Glycated albumin in diabetes mellitus: a meta-analysis of diagnostic test accuracy

被引:8
|
作者
Chume, Fernando C. [1 ,2 ,5 ]
Freitas, Priscila A. C. [2 ,6 ]
Schiavenin, Luisa G. [2 ]
Pimentel, Ana L. [2 ,7 ]
Camargo, Joiza Lins [1 ,2 ,3 ,4 ]
机构
[1] Univ Fed Rio Grande do Sul, Grad Program Med Sci Endocrinol, BR-90035003 Porto Alegre, RS, Brazil
[2] Hosp Clin Porto Alegre, Ctr Pesquisa Clin, Diabet & Metab Grp, Porto Alegre, RS, Brazil
[3] Hosp Clin Porto Alegre, Endocrinol Div, Rua Ramiro Barcellos 2350,1 Andar, BR-90003500 Porto Alegre, RS, Brazil
[4] Hosp Clin Porto Alegre, Expt Res Ctr, Rua Ramiro Barcellos 2350,1 Andar, BR-90003500 Porto Alegre, RS, Brazil
[5] Univ Zambeze, Fac Hlth Sci, Beira, Mozambique
[6] Hosp Clin Porto Alegre HCPA, Clin Biochem Unit, Lab Diag Div, Porto Alegre, RS, Brazil
[7] Nuvisan Pharma Serv, Porto Alegre, RS, Brazil
关键词
diabetes mellitus; diagnosis; diagnostic accuracy; glycated albumin; meta-analysis; FASTING PLASMA-GLUCOSE; CARDIOVASCULAR OUTCOMES; RISK; POPULATION; PREVALENCE; TOLERANCE; MORTALITY; HYPERGLYCEMIA; FRUCTOSAMINE; BIOMARKER;
D O I
10.1515/cclm-2022-0105
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives Guidelines recommend the diagnosis of diabetes should be based on either plasma glucose or glycated hemoglobin (HbA(1C)) findings. However, lately studies have advocated glycated albumin (GA) as a useful alternative to HbA(1c). We conducted a systematic review and meta-analysis to determine the overall diagnostic accuracy of GA for the diagnosis of diabetes. Content We searched for articles of GA diabetes diagnostic accuracy that were published up to August 2021. Studies were selected if reported an oral glucose tolerance test as a reference test, measured GA levels by enzymatic methods, and had data necessary for 2 x 2 contingency tables. A bivariate model was used to calculate the pooled estimates. This meta-analysis included nine studies, totaling 10,007 individuals. Of those, 3,106 had diabetes. The studies showed substantial heterogeneity caused by a non-threshold effect and reported different GA optimal cut-offs for diagnosing diabetes. The pooled diagnostic odds ratio (DOR) was 15.93 and the area under the curve (AUC) was 0.844, indicating a good level of overall accuracy for the diagnosis of diabetes. The effect of the GA threshold on diagnostic accuracy was reported at 15.0% and 17.1%. The optimal cut-off for diagnosing diabetes with GA was estimated as 17.1% with a pooled sensitivity of 55.1% (95% CI 36.7%-72.2%) and specificity of 94.4% (95% CI 85.3%-97.9%). Outlook GA has good diabetes diagnostic accuracy. A GA threshold of 17.1% may be considered optimal for diagnosing diabetes in previously undiagnosed individuals.
引用
收藏
页码:961 / 974
页数:14
相关论文
共 50 条
  • [21] Lucica® GA-L Glycated Albumin Assay Kit A New Diagnostic Test for Diabetes Mellitus
    Kohzuma, Takuji
    Koga, Masafumi
    MOLECULAR DIAGNOSIS & THERAPY, 2010, 14 (01) : 49 - 51
  • [22] Diagnostic value of glycated haemoglobin as a screening test for diabetes mellitus
    Hu, Y.
    Liu, W.
    Chen, Y.
    Zhang, M.
    Li, S.
    Liu, X.
    Han, T.
    Ji, L.
    DIABETOLOGIA, 2009, 52 : S122 - S122
  • [23] The usefulness of glycated albumin for post-transplantation diabetes mellitus after kidney transplantation: A diagnostic accuracy study
    Laura Pimentel, Ana
    Kieling Hernandez, Mayana
    Correa Freitas, Priscila Aparecida
    Chimela Chume, Fernando
    Lins Camargo, Joiza
    CLINICA CHIMICA ACTA, 2020, 510 : 330 - 336
  • [24] Meta-analysis of diagnostic test accuracy in neurosurgical practice
    Dubourg, Julie
    Berhouma, Moncef
    Cotton, Michael
    Messerer, Mahmoud
    NEUROSURGICAL FOCUS, 2012, 33 (01)
  • [25] The oral glucose tolerance test for the diagnosis of diabetes mellitus in patients during acute coronary syndrome hospitalization: a meta-analysis of diagnostic test accuracy
    Yicong Ye
    Hongzhi Xie
    Xiliang Zhao
    Shuyang Zhang
    Cardiovascular Diabetology, 11
  • [26] The oral glucose tolerance test for the diagnosis of diabetes mellitus in patients during acute coronary syndrome hospitalization: a meta-analysis of diagnostic test accuracy
    Ye, Yicong
    Xie, Hongzhi
    Zhao, Xiliang
    Zhang, Shuyang
    CARDIOVASCULAR DIABETOLOGY, 2012, 11
  • [27] Diagnostic Utility of Serum Glycated Albumin for Diabetes Mellitus and Its Correlation With Hyperlipidemia
    Park, Sholhui
    Lee, Wookeun
    Chung, Hae-Sun
    Hong, Ki-Sook
    ANNALS OF LABORATORY MEDICINE, 2016, 36 (04) : 306 - 312
  • [28] A diagnostic test accuracy meta-analysis of maternal serum ischemia-modified albumin for detection of preeclampsia
    Reddy, Varikasuvu Seshadri
    Munikumar, Manne
    Duggina, Pragathi
    Varma, Neelakant
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2019, 32 (13): : 2173 - 2181
  • [29] Diagnostic test accuracy: methods for systematic review and meta-analysis
    Campbell, Jared M.
    Klugar, Miloslav
    Ding, Sandrine
    Carmody, Dennis P.
    Hakonsen, Sasja J.
    Jadotte, Yuri T.
    White, Sarahlouise
    Munn, Zachary
    INTERNATIONAL JOURNAL OF EVIDENCE-BASED HEALTHCARE, 2015, 13 (03) : 154 - 162
  • [30] Improved confidence regions in meta-analysis of diagnostic test accuracy
    Ito, Tsubasa
    Sugasawa, Shonosuke
    COMPUTATIONAL STATISTICS & DATA ANALYSIS, 2021, 153