The most efficient position of shading devices in a double-skin facade

被引:124
|
作者
Gratia, Elisabeth [1 ]
De Herde, Andre [1 ]
机构
[1] Univ Catholique Louvain, B-1348 Louvain, Belgium
关键词
double-skin facade; thermal modelling; office building; shading devices; cooling strategies;
D O I
10.1016/j.enbuild.2006.09.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent years, there has been a great deal of interest in double-skin facades due to the advantages claimed for this technology in terms of energy saving in the cold season, protection from external noise and wind loads and their high-tech image. The advent of computers and other office equipment has increased the internal heat gains in most offices. Highly glazed facades, together with the extra heat gains from the electric lighting made necessary by deep floor plans and the wider use of false ceilings, have increased the risk of overheating. To preserve comfort and reduce cooling loads, it is important to apply natural cooling strategies, including solar protections use. External solar protections are more effective than internal shading devices. In the case of the double-skin facade, the blinds can be integrated in the cavity. It is thus protected from the bad weather and pollution. Solar protection can remain in place even in the event of important wind, which represents an undeniable advantage for the buildings with great height. This article examines the influence of the position and the colour of the blinds on the cooling consumption of an office building with a double-skin facade. (C) 2006 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:364 / 373
页数:10
相关论文
共 50 条
  • [1] Greenhouse effect in double-skin facade
    Gratia, Elisabeth
    De Herde, Andre
    ENERGY AND BUILDINGS, 2007, 39 (02) : 199 - 211
  • [2] Natural ventilation in a double-skin facade
    Gratia, E
    De Herde, A
    ENERGY AND BUILDINGS, 2004, 36 (02) : 137 - 146
  • [3] Double-skin facade in Flotran CFD
    Palko, Milan
    ADVANCED BUILDING CONSTRUCTION AND MATERIALS 2013, 2014, 855 : 154 - 159
  • [4] Effect of annual solar radiation on simple facade, double-skin facade and double-skin facade filled with phase change materials for saving energy
    Alqaed, Saeed
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 51
  • [5] Optimal operation of a south double-skin facade
    Gratia, E
    De Herde, A
    ENERGY AND BUILDINGS, 2004, 36 (01) : 41 - 60
  • [6] Chimney effect assessment of the double-skin facade
    Qiu, Zhong-Zhu
    Li, Peng
    Chow, Tin-Tai
    Ren, Jian-Xing
    Wang, Wen-Huan
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2009, 36 (SUPPL.): : 146 - 150
  • [7] A qualitative investigation on double-skin facade fires
    Chow, C. L.
    1ST INTERNATIONAL SEMINAR FOR FIRE SAFETY OF FACADES, 2013, 9
  • [8] Chimney Effect Assessment of the Double-skin Facade
    QIU ZhongzhuLI PengCHOW TintaiREN JianxingWANG WenhuanSchool of Energy Environment EngineeringShanghai University of Electric PowerShanghai ChinaSchool of Mechanical EngineeringTongji UniversityShanghai ChinaDivision of Building Science TechnologyCity University of Hong KongHong Kong SARChina
    湖南大学学报(自然科学版), 2009, 36(S1) (自然科学版) : 146 - 150
  • [9] Chimney Effect Assessment of the Double-skin Facade
    QIU Zhong-zhu1
    2.School of Mechanical Engineering
    3.Division of Building Science & Technology
    湖南大学学报(自然科学版), 2009, (S1) : 146 - 150
  • [10] Comparative Analysis of the Daylight and Building-Energy Performance of a Double-Skin Facade System with Multisectional Shading Devices of Different Control Strategies
    Hong, Xiaoqiang
    Lin, Junwei
    Yang, Xuan
    Wang, Shaosen
    Shi, Feng
    JOURNAL OF ENERGY ENGINEERING, 2022, 148 (03)