X-ray vector radiography of a human hand

被引:0
|
作者
Jud, Christoph [1 ,2 ]
Braig, Eva [1 ,2 ,3 ]
Dierolf, Martin [1 ,2 ]
Eggl, Elena [1 ,2 ]
Guenther, Benedikt [1 ,2 ,4 ]
Achterhold, Klaus [1 ,2 ]
Gleich, Bernhard [1 ,2 ]
Rummeny, Ernst [3 ]
Noel, Peter [3 ]
Pfeiffer, Franz [1 ,2 ,3 ,5 ]
Muenzel, Daniela [3 ]
机构
[1] Tech Univ Munich, Chair Biomed Phys, Dept Phys, D-85748 Garching, Germany
[2] Tech Univ Munich, Munich Sch Bioengn, D-85748 Garching, Germany
[3] Tech Univ Munich, Dept Diagnost & Intervent Radiol, Klinikum Rechts Isar, D-81675 Munich, Germany
[4] Max Planck Inst Quantum Opt, D-85748 Garching, Germany
[5] Tech Univ Munich, Inst Adv Study, D-85748 Garching, Germany
基金
欧洲研究理事会;
关键词
X-ray vector radiography; bone microfractures; x-ray phase-contrast; Talbot grating interferometry; DIFFERENTIAL PHASE-CONTRAST; SYNCHROTRON LIGHT-SOURCE; TOMOGRAPHY;
D O I
10.1117/12.2255595
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Grating based x-ray phase-contrast reveals differential phase-contrast (DPC) and dark-field contrast (DFC) on top of the conventional absorption image. X-ray vector radiography (XVR) exploits the directional dependence of the DFC and yields the mean scattering strength, the degree of anisotropy and the orientation of scattering structures by combining several DFC-projections. Here, we perform an XVR of an ex vivo human hand specimen. Conventional attenuation images have a good contrast between the bones and the surrounding soft tissue. Within the bones, trabecular structures are visible. However, XVR detects subtler differences within the trabecular structure: there is isotropic scattering in the extremities of the phalanx in contrast to anisotropic scattering in its body. The orientation changes as well from relatively random in the extremities to an alignment along the longitudinal trabecular orientation in the body. In the other bones measured, a similar behavior was found. These findings indicate a deeper insight into the anatomical configuration using XVR compared to conventional radiography. Since microfractures cause a discontinuous trabecular structure, XVR could help to detect so-called radiographically occult fractures of the trabecular bones.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Analysis of X-ray radiography in atomizing sprays
    Linne, Mark
    EXPERIMENTS IN FLUIDS, 2012, 53 (03) : 655 - 671
  • [32] X-RAY RADIOGRAPHY OF RECENT CARBONATE SEDIMENTS
    ROBERTS, HH
    JOURNAL OF SEDIMENTARY PETROLOGY, 1972, 42 (03): : 690 - &
  • [33] A new X-ray scintillator for digital radiography
    Nagarkar, VV
    Tipnis, SV
    Miller, SR
    Lempicki, A
    Brecher, C
    Szupryczynski, P
    Lingertat, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (03) : 297 - 300
  • [34] Computed radiography X-ray exposure trends
    Seibert, JA
    Shelton, DK
    Moore, EH
    ACADEMIC RADIOLOGY, 1996, 3 (04) : 313 - 318
  • [35] Analysis of X-ray radiography in atomizing sprays
    Mark Linne
    Experiments in Fluids, 2012, 53 : 655 - 671
  • [36] COMPENSATED X-RAY ATTENUATION IN SKULL RADIOGRAPHY
    CABANIS, EA
    MAUGIS, A
    METZGER, J
    PERILHOU, J
    JOURNAL OF NEURORADIOLOGY, 1979, 6 (03) : 255 - 267
  • [37] Optimization tool for x-ray radiography NDE
    Elshafiey, I
    Gray, JN
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 15A AND 15B, 1996, 15 : 425 - 432
  • [38] X-RAY BEAM PROFILES AND ORAL RADIOGRAPHY
    WEISSMAN, DD
    FEINSTEIN, RB
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1971, 31 (04): : 546 - +
  • [39] A new x-ray scintillator for digital radiography
    Nagarkar, VV
    Tipnis, SV
    Miller, SR
    Lempicki, A
    Brecher, C
    Szupryczynski, P
    Lingertat, H
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 134 - 137
  • [40] X-ray phase-contrast radiography
    Wilkins, SW
    Gao, D
    Gureyev, T
    Pogany, A
    Stevenson, AW
    RADIOLOGY, 1997, 205 : 907 - 907