Diagnostic methods in revealing internal moisture in polymer housed metal oxide surge arresters

被引:14
|
作者
Lahti, K [1 ]
Kannus, K [1 ]
Nousiainen, K [1 ]
机构
[1] Tampere Univ Technol, Inst Power Engn, FIN-33101 Tampere, Finland
关键词
arresters; degradation; insulation; leak detection; moisture; partial discharges; polymers;
D O I
10.1109/TPWRD.2002.803694
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Diagnostic measurements performed for surge arresters are normally studied by evaluating their suitability to detect aging and degradation of metal oxide material. The suitability of different methods for revealing internal moisture in arresters has not been studied much. This aspect is considered in the paper based on measurement results obtained during a 1.5-yr laboratory test series conducted for six different types of polymer-housed distribution class arresters. AC power losses, third-harmonic content of resistive leakage current, dc leakage current, and partial discharge measurement results over the test period are given and discussed. Details of the measurement procedures suitable for measuring polymeric arresters with internal moisture are also studied. AC power loss and dc leakage current measurements were found to be good methods, whereas the other two can only be used as additional methods when diagnosing internal moisture in polymer-housed arresters.
引用
收藏
页码:951 / 956
页数:6
相关论文
共 50 条
  • [31] Evaluation of the insulation design of polymer housed surge arresters using salt-fog test
    Biglar, B
    Jayaram, S
    Cherney, EA
    2000 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS. I & II, 2000, : 385 - 388
  • [32] Multistress accelerated aging of polymer housed surge arresters under simulated coastal Florida conditions
    Sundararajan, R
    Soundarajan, E
    Mohammed, A
    Graves, J
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2006, 13 (01) : 211 - 226
  • [33] Artificial pollution tests on porcelain-housed metal-oxide surge arresters for 275kV power systems
    Kado, H
    Izumi, K
    Shirakawa, S
    Komatsu, K
    Watanabe, H
    Yamaguchi, M
    Nakajima, M
    Kobayashi, M
    Nishimura, S
    2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 2087 - 2092
  • [34] Investigation of heat-of-fusion heat sinks for polymer-type metal oxide surge arresters
    Zheng, Zhong
    Imai, Toshiya
    Sakaguchi, Sumiko
    Kasuga, Yasunori
    Boggs, Steven
    CONFERENCE RECORD OF THE 2006 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2006, : 253 - +
  • [35] Virginia power's use of polymer housed surge arresters to protect 138 kV transmission lines
    Babik, JJ
    Lamb, ML
    1996 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE PROCEEDINGS, 1996, : 283 - 287
  • [36] SURGE ARRESTERS WITH METAL-OXIDE RESISTORS FOR OPTIMUM OVERVOLTAGE PROTECTION
    MAYER, A
    RUDOLPH, R
    BROWN BOVERI REVIEW, 1985, 72 (12): : 576 - 585
  • [37] ANALYTICAL METHOD FOR PERFORMANCE PREDICTION OF METAL-OXIDE SURGE ARRESTERS
    LAT, MV
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (10): : 2665 - 2674
  • [38] Comments on metal oxide surge arresters surges energy absorption capacity
    Martinez, MLB
    Zanetta, LC
    CONFERENCE RECORD OF THE 1996 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1996, : 498 - 501
  • [39] Technical tend on evaluation and application of metal-oxide surge arresters
    Kado, Hiroyuki
    Tsuge, Kenji
    Saito, Hiroki
    Miyagi, Tsukasa
    IEEJ Transactions on Power and Energy, 2018, 138 (01) : 1 - 4
  • [40] A Bibliometric and Comprehensive Review on Condition Monitoring of Metal Oxide Surge Arresters
    Zacarias, Tiago Goncalves
    Sant'Ana, Wilson Cesar
    SENSORS, 2024, 24 (01)