Calibrating Blood Glucose Monitoring Systems

被引:0
|
作者
Andreis, E. [1 ]
Appel, M. [1 ]
Kuellmer, K. [1 ]
机构
[1] Roche Diagnost, Mannheim, Germany
来源
DIABETES STOFFWECHSEL UND HERZ | 2013年 / 22卷 / 03期
关键词
blood glucose measurement; accuracy; trueness; reference method; traceability; DILUTION MASS-SPECTROMETRY; WHOLE-BLOOD; ACCURATE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Blood glucose monitoring systems should give results close to "real blood glucose" values for reliable measurement, so manufacturers of such systems are required to implement an effective reference method for glucose measurement. Methods: The highest-order method of measuring blood glucose, isotope dilution gas chromatography/mass spectrometry (ID/GC/MS), combines gas chromatography (GC) and mass spectroscopy, and is calibrated and controlled using certified primary reference materials from the National Institute of Standards and Technology in the US. Time-consuming sample preparation keeps ID/GC/MS from routine use, so the hexokinase method is used instead with direct alignment to the reference method using a three-stage calibration hierarchy to establish traceability between the hexokinase method and ID/GC/MS. Results: The ID/GC/MS method currently provides the most accurate results the uncertainty value of the whole analytical procedure accumulates to +/- 1.7% (95% confidence interval). More than 95% of all control measurements lie within the 1.7% range. Conclusions: Reliable glucose measurement requires an unbroken traceability chain from reference material to measurement results obtained by blood glucose monitoring systems; laboratory methods that do not allow glucose measurement traceability should be abandoned.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 50 条
  • [31] Accuracy Performance of Six Self-Monitoring Blood Glucose Systems
    Kum, Maxwell C.
    Manesh, Kalayil Manian
    Wang, Steven Chialin
    Bailey, Timothy S.
    DIABETES, 2015, 64 : A238 - A239
  • [32] Comparative Accuracy Evaluation of Six Blood Glucose Monitoring Systems (BGMSs)
    Klaff, Leslie J.
    Brazg, Ronald L.
    Hughes, Kristen
    Tideman, Ann M.
    Schachner, Holly C.
    Stenger, Patricia
    Pardo, Scott
    Dunne, Nancy
    Parkes, Joan Lee
    DIABETES, 2013, 62 : A221 - A221
  • [33] Nonadjunctive Use of Tissue Glucose Monitoring Systems: Differences in Measured Tissue and Blood Glucose Concentrations
    Freckmann, Guido
    Link, Manuela
    Pleus, Stefan
    Kamecke, Ulrike
    Westhoff, Antje
    Haug, Cornelia
    DIABETES, 2017, 66 : A236 - A237
  • [34] Blood glucose self monitoring
    Wascher, Thomas C.
    Stechemesser, Lars
    Harreiter, Jurgen
    WIENER KLINISCHE WOCHENSCHRIFT, 2023, 135 (SUPPL 1) : 143 - 146
  • [35] MONITORING BLOOD-GLUCOSE
    KNIGHT, AH
    BRITISH MEDICAL JOURNAL, 1980, 280 (6209): : 253 - 253
  • [36] Home blood glucose monitoring
    Foster, SA
    Goode, JVKR
    Small, RE
    ANNALS OF PHARMACOTHERAPY, 1999, 33 (03) : 355 - 363
  • [37] CONTINUOUS MONITORING OF BLOOD GLUCOSE
    ROSEVEAR, JW
    CLINICAL CHEMISTRY, 1971, 17 (07) : 628 - &
  • [38] Monitoring blood glucose levels
    Lecklider, Tom
    EE: Evaluation Engineering, 2015, 54 (08): : 22 - 23
  • [39] Continuous monitoring of blood glucose
    Robert, JJ
    HORMONE RESEARCH, 2002, 57 : 81 - 84
  • [40] DYNAMIC MONITORING OF BLOOD GLUCOSE
    KADISH, AH
    DIABETES, 1967, 16 (07) : 528 - &