X-ray vector radiography of a human hand

被引:0
|
作者
Jud, Christoph [1 ,2 ]
Braig, Eva [1 ,2 ,3 ]
Dierolf, Martin [1 ,2 ]
Eggl, Elena [1 ,2 ]
Guenther, Benedikt [1 ,2 ,4 ]
Achterhold, Klaus [1 ,2 ]
Gleich, Bernhard [1 ,2 ]
Rummeny, Ernst [3 ]
Noel, Peter [3 ]
Pfeiffer, Franz [1 ,2 ,3 ,5 ]
Muenzel, Daniela [3 ]
机构
[1] Tech Univ Munich, Chair Biomed Phys, Dept Phys, D-85748 Garching, Germany
[2] Tech Univ Munich, Munich Sch Bioengn, D-85748 Garching, Germany
[3] Tech Univ Munich, Dept Diagnost & Intervent Radiol, Klinikum Rechts Isar, D-81675 Munich, Germany
[4] Max Planck Inst Quantum Opt, D-85748 Garching, Germany
[5] Tech Univ Munich, Inst Adv Study, D-85748 Garching, Germany
基金
欧洲研究理事会;
关键词
X-ray vector radiography; bone microfractures; x-ray phase-contrast; Talbot grating interferometry; DIFFERENTIAL PHASE-CONTRAST; SYNCHROTRON LIGHT-SOURCE; TOMOGRAPHY;
D O I
10.1117/12.2255595
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Grating based x-ray phase-contrast reveals differential phase-contrast (DPC) and dark-field contrast (DFC) on top of the conventional absorption image. X-ray vector radiography (XVR) exploits the directional dependence of the DFC and yields the mean scattering strength, the degree of anisotropy and the orientation of scattering structures by combining several DFC-projections. Here, we perform an XVR of an ex vivo human hand specimen. Conventional attenuation images have a good contrast between the bones and the surrounding soft tissue. Within the bones, trabecular structures are visible. However, XVR detects subtler differences within the trabecular structure: there is isotropic scattering in the extremities of the phalanx in contrast to anisotropic scattering in its body. The orientation changes as well from relatively random in the extremities to an alignment along the longitudinal trabecular orientation in the body. In the other bones measured, a similar behavior was found. These findings indicate a deeper insight into the anatomical configuration using XVR compared to conventional radiography. Since microfractures cause a discontinuous trabecular structure, XVR could help to detect so-called radiographically occult fractures of the trabecular bones.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] The hand X-ray in rheumatology
    Kassimos, D
    Creamer, P
    HOSPITAL MEDICINE, 2004, 65 (01): : 13 - 17
  • [22] VALUE OF X-RAY FILMS OF HAND AND WRIST IN HUMAN IDENTIFICATION
    GREULICH, WW
    SCIENCE, 1960, 131 (3394) : 155 - 156
  • [23] X-ray backscatter radiography - Intrusive instead of penetrating, X-ray shadow phenomenon
    Wrobel, Norma
    Kolkoori, Sanjeevareddy
    Osterloh, Kurt
    MATERIALS TESTING, 2013, 55 (09) : 689 - 693
  • [24] X-ray induced pinhole closure in point-projection x-ray radiography
    Bullock, A. B.
    Landen, O. L.
    Blue, B. E.
    Edwards, J.
    Bradley, D. K.
    JOURNAL OF APPLIED PHYSICS, 2006, 100 (04)
  • [25] Developoment of flash X-ray radiography and X-ray fluorescence imaging for characterization of fluids
    Robert, E
    Huré, L
    Cachoncinlle, C
    Viladrosa, R
    Pouvesle, JM
    JOURNAL DE PHYSIQUE IV, 2001, 11 (PR7): : 171 - 174
  • [26] Hollow anode valves for x-ray radiography
    Muller, EAW
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1937, 81 : 1175 - 1175
  • [27] Image enhancement for X-ray digital radiography
    Chen, SY
    Lu, XZ
    Lu, HN
    ISTM/99: 3RD INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, 1999, : 587 - 589
  • [28] X-ray Digital Radiography and Computed Tomography
    Morigi, Maria Pia
    Albertin, Fauzia
    JOURNAL OF IMAGING, 2022, 8 (05)
  • [29] Improved radiography with polycapillary x-ray optics
    MacDonald, CA
    Sugiro, FR
    Gibson, WM
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES AND OPTICS II, 2001, 4502 : 10 - 18
  • [30] Integrated system simulation in X-ray radiography
    Kwan, TJT
    Mathews, AR
    Christenson, PJ
    Snell, CM
    COMPUTER PHYSICS COMMUNICATIONS, 2001, 142 (1-3) : 263 - 269