Accuracy of Injection Into the First Dorsal Compartment: A Cadaveric Ultrasound Study

被引:9
|
作者
Kutsikovich, Jeffrey [1 ]
Merrell, Gregory [1 ]
机构
[1] Indiana Hand Shoulder Ctr, 8501 Harcourt Rd, Indianapolis, IN 46260 USA
来源
关键词
de Quervain; injection; ultrasound; QUERVAINS; TENOSYNOVITIS; SEPTUM;
D O I
10.1016/j.jhsa.2018.01.020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To determine the accuracy of ultrasound-guided (UG) injections compared with anatomic landmark-guided (AL) injections in the first dorsal compartment (FDC) with the hypothesis that ultrasound guidance would increase the accuracy of injection. Methods We randomized 43 above-elbow cadaveric specimens to receive latex dye injections into the FDC via a UG or AL technique. If ultrasound imaging identified a septated FDC, the needle was redirected and a portion of the dye was injected around the extensor pollicis brevis (EPB) tendon. Specimens were dissected and data collected regarding the location of the dye and presence of a septated FDC. Fisher exact test was used to calculate the difference in accuracy rates of injections. Results All 21 specimens injected via UG and all 22 specimens injected via the AL technique demonstrated dye within the FDC. Eight of 21 specimens in the UG group and 6 of 22 specimens in the AL group demonstrated a septated FDC upon dissection. Ultrasound was able to identify 6 of 8 specimens accurately with a septated FDC, representing a sensitivity of 75% and specificity of 92%. Six of 8 specimens with a septated FDC in the UG group versus 2 of 6 specimens with a septated FDC in the AL group demonstrated dye infiltration around the EPB. Dye was noted in the subcutaneous tissues in 2 of 21 specimens in the UG group versus 2 of 22 specimens in the AL group. Conclusions The UG-and AL-based injections both had excellent dye infiltration into a portion of the FDC. Ultrasound-guided injections had a higher observed infiltration rate in EPB sub-compartments than the AL technique, but could not be statistically confirmed to be different. Copyright (C) 2018 by the American Society for Surgery of the Hand. All rights reserved.
引用
收藏
页码:777.e1 / 777.e5
页数:5
相关论文
共 50 条
  • [31] Ultrasound-Guided First Dorsal Compartment Release for Refractory de Quervain Tenosynovitis: A Case Report
    Colberg, Ricardo E.
    Henderson, Rachel G.
    PM&R, 2019, 11 (06) : 665 - 668
  • [32] Ultrasound-Guided Injection of the Sternocleidomastoid Muscle: A Cadaveric Study with Implications for Chemodenervation
    Kim, Beom Suk
    Kim, Da Som
    Kang, Seok
    Kim, Jae Young
    Kang, Byungheon
    Rhyu, Im Joo
    Yoon, Joon Shik
    PM&R, 2021, 13 (05) : 503 - 509
  • [33] A mimic of first dorsal interosseus atrophy revealed by ultrasound study
    Ginanneschi, Federica
    Filippou, Georgios
    Ulivelli, Monica
    Mignarri, Andrea
    Rossi, Alessandro
    CLINICAL NEUROPHYSIOLOGY, 2015, 126 (02) : 423 - 424
  • [34] Accuracy of Ultrasound-Guided and Non-guided Botulinum Toxin Injection Into Neck Muscles Involved in Cervical Dystonia: A Cadaveric Study
    Ko, Yun Dam
    Yun, Soo In
    Ryoo, Dahye
    Chung, Myung Eun
    Park, Jihye
    ANNALS OF REHABILITATION MEDICINE-ARM, 2020, 44 (05): : 370 - 377
  • [35] A cadaveric study of the innervation of the anterior compartment of the knee
    Suresh, Rachana
    Buddhiraju, Anirudh
    Kuo, Keith
    Dellon, A. Lee
    Tuffaha, Sami
    Williams, Eric
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2025, 145 (01)
  • [36] Ultrasound Accuracy of Liver Length Measurement With Cadaveric Specimens
    Riestra-Candelaria, Barbara L.
    Rodriguez-Mojica, Wilma
    Vazquez-Quinones, Luis E.
    Jorge, Juan Carlos
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2016, 32 (01) : 12 - 19
  • [37] Assessment of penetration of dorsal screws after fixation of the distal radius using ultrasound: cadaveric study
    Williams, D.
    Singh, J.
    Heidari, N.
    Ahmad, M.
    Noorani, A.
    Di Mascio, L.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2016, 98 (02) : 138 - 142
  • [38] A Cadaveric Study of Injectate Spread in the Psoas Compartment With a Direct Iliopsoas Injection Suggested for Use During Surgery
    Green, Connor
    Flannery, Olivia
    Crotty, Jim
    Felle, Patrick
    Harmon, Dominic
    Masterson, Eric
    CLINICAL ANATOMY, 2011, 24 (06) : 763 - 767
  • [39] Ultrasound-guided injection for De Quervain's disease: Accuracy and its influenceable anatomical variances in first extensor compartment of fresh cadaver wrists
    Kang, Jong Woo
    Park, Jong Woong
    Lee, Soon Hyuck
    Park, Jong Hoon
    Han, Seung Bum
    Park, Si Young
    Jeong, Woong Kyo
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2017, 22 (02) : 270 - 274
  • [40] Anatomical study of the first dorsal extensor compartment for the treatment of de Quervain's disease
    Nam, Yong Seok
    Doh, GyeongHyeon
    Hong, Ki Yong
    Lim, SooA
    Eo, SuRak
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2018, 218 : 250 - 255