Interest of intra-operative 3D imaging in spine surgery: a prospective randomized study

被引:17
|
作者
Ruatti, Sebastien [1 ]
Dubois, C. [2 ]
Chipon, E. [3 ]
Kerschbaumer, G. [1 ]
Milaire, M. [1 ]
Moreau-Gaudry, A. [3 ]
Tonetti, J. [1 ]
Merloz, Ph. [1 ]
机构
[1] CHU A Michallon, Univ Dept Orthopaed Surg & Traumatol, F-38043 Grenoble, France
[2] CHU A Michallon, Univ Dept Med Imaging, F-38043 Grenoble, France
[3] Univ Grenoble 1, Clin Invest & Technol Innovat Ctr CIC IT, F-38043 Grenoble, France
关键词
Spine surgery; 3D imaging; Computer-aided surgery; Navigation and spine surgery; 3D fluoroscope; PEDICLE SCREW PLACEMENT; COMPUTED-TOMOGRAPHY; NAVIGATION SYSTEM; LUMBAR SPINE; IN-VIVO; ACCURACY; FLUOROSCOPY; INSERTION; GUIDANCE; EXPOSURE;
D O I
10.1007/s00586-015-4141-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We report a single-center, prospective, randomized study for pedicle screw insertion in opened and percutaneous spine surgeries, using a computer-assisted surgery (CAS) technique with three-dimensional (3D) intra-operative images intensifier (without planification on pre-operative CT scan) vs conventional surgical procedure. We included 143 patients: Group C (conventional, 72 patients) and Group N (3D Fluoronavigation, 71 patients). We measured the pedicle screw running time, and surgeon's radiation exposure. All pedicle runs were assessed according to Heary by two independent radiologists on a post-operative CT scan. 3D Fluoronavigation appeared less accurate in percutaneous procedures (24 % of misplaced pedicle screws vs 5 % in Group C) (p = 0.007), but more accurate in opened surgeries (5 % of misplaced pedicle screws vs 17 % in Group C) (p = 0.025). For one vertebra, the average surgical running time reached 8 min in Group C vs 21 min in Group N for percutaneous surgeries (p = 3.42 x 10(-9)), 7.33 min in Group C vs 16.33 min in Group N (p = 2.88 x 10(-7)) for opened surgeries. The 3D navigation device delivered less radiation in percutaneous procedures [0.6 vs 1.62 mSv in Group C (p = 2.45 x 10(-9))]. For opened surgeries, it was twice higher in Group N with 0.21 vs 0.1 mSv in Group C (p = 0.022). The rate of misplaced pedicle screws with conventional techniques was nearly the same as most papers and a little bit higher with CAS. Surgical running time and radiation exposure were consistent with many studies. Our work hypothesis is partially confirmed, depending on the type of surgery (opened or closed procedure).
引用
收藏
页码:1738 / 1744
页数:7
相关论文
共 50 条
  • [21] Towards intra-operative 3D nuclear imaging: Reconstruction of 3D radioactive distributions using tracked gamma probes
    Wendler, Thomas
    Hartl, Alexander
    Lasser, Tobias
    Traub, Joerg
    Daghighian, Farhad
    Ziegler, Sibylle I.
    Navab, Nassir
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION- MICCAI 2007, PT 2, PROCEEDINGS, 2007, 4792 : 909 - +
  • [22] Effects of intra-operative magnesium sulfate infusion on orthognathic surgery: A prospective and randomized controlled trial
    Hua, Xiaoxiao
    Chen, Yanling
    Wu, Zhi
    Zheng, Guangsen
    Yang, Dongye
    Li, Jing
    Wu, Qiaomei
    Fan, Wenguo
    HELIYON, 2024, 10 (09)
  • [23] Vascular image registration for intra-operative 3D ultrasound annotation
    Jomier, J
    Weeks, S
    Aylward, SR
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1308 - 1308
  • [24] Intra-Operative 3D Pose Estimation of Fractured Bone Segments for Image Guided Orthopedic Surgery
    Gamage, P.
    Xie, S. Q.
    Delmas, P.
    Xu, P.
    Mukherjee, S.
    2008 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS, VOLS 1-4, 2009, : 288 - +
  • [25] Intra-operative imaging for spinal level localisation in lumbar surgery
    Dablouk, Mohamed O.
    Sajjad, Jahangir
    Lim, Chris
    Kaar, George
    O'Sullivan, Michael G. J.
    BRITISH JOURNAL OF NEUROSURGERY, 2019, 33 (03) : 352 - 356
  • [26] Intra-operative imaging facilitates minimally invasive parathyroid surgery
    McGreal, G
    Evoy, D
    Neary, P
    Cahill, R
    Winters, D
    Ryan, M
    O'Sullivan, G
    Redmond, HP
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (04): : S89 - S89
  • [27] Intra-operative visualisation of 3D temperature maps and 3D navigation during tissue cryoablation
    Samset, E
    Mala, T
    Aurdal, L
    Balasingham, I
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2005, 29 (06) : 499 - 505
  • [28] Intra-operative Imaging for Spinal Level Localisation in Lumbar Surgery
    Dablouk, Mohamed
    Sajjad, Jahangir
    Kaar, George
    Lim, Chris
    O'Sullivan, Michael
    IRISH JOURNAL OF MEDICAL SCIENCE, 2018, 187 : 320 - 321
  • [29] Dose comparative study between two different 3D mobile intra-operative systems
    Sans Merce, M.
    Pitteloud, N.
    Savoye, F.
    RADIOPROTECTION, 2020, 55 (03) : 179 - 185
  • [30] Integration of intra-operative 3D ultrasound with pre-operative MRI for neurosurgical guidance
    Gobbi, DG
    Comeau, RM
    Lee, BKH
    Peters, TM
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 1738 - 1740