Interest of intra-operative 3D imaging in spine surgery: a prospective randomized study

被引:17
|
作者
Ruatti, Sebastien [1 ]
Dubois, C. [2 ]
Chipon, E. [3 ]
Kerschbaumer, G. [1 ]
Milaire, M. [1 ]
Moreau-Gaudry, A. [3 ]
Tonetti, J. [1 ]
Merloz, Ph. [1 ]
机构
[1] CHU A Michallon, Univ Dept Orthopaed Surg & Traumatol, F-38043 Grenoble, France
[2] CHU A Michallon, Univ Dept Med Imaging, F-38043 Grenoble, France
[3] Univ Grenoble 1, Clin Invest & Technol Innovat Ctr CIC IT, F-38043 Grenoble, France
关键词
Spine surgery; 3D imaging; Computer-aided surgery; Navigation and spine surgery; 3D fluoroscope; PEDICLE SCREW PLACEMENT; COMPUTED-TOMOGRAPHY; NAVIGATION SYSTEM; LUMBAR SPINE; IN-VIVO; ACCURACY; FLUOROSCOPY; INSERTION; GUIDANCE; EXPOSURE;
D O I
10.1007/s00586-015-4141-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We report a single-center, prospective, randomized study for pedicle screw insertion in opened and percutaneous spine surgeries, using a computer-assisted surgery (CAS) technique with three-dimensional (3D) intra-operative images intensifier (without planification on pre-operative CT scan) vs conventional surgical procedure. We included 143 patients: Group C (conventional, 72 patients) and Group N (3D Fluoronavigation, 71 patients). We measured the pedicle screw running time, and surgeon's radiation exposure. All pedicle runs were assessed according to Heary by two independent radiologists on a post-operative CT scan. 3D Fluoronavigation appeared less accurate in percutaneous procedures (24 % of misplaced pedicle screws vs 5 % in Group C) (p = 0.007), but more accurate in opened surgeries (5 % of misplaced pedicle screws vs 17 % in Group C) (p = 0.025). For one vertebra, the average surgical running time reached 8 min in Group C vs 21 min in Group N for percutaneous surgeries (p = 3.42 x 10(-9)), 7.33 min in Group C vs 16.33 min in Group N (p = 2.88 x 10(-7)) for opened surgeries. The 3D navigation device delivered less radiation in percutaneous procedures [0.6 vs 1.62 mSv in Group C (p = 2.45 x 10(-9))]. For opened surgeries, it was twice higher in Group N with 0.21 vs 0.1 mSv in Group C (p = 0.022). The rate of misplaced pedicle screws with conventional techniques was nearly the same as most papers and a little bit higher with CAS. Surgical running time and radiation exposure were consistent with many studies. Our work hypothesis is partially confirmed, depending on the type of surgery (opened or closed procedure).
引用
收藏
页码:1738 / 1744
页数:7
相关论文
共 50 条
  • [41] The Rationalisation of Intra-Operative Imaging During Cardiac Surgery: A Systematic Review
    Jaffar-Karballai, Mona
    Kayali, Fatima
    Botezatu, Bianca
    Satti, Danish Iltaf
    Harky, Amer
    HEART LUNG AND CIRCULATION, 2023, 32 (05): : 567 - 586
  • [42] Natural language processing for the automated detection of intra-operative elements in lumbar spine surgery
    Biswas, Sayan
    Mcmenemy, Lareyna
    Sarkar, Ved
    Macarthur, Joshua
    Snowdon, Ella
    Tetlow, Callum
    George, K. Joshi
    FRONTIERS IN SURGERY, 2023, 10
  • [43] Laser-pointing endoscope system for intra-operative 3D geometric registration
    Hayashibe, M
    Nakamura, Y
    2001 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS I-IV, PROCEEDINGS, 2001, : 1543 - 1548
  • [44] Diagnostic accuracy of 3D imaging combined with intra-operative ultrasound in the prediction of post-hepatectomy liver failure
    Wu, Tianchong
    Huang, Wenhao
    He, Baochun
    Guo, Yuehua
    Peng, Gongzhe
    Li, Mingyue
    Bao, Shiyun
    JOURNAL OF GASTROINTESTINAL ONCOLOGY, 2022, 13 (03) : 1224 - 1236
  • [45] 2D/3D registration of pre-operative CT images and intra-operative x-ray projections for image guided surgery
    Weese, J
    Penney, GP
    Buzug, TM
    Fassnacht, C
    Lorenz, C
    CAR '97 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1997, 1134 : 833 - 838
  • [46] 3-D Tomosynthesis for Intra-Operative Margin Assessment During Breast Conserving Surgery
    Black, D.
    Rauch, G.
    Leung, J.
    Park, C.
    Sahin, A.
    Kuerer, H. M.
    ANNALS OF SURGICAL ONCOLOGY, 2018, 25 : S95 - S95
  • [47] Interactive Initialization for 2D/3D Intra-Operative Registration using the Microsoft Kinect
    Gong, Ren Hui
    Gueler, Oezgur
    Yaniv, Ziv
    MEDICAL IMAGING 2013: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2013, 8671
  • [48] Correlation of pre-operative MRI and intra-operative 3D ultrasound to measure brain tissue shift
    Gobbi, DG
    Comeau, RM
    Lee, BKH
    Peters, TM
    MEDICAL IMAGING 2000: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2000, 3982 : 77 - 84
  • [49] Correlation of pre-operative MRI and intra-operative 3D ultrasound to measure brain tissue shift
    Gobbi, DG
    Lee, BKH
    Peters, TM
    MEDICAL IMAGING 2001: VISUALIZATION, DISPLAY, AND IMAGE-GUIDED PROCEDURES, 2001, 4319 : 264 - 271
  • [50] Prospective study of cervical HDR brachytherapy with intra-operative ultrasound guidance
    Korol, R. M.
    Surry, K. J. M.
    D'Souza, D. P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S368 - S368