Corneal power measurement with a rotating Scheimpflug imaging system after Descemet-stripping automated endothelial keratoplasty

被引:13
|
作者
Prasher, Pawan [1 ]
Muftuoglu, Orkun [1 ]
Bowman, R. Wayne [1 ]
Cavanagh, H. Dwight [1 ]
McCulley, James P. [1 ]
Mootha, V. Vinod [1 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Ophthalmol, Dallas, TX 75390 USA
来源
关键词
INTRAOCULAR-LENS IMPLANTATION; PENTACAM; CAMERA; SHIFT; EYES;
D O I
10.1016/j.jcrs.2010.01.032
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate alterations in corneal power parameters after Descemet-stripping automated endothelial keratoplasty (DSAEK) using rotating Scheimpflug imaging. SETTING: University of Texas, Southwestern Medical Center, Dallas, Texas, USA. METHODS: Eyes that had DSAEK were evaluated with a rotating Scheimpflug imaging system (Pentacam). The outcome parameters were mean anterior and posterior keratometry (K), mean anterior radius of curvature and posterior radius of curvature, anterior and posterior astigmatism, central corneal thickness (CCT), true net power, corneal volume, keratometric power deviation, and mean zonal-equivalent K readings. These values were compared with those in a control group of age and sex-matched normal eyes. RESULTS: The DSAEK group comprised 32 eyes (28 patients) and the control group, 32 eyes. The mean anterior K, posterior K, and true net power were 42.53 diopters (D) +/- 1.52 (SD), -6.80 +/- 0.55 D, and 40.55 +/- 1.79 D, respectively, in the DSAEK group and 43.60 +/- 1.62 D, -6.20 +/- 0.31 D, and 42.49 +/- 1.57 D, respectively, in the control group. The posterior radius of curvature, anterior and posterior K values, and true net power were statistically significantly lower in DSAEK eyes than in control eyes (P<.01). The equivalent K readings were significantly lower in all zones in DSAEK eyes than in control eyes (P<.01). The mean CCT was significantly higher in DSAEK eyes than in control eyes (628 +/- 46 mu m versus 553 +/- 35 mu m) (P<.01). CONCLUSION: The true net power of the cornea decreased significantly after DSAEK, mainly because of an increase in posterior curvature.
引用
收藏
页码:1358 / 1364
页数:7
相关论文
共 50 条
  • [31] Descemet Stripping Automated Endothelial Keratoplasty versus Descemet Membrane Endothelial Keratoplasty for Fuchs Endothelial Corneal Dystrophy
    Viberg, Andreas
    Samolov, Branka
    Bystroem, Berit
    OPHTHALMOLOGY, 2023, 130 (12) : 1248 - 1257
  • [32] Retained nuclear fragment found during Descemet-stripping automated endothelial keratoplasty
    Mifflin, Mark D.
    Neuffer, Marcus C.
    Mamalis, Nick
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (03): : 608 - 610
  • [33] Corneal biomechanical changes after Descemet stripping automated endothelial keratoplasty, penetrating keratoplasty, and phacoemulsification
    Rahimi, Mahnaz
    Bazaz, Mahmoodreza Panahi
    Sharifipour, Farideh
    Hajizadeh, Maryam
    Cheraghian, Bahman
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (10) : 3183 - 3190
  • [34] Keratocyte Density After Descemet-Stripping With Endothelial Keratoplasty for Fuchs' Endothelial Dystrophy
    Kittleson, K. M.
    McLaren, J. W.
    Patel, S. V.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [35] Visual quality assessment after DSAEK corneal keratoplasty (Descemet Stripping Automated Endothelial Keratoplasty)
    Guechi, Oualid
    Boiche, Mathilde
    Yahia, Rekia
    Ghetemme, Cedric
    Houmad, Naila
    Baudot, Audrey
    Ameloot, Francois
    Perone, Jean-Marc
    Bertaux, Pierre-jean
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [36] Corneal biomechanical changes after Descemet stripping automated endothelial keratoplasty, penetrating keratoplasty, and phacoemulsification
    Mahnaz Rahimi
    Mahmoodreza Panahi Bazaz
    Farideh Sharifipour
    Maryam Hajizadeh
    Bahman Cheraghian
    International Ophthalmology, 2022, 42 : 3183 - 3190
  • [37] Regression of severe corneal neovascularization after a triple procedure Phacoemulsification, intraocular lens implantation, and Descemet-stripping automated endothelial keratoplasty
    Hadayer, Amir
    Kleinmann, Guy
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (05): : 831 - 832
  • [38] Corneal endothelial viability after femtosecond laser preparation of posterior lamellar discs for Descemet-stripping endothelial keratoplasty
    Cheng, Yanny Y. Y.
    Pels, Elisabeth
    Cleutjens, Jack P. M.
    van Suylen, Robert J.
    Hendrikse, Fred
    Nuijts, Rudy M. M. A.
    CORNEA, 2007, 26 (09) : 1118 - 1122
  • [39] Modified air-assisted descemetorhexis for Descemet-stripping automated endothelial keratoplasty
    Mehta, Jodhbir S.
    Hantera, Mohammed M.
    Tan, Donald T.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (06): : 889 - 891
  • [40] Stability of hyperopic refractive shift following Descemet-stripping automated endothelial keratoplasty
    Chen, Edwin S.
    Terry, Mark A.
    Shamie, Neda
    Hoar, Karen L.
    Friend, Daniel J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (08): : 1473 - 1473