Corneal power measurement with a rotating Scheimpflug imaging system after Descemet-stripping automated endothelial keratoplasty

被引:13
|
作者
Prasher, Pawan [1 ]
Muftuoglu, Orkun [1 ]
Bowman, R. Wayne [1 ]
Cavanagh, H. Dwight [1 ]
McCulley, James P. [1 ]
Mootha, V. Vinod [1 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Ophthalmol, Dallas, TX 75390 USA
来源
关键词
INTRAOCULAR-LENS IMPLANTATION; PENTACAM; CAMERA; SHIFT; EYES;
D O I
10.1016/j.jcrs.2010.01.032
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate alterations in corneal power parameters after Descemet-stripping automated endothelial keratoplasty (DSAEK) using rotating Scheimpflug imaging. SETTING: University of Texas, Southwestern Medical Center, Dallas, Texas, USA. METHODS: Eyes that had DSAEK were evaluated with a rotating Scheimpflug imaging system (Pentacam). The outcome parameters were mean anterior and posterior keratometry (K), mean anterior radius of curvature and posterior radius of curvature, anterior and posterior astigmatism, central corneal thickness (CCT), true net power, corneal volume, keratometric power deviation, and mean zonal-equivalent K readings. These values were compared with those in a control group of age and sex-matched normal eyes. RESULTS: The DSAEK group comprised 32 eyes (28 patients) and the control group, 32 eyes. The mean anterior K, posterior K, and true net power were 42.53 diopters (D) +/- 1.52 (SD), -6.80 +/- 0.55 D, and 40.55 +/- 1.79 D, respectively, in the DSAEK group and 43.60 +/- 1.62 D, -6.20 +/- 0.31 D, and 42.49 +/- 1.57 D, respectively, in the control group. The posterior radius of curvature, anterior and posterior K values, and true net power were statistically significantly lower in DSAEK eyes than in control eyes (P<.01). The equivalent K readings were significantly lower in all zones in DSAEK eyes than in control eyes (P<.01). The mean CCT was significantly higher in DSAEK eyes than in control eyes (628 +/- 46 mu m versus 553 +/- 35 mu m) (P<.01). CONCLUSION: The true net power of the cornea decreased significantly after DSAEK, mainly because of an increase in posterior curvature.
引用
收藏
页码:1358 / 1364
页数:7
相关论文
共 50 条
  • [1] Descemet-stripping automated endothelial keratoplasty
    Gorovoy, Mark S.
    CORNEA, 2006, 25 (08) : 886 - 889
  • [2] Descemet-Stripping Automated Endothelial Keratoplasty
    Gorovoy, Mark S.
    CORNEA, 2021, 40 (03) : 270 - 273
  • [3] Epithelial ingrowth after Descemet-stripping automated endothelial keratoplasty
    Koenig, Steven B.
    Covert, Douglas J.
    CORNEA, 2008, 27 (06) : 727 - 729
  • [4] Epithelial downgrowth after Descemet-stripping automated endothelial keratoplasty
    Phillips, Paul M.
    Terry, Mark A.
    Kaufman, Stephen C.
    Chen, Edwin S.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (01): : 193 - 196
  • [5] Guttae in the donor after Descemet-stripping automated endothelial keratoplasty
    Lee, Bryan S.
    Virdi, Ajoy S.
    Hammersmith, Kristin M.
    Jun, Albert S.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (10) : 1523 - 1525
  • [6] Guttae in the donor after Descemet-stripping automated endothelial keratoplasty
    Bryan S. Lee
    Ajoy S. Virdi
    Kristin M. Hammersmith
    Albert S. Jun
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 1523 - 1525
  • [7] Changes in Corneal Power After Descemet Stripping Automated Endothelial Keratoplasty
    Clemmensen, Kare
    Ivarsen, Anders
    Hjortdal, Jesper
    JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (12) : 807 - 812
  • [8] Descemet-stripping Automated Endothelial Keratoplasty Effect of Anterior Lamellar Corneal Tissue-On/-Off Storage Condition on Descemet-stripping Automated Endothelial Keratoplasty Donor Tissue
    Ide, Takeshi
    Yoo, Sonia H.
    Kymionis, George D.
    Goldman, James M.
    Perez, Victor L.
    O'Brien, Terrence P.
    CORNEA, 2008, 27 (07) : 754 - 757
  • [9] Ischemic optic neuropathy after Descemet-stripping automated endothelial keratoplasty
    Rosenberg, Christopher R.
    Weissbart, Sarah B.
    Sibony, Patrick A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (12): : E8 - E10
  • [10] Descemet-stripping automated endothelial keratoplasty after bee sting of the cornea
    Hammel, Na'ama
    Bahar, Irit
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (09): : 1726 - 1728