Simulating Multisensor Noninvasive Blood Glucose Monitoring Systems

被引:0
|
作者
Asaduzzaman, Abu [1 ]
Samadarsinee, Soumyashree [1 ]
Chidella, Kishore K. [1 ]
机构
[1] Wichita State Univ, Dept Elect Engn & Comp Sci, Wichita, KS 67260 USA
来源
关键词
blood glucose monitoring; noninvasive; IR sensors; ultrasonic; MEMS; piezoelectric; regression analysis;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Diabetes and related complications are responsible for early death - one person in every 7 seconds. Long term and short term complications due to diabetes can be reduced through proper diet, physical exercise, and medication. In order to assess the pattern of glucose changes of diabetic patients (for determining the appropriate drugs), concentration of glucose in blood needs to be monitored. The pain and inconvenience (due to pricking fingers) in the current invasive blood glucose monitoring technique has led to the emergence of noninvasive blood glucose monitoring (NIBGM) techniques. In this paper, we propose a multisensor NIBGM system using infrared (IR) sensor and ultrasonic micro-electro-micro mechanical (MEMS) technology. We simulate the proposed NIBGM system using COMSOL Multiphysics software and calibrate the system using Matlab code. Lead free piezoelectric materials are evaluated for ultrasonic sensors. Behavior of ultrasonic MEMS is simulated by varying the concentration of blood glucose. The simulation results are cross validated with actual glucose concentration to assess errors. According to simulation results and Clarke error grid analysis (EGA), the proposed NIBGM system has potential to enhance accuracy. By adding easiness and comfort (due to no pricking), the proposed multisensor NIBGM device should provide better assistance to monitor and manage diabetes.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Methods for Noninvasive Determination of Blood Glucose Concentration Using Multisensor Systems
    Mikhailov M.O.
    Pozhar K.V.
    [J]. Biomedical Engineering, 2023, 57 (02) : 121 - 126
  • [2] Noninvasive blood glucose monitoring
    Klonoff, DC
    [J]. DIABETES CARE, 1997, 20 (03) : 433 - 437
  • [3] Regularised Model Identification Improves Accuracy of Multisensor Systems for Noninvasive Continuous Glucose Monitoring in Diabetes Management
    Zanon, Mattia
    Sparacino, Giovanni
    Facchinetti, Andrea
    Talary, Mark S.
    Caduff, Andreas
    Cobelli, Claudio
    [J]. JOURNAL OF APPLIED MATHEMATICS, 2013,
  • [4] Investigations on Multisensor-Based Noninvasive Blood Glucose Measurement System
    Yadav, Jyoti
    Rani, Asha
    Singh, Vijander
    Murari, Bhaskar Mohan
    [J]. JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2017, 11 (03):
  • [5] Noninvasive Method for Blood Glucose Measuring and Monitoring
    Pavlovich, Loshitskiy Pavel
    Mynziak, Dmitriy Yurievich
    [J]. 2013 IEEE XXXIII INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2013, : 255 - 257
  • [6] Optical Methods for Noninvasive Blood Glucose Monitoring
    N. A. Bazaev
    Yu. P. Masloboev
    S. V. Selishchev
    [J]. Biomedical Engineering, 2012, 45 (6) : 229 - 233
  • [7] Noninvasive Monitoring of Blood Glucose with Raman Spectroscopy
    Pandey, Rishikesh
    Paidi, Santosh Kumar
    Valdez, Tulio A.
    Zhang, Chi
    Spegazzini, Nicolas
    Dasari, Ramachandra Rao
    Barman, Ishan
    [J]. ACCOUNTS OF CHEMICAL RESEARCH, 2017, 50 (02) : 264 - 272
  • [8] IoT Architectures for Noninvasive Blood Glucose and Blood Pressure Monitoring
    Guntha, Ramesh
    [J]. PROCEEDINGS OF THE 2019 9TH INTERNATIONAL SYMPOSIUM ON EMBEDDED COMPUTING AND SYSTEM DESIGN (ISED 2019), 2019, : 120 - 124
  • [9] Dermis-simulating phantom for noninvasive blood glucose sensing with OCT
    Yang, Guoqing
    Yao, X. Steve
    Su, Ya
    Liu, Suling
    Feng, Ting
    Chen, Lei
    Wang, Hongjie
    Li, Wenping
    [J]. 2018 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2018,
  • [10] Noninvasive blood glucose monitoring in the terahertz frequency range
    Cherkasova, Olga
    Nazarov, Maxim
    Shkurinov, Alexander
    [J]. OPTICAL AND QUANTUM ELECTRONICS, 2016, 48 (03)