
[4] Univ Quebec Trois Rivieres, Dept Anat, Quebec City, PQ, Canada
[5] Univ Quebec Trois Rivieres, Res Unit Clin & Funct Anat, Quebec City, PQ, Canada
[6] Natl Taiwan Univ Hosp, Dept Phys Med & Rehabil, Taipei, Taiwan
关键词
ADHESIVE CAPSULITIS; FROZEN SHOULDER; CORTICOSTEROID INJECTION; ROTATOR INTERVAL; ANATOMY; CONTRACTURE; RELEASE;
D O I
10.1002/pmrj.12079
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background Glenohumeral idiopathic adhesive capsulitis is a common shoulder condition that hinders functionality. Addressing the pathology has been extensively researched. Ultrasound (US)-guided injections have shown their efficacy. However, no study has been conducted to compare anatomical accuracy between different approaches in targeting the coracohumeral ligament (CHL). Objective To investigate whether US-guided injection of the CHL can be performed accurately using either the rotator interval (RI) or the coracoidal (CO) approach. Methods An experimental cadaveric case series. Setting Anatomy laboratory. Specimens Both shoulders of 13 Thiel-embalmed cadavers. Interventions Three physiatrists each injected a 0.1 mL bolus of colored dye in both shoulders of each cadaver using either the RI or the CO approach under US guidance. Each cadaver received a total of six injections (three injections per shoulder). The accuracy of the injection was determined following shoulder dissection by an anatomist. Main Outcome Measure The accuracy of the US-guided injection of the CHL. Results The RI approach yielded 36 accurate injections, giving it an accuracy of 100%. With the CO approach two injections were deemed inaccurate yielding an accuracy of 94%. There was no significant difference in accuracy between all operators. Conclusions US-guided injection of the CHL can be performed accurately with both the RI and CO approaches. The RI approach was likely to be more accurate.
引用
收藏
页码:989 / 995
页数:7
相关论文
共 50 条
  • [1] Ultrasound-guided coracohumeral ligament release
    Yukata, K.
    Goto, T.
    Sakai, T.
    Fujii, H.
    Hamawaki, J.
    Yasui, N.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (06) : 823 - 827
  • [2] Accuracy of unguided and ultrasound guided Coracohumeral ligament infiltrations - a feasibility cadaveric case series
    Pape, John L.
    Boudier-Reveret, Mathieu
    Brismee, Jean-Michel
    Gilbert, Kerry K.
    Grabs, Detlev
    Sobczak, Stephane
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [3] Accuracy of unguided and ultrasound guided Coracohumeral ligament infiltrations – a feasibility cadaveric case series
    John L. Pape
    Mathieu Boudier-Revéret
    Jean-Michel Brismée
    Kerry K. Gilbert
    Detlev Grabs
    Stéphane Sobczak
    BMC Musculoskeletal Disorders, 21
  • [4] Landmark-Guided and Ultrasound-Guided Approaches for Trochanteric Bursa Injection: A Cadaveric Study
    Mu, Alex
    Peng, Philip
    Agur, Anne
    ANESTHESIA AND ANALGESIA, 2017, 124 (03): : 966 - 971
  • [5] Accuracy of Ultrasound-Guided Genicular Nerve Block: A Cadaveric Study
    Yasar, Evren
    Kesikburun, Serdar
    Kilic, Cenk
    Guzelkucuk, Umut
    Yazar, Fatih
    Tan, Arif Kenan
    PAIN PHYSICIAN, 2015, 18 (05) : E899 - E904
  • [6] Ultrasound-guided thoracic paravertebral injection in dogs: a cadaveric study
    Portela, Diego A.
    Campoy, Luis
    Otero, Pablo E.
    Martin-Flores, Manuel
    Gleed, Robin D.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2017, 44 (03) : 636 - 645
  • [7] Accuracy of ultrasound-guided intra-articular injection of cervical facet joints in horses: a cadaveric study
    Nielsen, JV
    Berg, LC
    Thoefner, MB
    Thomsen, PD
    EQUINE VETERINARY JOURNAL, 2003, 35 (07) : 657 - 661
  • [8] A Cadaveric Study Assessing the Accuracy of Ultrasound-Guided Sacroiliac Joint Injections
    Perry, Jason M.
    Colberg, Ricardo E.
    Dault, Stacey L.
    Beason, David P.
    Tresgallo, Ruben A.
    PM&R, 2016, 8 (12) : 1168 - 1172
  • [9] Ultrasound-Guided Injection of the Sternocleidomastoid Muscle: A Cadaveric Study with Implications for Chemodenervation
    Kim, Beom Suk
    Kim, Da Som
    Kang, Seok
    Kim, Jae Young
    Kang, Byungheon
    Rhyu, Im Joo
    Yoon, Joon Shik
    PM&R, 2021, 13 (05) : 503 - 509
  • [10] Ultrasound-guided injection of the achilles paratenon: A cadaveric investigation
    Ricci, Vincenzo
    Mezian, Kamal
    Chang, Ke-Vin
    Tamborrini, Giorgio
    Jacisko, Jakub
    Nanka, Ondrej
    Ozcakar, Levent
    FOOT AND ANKLE SURGERY, 2024, 30 (04) : 313 - 318