Optimal operation of a south double-skin facade

被引:100
|
作者
Gratia, E [1 ]
De Herde, A [1 ]
机构
[1] Univ Catholique Louvain, B-1348 Louvain, Belgium
关键词
double-skin facade; thermal modelling; office building; natural ventilation; heating strategies; cooling strategies;
D O I
10.1016/j.enbuild.2003.06.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
There is an increasing demand for higher quality office buildings. Occupants and developers of office buildings ask for a healthy and stimulating working environment. Double-skin facades are appropriate when buildings are subject to great external noise and wind loads. A further area of application is in rehabilitation work, when existing facades cannot be renewed, or where this is not desirable. Double-skin facades have a special esthetic of their own, and this can be exploited architecturally to great advantage. However there are still relatively few buildings in which double-skin facades have actually been realized, and there is still too little experience of their behaviour in operation. In this matter, we choose to study a multistory double-skin facades behaviour. Simulations were realized with TAS software on the building proposed in the frame of the subtask A of the Task 27 (performance of solar facade components) of the International Energy Agency. Simulations were performed on the chosen building with and without double-skin facades. We decide to study eight types of days; and we analyze the double-skin facade behaviour for various operations. The thermal behaviours of the building with and without double-skin are compared. The study of these eight cases showed the importance of the dynamic use of the double-skin. The operation of this one must be obligatorily related to the climatic conditions as well external as interior and a bad operation of the double-skin could lead to catastrophic results. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:41 / 60
页数:20
相关论文
共 50 条
  • [1] Greenhouse effect in double-skin facade
    Gratia, Elisabeth
    De Herde, Andre
    [J]. ENERGY AND BUILDINGS, 2007, 39 (02) : 199 - 211
  • [2] Natural ventilation in a double-skin facade
    Gratia, E
    De Herde, A
    [J]. ENERGY AND BUILDINGS, 2004, 36 (02) : 137 - 146
  • [3] Elite Bias Genetic Algorithm for Optimal Control of Double-skin Facade
    Xu Xingtian
    Chen Xi
    [J]. 2015 IEEE CONGRESS ON EVOLUTIONARY COMPUTATION (CEC), 2015, : 3354 - 3361
  • [4] Double-skin facade in Flotran CFD
    Palko, Milan
    [J]. ADVANCED BUILDING CONSTRUCTION AND MATERIALS 2013, 2014, 855 : 154 - 159
  • [5] A Study on the Improvement of Double-Skin Facade Operation for Reducing Heating Load in Winter
    Sung, Uk-Joo
    Kim, Seok-Hyun
    [J]. SUSTAINABILITY, 2019, 11 (22)
  • [6] Effect of annual solar radiation on simple facade, double-skin facade and double-skin facade filled with phase change materials for saving energy
    Alqaed, Saeed
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 51
  • [7] A qualitative investigation on double-skin facade fires
    Chow, C. L.
    [J]. 1ST INTERNATIONAL SEMINAR FOR FIRE SAFETY OF FACADES, 2013, 9
  • [8] Chimney Effect Assessment of the Double-skin Facade
    QIU ZhongzhuLI PengCHOW TintaiREN JianxingWANG WenhuanSchool of Energy Environment EngineeringShanghai University of Electric PowerShanghai ChinaSchool of Mechanical EngineeringTongji UniversityShanghai ChinaDivision of Building Science TechnologyCity University of Hong KongHong Kong SARChina
    [J]. 湖南大学学报(自然科学版)., 2009, 36(S1) (自然科学版) - 150
  • [9] Chimney Effect Assessment of the Double-skin Facade
    QIU Zhong-zhu1
    2.School of Mechanical Engineering
    3.Division of Building Science & Technology
    [J]. 湖南大学学报(自然科学版), 2009, (S1) : 146 - 150
  • [10] Energy Saving Potential of Double-Skin Facade Buildings with Active Adaptive Operation in Winter
    Wang, Fang
    Zhang, Xiaosong
    Liu, Xiaoqin
    [J]. 6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 214 - 221