Quantitative analysis of the electrode polarization and pH measurement

被引:0
|
作者
Bau, JG [1 ]
Wang, WK [1 ]
Wang, YYL [1 ]
机构
[1] Natl Taiwan Univ, Dept Phys, Taipei, Taiwan
关键词
polarization; electrode; pH; stainless steel; Ringer solution;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A quantitative analysis of the electrode polarization is proposed as a method of detection. The transient current of the step potential was used, and demonstrated on the pH measurement. By using a stainless steel electrode, we can clearly distinguish pH 7 from pH 5.9 in the Ringer solutions, while there is 9 times S.E. in between on the K-TQ plots. TQ is the average current from 0 to 2.5 msec, and K is the transient conductance. It is also found the contribution to the transient current of pH is 100 times larger than that of K+ and Cl- ions. With the advantages of a minimized electrode and short response time, our method will be practical for either in vitro or in vivo tests.
引用
收藏
页码:139 / 145
页数:7
相关论文
共 50 条
  • [41] PH AND BLOOD - GAS ANALYSIS - METHODS OF MEASUREMENT AND SOURCES OF ERROR USING ELECTRODE SYSTEMS .I.
    ADAMS, AP
    MORGANHU.JO
    SYKES, MK
    ANAESTHESIA, 1967, 22 (04) : 575 - &
  • [42] Quantitative analysis for the measurement of angiogenesis
    Mazo, J
    Blebea, J
    Kihara, T
    McGlaughlin, P
    Anderson, K
    Atnip, R
    Zagon, I
    FASEB JOURNAL, 1999, 13 (04): : A527 - A527
  • [44] EFFECT OF ELECTRODE POLARIZATION DURING MEASUREMENT OF DIELECTRIC LOSSES IN BIOLOGICAL SPECIMENS
    FILANOVS.TP
    IOFFE, GA
    BIOPHYSICS-USSR, 1967, 12 (06): : 1281 - &
  • [45] EFFECT OF ELECTRODE POLARIZATION OF THE MEASUREMENT ERROR OF THE DIELECTRIC-CONSTANT OF LIQUIDS
    BYKOVA, ZY
    KLUGMAN, IY
    SORKIN, YI
    MEASUREMENT TECHNIQUES, 1980, 23 (10) : 936 - 938
  • [46] EFFECT OF ELECTRODE POLARIZATION ON MEASUREMENT OF DIELECTRIC-CONSTANT OF CONDUCTIVE SUBSTANCES
    GANGNUS, VS
    SUS, AN
    BEREZIN, VV
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII FIZIKA, 1975, (08): : 39 - 43
  • [47] MEASUREMENT OF JEJUNAL SURFACE PH INSITU BY PLASTIC PH ELECTRODE IN PATIENTS WITH CELIAC-DISEASE
    RAWLINGS, JM
    LUCAS, ML
    RUSSELL, RI
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1987, 22 (03) : 377 - 384
  • [48] INTRAMURAL PH - A QUANTITATIVE MEASUREMENT FOR PREDICTING COLORECTAL ANASTOMOTIC HEALING
    SENAGORE, A
    MILSOM, JW
    WALSHAW, RK
    DUNSTAN, R
    MAZIER, WP
    CHAUDRY, IH
    DISEASES OF THE COLON & RECTUM, 1990, 33 (03) : 175 - 179
  • [49] MEASUREMENT OF PH OF A CATHODIC LAYER IN POLYLIGAND SYSTEMS BY CATHODIC AND ANODIC POLARIZATION
    OREKHOVA, VV
    ANDRYUSHCHENKO, FK
    SAKHNENKO, ND
    UKRAINSKII KHIMICHESKII ZHURNAL, 1983, 49 (05): : 518 - 520
  • [50] QUANTITATIVE ANALYSIS OF THE POLARIZATION CHARACTERISTICS OF ATHEROSCLEROTIC PLAQUES
    Gubarkova, Ekaterina V.
    Kirillin, Mikhail Yu.
    Dudenkova, Varvara V.
    Kiseleva, Elena B.
    Moiseev, Alexander A.
    Gelikonov, Grigory V.
    Timofeeva, Lidia B.
    Fiks, Ilya I.
    Feldchtein, Felix I.
    Gladkova, Natalia D.
    BIOPHOTONICS: PHOTONIC SOLUTIONS FOR BETTER HEALTH CARE V, 2016, 9887