A Comparison of Three Different Attachment Systems for Mandibular Two-Implant Overdentures: One-Year Report

被引:143
|
作者
Kleis, Wilfried K. [1 ]
Kaemmerer, Peer W. [1 ]
Hartmann, Sinsa [2 ]
Al-Nawas, Bilal [1 ]
Wagner, Wilfried [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Dept Oral & Maxillofacial Surg, D-55131 Mainz, Germany
[2] Johannes Gutenberg Univ Mainz, Dept Prosthet Dent, D-55131 Mainz, Germany
关键词
abutment; attachment system; dental implant; edentulous mandible; locator; prospective; randomized; self-aligning attachment system; traditional ball attachment; RANDOMIZED CLINICAL-TRIAL; HEALTH IMPACT PROFILE; IMPLANT-RETAINED OVERDENTURES; PATIENT SATISFACTION; PSYCHOMETRIC PROPERTIES; COMPLETE DENTURES; BAR ATTACHMENTS; BALL; VERSION; TRANSLATION;
D O I
10.1111/j.1708-8208.2009.00154.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: There is a lack of clinical studies on the self-aligning attachment system (Locator (R); Zest Anchors, Inc. homepage, Escondido, CA, USA) for two-implant-retained overdentures in the edentulous mandible. Therefore, a comparison of the Locator with two traditional designs (a rotational gold matrix and a rubber O-ring type) in clinical 1-year use was conducted. Materials and Methods: From 2003 to 2007, 60 patients received two Osseotite (R) TG Standard implants (BIOMET 3i Implant Innovations, Palm Beach Gardens, FL, USA) in the intraforaminal area of the edentulous mandible. The implants were left unloaded for 3.5 months, randomized to three different attachment systems, and loaded through a mandibular overdenture. Twenty-three patients received a self-aligning attachment system (Locator) and 33 patients a ball attachment (Dal-Ro (R) [BIOMET 3i Implant Innovations] n = 25; TG-O-Ring (R) [Cendres & Metaux SA, Biel-Bienne, Switzerland] n = 8). After 12 months of delivery of the overdentures, the oral situation was evaluated: prosthodontic maintenance and biologic complications, subjective patients' experience, and oral health-related life quality (Oral Health Impact Profile [OHIP-G 49]). Results: After 1-year of clinical service, 8 of 120 implants were lost (9.6%). The Locator system brought up 34 prosthetic complications, especially the need for change of the male parts or activation because of loss of retention. The TG-O-Ring patients showed 14 complications, most of them the change of the O-Rings. The patients with the Dal-Ro abutment had seven minor complications in 12 months of clinical use. Biologic complications and patients' oral health-related life quality showed no significant difference among the three experimental groups. Conclusions: Prosthodontic maintenance was restricted to loss of retention for all systems. Within the observation period of this study, the self-aligning attachment system showed a higher rate of maintenance than the ball attachments. The patients' oral health-related life qualities as well as the biologic parameters do not differ when using the three abutment systems.
引用
收藏
页码:209 / 218
页数:10
相关论文
共 50 条
  • [41] Does a prosthodontist spend more time providing mandibular two-implant overdentures than conventional dentures?
    Takanashi, Y
    Penrod, JR
    Chehade, A
    Klemetti, E
    Savard, A
    Lund, JP
    Feine, JS
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2002, 15 (04) : 397 - 403
  • [42] Attachment Systems for Mandibular Single-Implant Overdentures: An In Vitro Retention Force Investigation on Different Designs
    Alsabeeha, Nabeel
    Atieh, Momen
    Swain, Michael V.
    Payne, Alan G. T.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2010, 23 (02) : 160 - 166
  • [43] A clinical comparison of prosthetic complications of implant-supported overdentures with different attachment systems
    Karabuda, Cuneyt
    Yaltink, Mehmet
    Bayraktar, Mehmet
    IMPLANT DENTISTRY, 2008, 17 (01) : 74 - 81
  • [44] A prospective study of immediately loaded single implant-retained mandibular overdentures: Preliminary one-year results
    Liddelow, Glen J.
    Henry, Patrick J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2007, 97 (06): : S126 - S137
  • [45] A Prospective Study of Early Loaded Single Implant-Retained Mandibular Overdentures: Preliminary One-Year Results
    El-Sheikh, Ali M.
    Shihabuddin, Omar F.
    Ghoraba, Sahar M. F.
    INTERNATIONAL JOURNAL OF DENTISTRY, 2012, 2012
  • [46] Impact of mandibular two-implant retained overdentures on life quality in a group of elderly Turkish edentulous patients
    Geckili, Onur
    Bilhan, Hakan
    Bilgin, Tayfun
    ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2011, 53 (02) : 233 - 236
  • [47] Is oral health-related quality of life stable following rehabilitation with mandibular two-implant overdentures?
    Jabbour, Z.
    Emami, E.
    de Grandmont, P.
    Rompre, P. H.
    Feine, J. S.
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (10) : 1205 - 1209
  • [48] One-year prosthetic outcomes with implant overdentures: A randomized clinical trial
    Walton, JN
    MacEntee, MI
    Glick, N
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2002, 17 (03) : 391 - 398
  • [49] A cost comparison of mandibular two-implant overdenture and conventional denture treatment
    Takanashi, Y
    Penrod, JR
    Lund, JP
    Feine, JS
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2004, 17 (02) : 181 - 186
  • [50] A one-year follow-up analysis of the efficacy of implant overdentures
    Awad, MA
    Lund, JP
    Dufresne, E
    Feine, JS
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 150 - 150