Corneal power measurement with a rotating Scheimpflug imaging system after Descemet-stripping automated endothelial keratoplasty

被引:13
|
作者
Prasher, Pawan [1 ]
Muftuoglu, Orkun [1 ]
Bowman, R. Wayne [1 ]
Cavanagh, H. Dwight [1 ]
McCulley, James P. [1 ]
Mootha, V. Vinod [1 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Ophthalmol, Dallas, TX 75390 USA
来源
关键词
INTRAOCULAR-LENS IMPLANTATION; PENTACAM; CAMERA; SHIFT; EYES;
D O I
10.1016/j.jcrs.2010.01.032
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate alterations in corneal power parameters after Descemet-stripping automated endothelial keratoplasty (DSAEK) using rotating Scheimpflug imaging. SETTING: University of Texas, Southwestern Medical Center, Dallas, Texas, USA. METHODS: Eyes that had DSAEK were evaluated with a rotating Scheimpflug imaging system (Pentacam). The outcome parameters were mean anterior and posterior keratometry (K), mean anterior radius of curvature and posterior radius of curvature, anterior and posterior astigmatism, central corneal thickness (CCT), true net power, corneal volume, keratometric power deviation, and mean zonal-equivalent K readings. These values were compared with those in a control group of age and sex-matched normal eyes. RESULTS: The DSAEK group comprised 32 eyes (28 patients) and the control group, 32 eyes. The mean anterior K, posterior K, and true net power were 42.53 diopters (D) +/- 1.52 (SD), -6.80 +/- 0.55 D, and 40.55 +/- 1.79 D, respectively, in the DSAEK group and 43.60 +/- 1.62 D, -6.20 +/- 0.31 D, and 42.49 +/- 1.57 D, respectively, in the control group. The posterior radius of curvature, anterior and posterior K values, and true net power were statistically significantly lower in DSAEK eyes than in control eyes (P<.01). The equivalent K readings were significantly lower in all zones in DSAEK eyes than in control eyes (P<.01). The mean CCT was significantly higher in DSAEK eyes than in control eyes (628 +/- 46 mu m versus 553 +/- 35 mu m) (P<.01). CONCLUSION: The true net power of the cornea decreased significantly after DSAEK, mainly because of an increase in posterior curvature.
引用
收藏
页码:1358 / 1364
页数:7
相关论文
共 50 条
  • [41] Severe Corneal Hydrops With Suspected Posterior Stromal Rupture Managed With Ultrathin Descemet-Stripping Automated Endothelial Keratoplasty
    Blitzer, Andrea L.
    Liles, Caleb A.
    Harocopos, George J.
    Reidy, James J.
    Farooq, Asim, V
    CORNEA, 2021, 40 (04) : 513 - 515
  • [42] Corneal Graft Detachment Without Corneal Edema After Descemet Stripping Automated Endothelial Keratoplasty
    Zafirakis, Panayotis
    Kymionis, George D.
    Grentzelos, Michael A.
    Livir-Rallatos, Gerasimos
    CORNEA, 2010, 29 (04) : 456 - 458
  • [43] Corneal clarity restoration after Descemet stripping automated endothelial keratoplasty with edematous corneal graft
    Kymionis, George D.
    Kontadakis, Georgios A.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2011, 21 (06) : 830 - 833
  • [44] Factors Influencing Corneal Endothelial Cell Density after Descemet Stripping Automated Endothelial Keratoplasty
    Park, Chanjoon
    Yoon, Hye Yeon
    Kim, Hyun Seung
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2024, 65 (11): : 699 - 707
  • [45] Quality of Endothelial Images Acquired by Three Methods After Descemet-Stripping With Endothelial Keratoplasty
    Raecker, M. E.
    Kittleson, K. M.
    McLaren, J. W.
    Patel, S. V.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [46] Primary graft failure after Descemet-stripping automated endothelial keratoplasty - Clinico-pathological study
    Mehta, Jodhbir Singh
    Chua, Jocelyn
    Poh, Rehekah
    Beuerman, Roger Wilmer
    Tan, Donald
    CORNEA, 2008, 27 (06) : 722 - 726
  • [47] Chandelier illumination to complete Descemet stripping through severe hazy cornea during Descemet-stripping automated endothelial keratoplasty
    Inoue, Tomoyuki
    Oshima, Yusuke
    Shima, Chiharu
    Hori, Yuichi
    Maeda, Naoyuki
    Tano, Yasuo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (06): : 892 - 896
  • [48] Refractory Recurrent Corneal Erosion after Descemet's Stripping Automated Endothelial Keratoplasty
    Kim, Minjeong
    Oh, Ja Young
    Kim, Kyoung Woo
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2022, 63 (01): : 94 - 100
  • [49] Descemet stripping automated endothelial keratoplasty
    Sharma, Namrata
    Maharana, Prafulla K.
    Singhi, Shipra
    Aron, Neelima
    Patil, Mukesh
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (03) : 198 - 209
  • [50] Descemet-stripping automated endothelial keratoplasty in eyes with toxic anterior segment syndrome after cataract surgery
    Arslan, Osman S.
    Unal, Mustafa
    Arici, Ceyhun
    Gorgun, Ebru
    Yenerel, Melda
    Cicik, Erdogan
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (06): : 965 - 969