Wear on joint prostheses is the leading cause of premature failure leading to revision surgery. Tests conducted on mechanical wear simulator show poor performance of prosthetic hip components manufactured using high-quality raw materials. Aiming to understand the phenomena that limit the longevity of joint prostheses, the manufacturing processes of two separate companies were investigated. Results obtained suggest that the lack of control during the manufacturing of the parts may be the reason for the low performance shown by the prostheses tested in the wear simulator. Out-of-roundness and roughness of finished surfaces is pointed out as the main manufacturing failure in production lines tested. Metal femoral heads showed deviations from roundness of up to 32.41 lm (sigma = 8.869) and R-a = 0.295 +/- 0.03, while acetabular cups in ultra-high molecular weight polyethylene showed deviations of up to 166.31 mu m (sigma = 53.982) and R-a = 0.031 +/- 0.02. The out-of-roundness contributes to reducing the contact area between rolling surfaces, increasing tension in regions where premature wear on parts occurs with frequency. This study points out the common faults found in manufacturing processes and suggest changes to increase the longevity of total hip arthroplasty.
引用
收藏
页码:787 / 795
页数:9
相关论文
共 50 条
  • [1] Influence of the manufacturing process in performance concerning wear of total hip prostheses
    A. L. L. Oliveira
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2014, 36 : 787 - 795
  • [2] THE INFLUENCE OF CONTACT STRESS ON THE WEAR OF UHMWPE FOR TOTAL REPLACEMENT HIP PROSTHESES
    BARBOUR, PSM
    BARTON, DC
    FISHER, J
    WEAR, 1995, 181 : 250 - 257
  • [3] STUDY OF WEAR RESISTANT MATERIALS FOR TOTAL HIP PROSTHESES
    SHEN, C
    DUMBLETO.J
    MILLER, E
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1974, A 56 (04): : 847 - 847
  • [4] The Appropriate Variable to Compare Wear in Total Hip Prostheses
    Burstein, Albert H.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (21):
  • [5] APPLICATION OF AN ANALYTICAL WEAR MODEL TO TOTAL HIP PROSTHESES
    DUMBLETON, JH
    WEAR, 1973, 26 (02) : 277 - 279
  • [6] Polyethylene wear in total hip prostheses: the influence of direction of linear wear on volumetric wear determined from radiographic data
    Kosak, R
    Antolic, V
    Pavlovcic, V
    Kralj-Iglic, V
    Milosev, I
    Vidmar, G
    Iglic, A
    SKELETAL RADIOLOGY, 2003, 32 (12) : 679 - 686
  • [7] Polyethylene wear in total hip prostheses: the influence of direction of linear wear on volumetric wear determined from radiographic data
    R. Košak
    V. Antolič
    V. Pavlovčič
    V. Kralj-Iglič
    I. Milošev
    G. Vidmar
    A. Iglič
    Skeletal Radiology, 2003, 32 : 679 - 686
  • [8] The wear of metal-on-metal total hip prostheses measured in a hip simulator
    Scholes, SC
    Green, SM
    Unsworth, A
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2001, 215 (H6) : 523 - 530
  • [9] The effects of polyethylene cup thickness on wear of total hip prostheses
    Oonishi, H
    Iwaki, H
    Kin, N
    Kushitani, S
    Murata, N
    Wakitani, S
    Imoto, K
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1998, 9 (08) : 475 - 478
  • [10] Wear prediction of total hip prostheses due to common activities
    Onisoru, Justin
    Enescu, Nicolae
    Iarovici, Aron
    Capitanu, Lucian
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCE AND INFORMATION IN ENGINEERING CONFERENCE, VOL 1, PTS A-C, 2008, : 717 - 724