Calibrating Blood Glucose Monitoring Systems

被引:0
|
作者
Andreis, E. [1 ]
Appel, M. [1 ]
Kuellmer, K. [1 ]
机构
[1] Roche Diagnost, Mannheim, Germany
来源
DIABETES STOFFWECHSEL UND HERZ | 2013年 / 22卷 / 03期
关键词
blood glucose measurement; accuracy; trueness; reference method; traceability; DILUTION MASS-SPECTROMETRY; WHOLE-BLOOD; ACCURATE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Blood glucose monitoring systems should give results close to "real blood glucose" values for reliable measurement, so manufacturers of such systems are required to implement an effective reference method for glucose measurement. Methods: The highest-order method of measuring blood glucose, isotope dilution gas chromatography/mass spectrometry (ID/GC/MS), combines gas chromatography (GC) and mass spectroscopy, and is calibrated and controlled using certified primary reference materials from the National Institute of Standards and Technology in the US. Time-consuming sample preparation keeps ID/GC/MS from routine use, so the hexokinase method is used instead with direct alignment to the reference method using a three-stage calibration hierarchy to establish traceability between the hexokinase method and ID/GC/MS. Results: The ID/GC/MS method currently provides the most accurate results the uncertainty value of the whole analytical procedure accumulates to +/- 1.7% (95% confidence interval). More than 95% of all control measurements lie within the 1.7% range. Conclusions: Reliable glucose measurement requires an unbroken traceability chain from reference material to measurement results obtained by blood glucose monitoring systems; laboratory methods that do not allow glucose measurement traceability should be abandoned.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 50 条
  • [1] Accuracy of self monitoring blood glucose systems in different ranges of blood glucose
    Kulozik, F.
    Platten, I.
    Hasslacher, C.
    DIABETOLOGIA, 2012, 55 : S426 - S426
  • [2] Blood Glucose Monitoring Systems with Voice Guidance
    Jendrike, N.
    Liebing, C.
    Drossel, D.
    Baumstark, A.
    Pleus, S.
    Haug, C.
    Freckmann, G.
    DIABETES STOFFWECHSEL UND HERZ, 2019, 28 (05): : 253 - 259
  • [3] INTRAVASCULAR BLOOD GLUCOSE MONITORING SYSTEMS FOR THE OR, SICU, AND MICU
    Joseph, J. I.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A11 - A11
  • [4] EVALUATION OF HOME BLOOD-GLUCOSE MONITORING SYSTEMS
    VLAHOS, WD
    YALE, JF
    CLINICAL AND INVESTIGATIVE MEDICINE-MEDECINE CLINIQUE ET EXPERIMENTALE, 1987, 10 (04): : B68 - B68
  • [5] Simulating Multisensor Noninvasive Blood Glucose Monitoring Systems
    Asaduzzaman, Abu
    Samadarsinee, Soumyashree
    Chidella, Kishore K.
    SOUTHEASTCON 2016, 2016,
  • [6] EVALUATION OF SYSTEMS FOR HOME BLOOD-GLUCOSE MONITORING
    ANTONELLA, MA
    FABIETTI, PG
    MASSIBENEDETTI, M
    DIABETOLOGIA, 1982, 23 (03) : 291 - 291
  • [7] PERFORMANCE EVALUATION OF FOUR BLOOD GLUCOSE MONITORING SYSTEMS
    Link, M.
    Freckmann, G.
    Baumstark, A.
    Schmid, C.
    Pleus, S.
    Haug, C.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A74 - A74
  • [8] Effects of applying insufficient blood on three blood glucose monitoring systems
    Shalapay, CE
    Cembrowski, GS
    CLINICAL CHEMISTRY, 2004, 50 (06) : A169 - A169
  • [9] BLOOD GLUCOSE MONITORING SYSTEMS' PERFORMANCE IN LOW BLOOD GLUCOSE RANGE AND ITS CLINICAL IMPLICATIONS
    Shaginian, R.
    Richardson, J.
    Pardo, S.
    Stuhr, A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A142 - A142
  • [10] Measurement Performance of Two Continuous Tissue Glucose Monitoring Systems Intended for Replacement of Blood Glucose Monitoring
    Freckmann, Guido
    Link, Manuela
    Pleus, Stefan
    Westhoff, Antje
    Kamecke, Ulrike
    Haug, Cornelia
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 (08) : 541 - 549