The most efficient position of shading devices in a double-skin facade

被引:124
|
作者
Gratia, Elisabeth [1 ]
De Herde, Andre [1 ]
机构
[1] Univ Catholique Louvain, B-1348 Louvain, Belgium
关键词
double-skin facade; thermal modelling; office building; shading devices; cooling strategies;
D O I
10.1016/j.enbuild.2006.09.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent years, there has been a great deal of interest in double-skin facades due to the advantages claimed for this technology in terms of energy saving in the cold season, protection from external noise and wind loads and their high-tech image. The advent of computers and other office equipment has increased the internal heat gains in most offices. Highly glazed facades, together with the extra heat gains from the electric lighting made necessary by deep floor plans and the wider use of false ceilings, have increased the risk of overheating. To preserve comfort and reduce cooling loads, it is important to apply natural cooling strategies, including solar protections use. External solar protections are more effective than internal shading devices. In the case of the double-skin facade, the blinds can be integrated in the cavity. It is thus protected from the bad weather and pollution. Solar protection can remain in place even in the event of important wind, which represents an undeniable advantage for the buildings with great height. This article examines the influence of the position and the colour of the blinds on the cooling consumption of an office building with a double-skin facade. (C) 2006 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:364 / 373
页数:10
相关论文
共 50 条
  • [41] Full-scale burning tests on double-skin facade fires
    Chow, C. L.
    FIRE AND MATERIALS, 2013, 37 (01) : 17 - 34
  • [42] Natural cooling strategies efficiency in an office building with a double-skin facade
    Gratia, E
    De Herde, A
    ENERGY AND BUILDINGS, 2004, 36 (11) : 1139 - 1152
  • [43] Evaluating thermal performance of double-skin facade using response factor
    Lee, Seung Woo
    Park, J. S.
    ENERGY AND BUILDINGS, 2020, 209
  • [44] DEVELOPMENT OF THE CAPABILITY OF ENERGYPLUS SOFTWARE TO SIMULATION OF BUILDING DOUBLE-SKIN FACADE
    Sabooni, Mohammad Armin
    Vaseti, Hashem Musavi
    Maerefat, Mehdi
    Azimi, Aziz
    PROCEEDINGS OF SEBUA-12 ICHMT INTERNATIONAL SYMPOSIUM ON SUSTAINABLE ENERGY IN BUILDINGS AND URBAN AREAS, 2012,
  • [45] Structural Performance of Double-Skin Facade Systems Subjected to Blast Pressures
    Tuan Ngo
    Ding, Chao
    Lumantarna, Raymond
    Ghazlan, Abdallah
    Zobec, Marc
    JOURNAL OF STRUCTURAL ENGINEERING, 2015, 141 (12)
  • [46] Modeling ventilation in naturally ventilated double-skin facade with a venetian blind
    Zeng, Zhen
    Li, Xiaofeng
    Li, Cheng
    Zhu, Yingxin
    BUILDING AND ENVIRONMENT, 2012, 57 : 1 - 6
  • [47] Smoke control through a double-skin facade used for natural ventilation
    Ding, Wenting
    Hasemi, Yuji
    ASHRAE TRANSACTIONS 2006, VOL 112, PT 1, 2006, 112 : 181 - +
  • [48] Field measurements on thermal comfort of a building with double-skin facade in winter
    Wang, Fang
    Zhang, Xiaosong
    Li, Shuhong
    Zhu, Wenyun
    Hu, Qu
    Journal of Southeast University (English Edition), 2010, 26 (02) : 292 - 296
  • [49] Experimential investigation of optical properties of double skin facade shading louvers
    Chen, Youming (ymchen@hnu.com), 1600, Science Press (38):
  • [50] THERMAL CHARACTERISTICS AND ENERGY CONSUMPTION ANALYSIS OF AN EXTERNAL RESPIRATION DOUBLE-SKIN FACADE
    Wang, Hanqing
    Chen, Yu
    Kou, Guangxiao
    Wang, Zhiyong
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1534 - 1539