Influence of the manufacturing process in performance concerning wear of total hip prostheses

被引:2
|
作者
Oliveira, A. L. L. [1 ]
机构
[1] Univ Sao Paulo, Dept Mech Engn, BR-2231 Sao Paulo, Brazil
关键词
Total hip prostheses; Manufacturing process; Quality control; Roundness; Roughness; Tribology; MOLECULAR-WEIGHT POLYETHYLENE; BEARING SURFACE; ARTHROPLASTY; JOINTS; REPLACEMENTS; ROUGHNESS; CEMENT;
D O I
10.1007/s40430-013-0123-x
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Wear on joint prostheses is the leading cause of premature failure leading to revision surgery. Tests conducted on mechanical wear simulator show poor performance of prosthetic hip components manufactured using high-quality raw materials. Aiming to understand the phenomena that limit the longevity of joint prostheses, the manufacturing processes of two separate companies were investigated. Results obtained suggest that the lack of control during the manufacturing of the parts may be the reason for the low performance shown by the prostheses tested in the wear simulator. Out-of-roundness and roughness of finished surfaces is pointed out as the main manufacturing failure in production lines tested. Metal femoral heads showed deviations from roundness of up to 32.41 lm (sigma = 8.869) and R-a = 0.295 +/- 0.03, while acetabular cups in ultra-high molecular weight polyethylene showed deviations of up to 166.31 mu m (sigma = 53.982) and R-a = 0.031 +/- 0.02. The out-of-roundness contributes to reducing the contact area between rolling surfaces, increasing tension in regions where premature wear on parts occurs with frequency. This study points out the common faults found in manufacturing processes and suggest changes to increase the longevity of total hip arthroplasty.
引用
收藏
页码:787 / 795
页数:9
相关论文
共 50 条
  • [31] Retrieved total hip prostheses Part II Wear behaviour and structural changes
    H. Oonishi
    E. Tsuji
    Y.Y. Kim
    Journal of Materials Science: Materials in Medicine, 1998, 9 : 575 - 581
  • [32] Wear of cast metal-metal pairs for total replacement hip prostheses
    Hernández-Rodríguez, MAL
    Mercado-Solís, RD
    Pérez-Unzueta, A
    Martinez-Delgado, DI
    Cantú-Sifuentes, M
    WEAR, 2005, 259 : 958 - 963
  • [33] Friction and wear testing of DLC type coatings on total hip replacement prostheses
    Jones, AHS
    Taylor, SK
    Teer, DG
    Elloy, M
    FRICTION, LUBRICATION, AND WEAR OF ARTIFICIAL JOINTS, 2003, : 99 - 112
  • [34] Influence of simulator kinematics on the wear of metal-on-metal hip prostheses
    Firkins, PJ
    Tipper, JL
    Ingham, E
    Stone, MH
    Farrar, R
    Fisher, J
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2001, 215 (H1) : 119 - 121
  • [35] 530 TOTAL HIP PROSTHESES
    PICAULT, C
    MOULIN, Y
    MOUILLES.B
    BOLZE, O
    LYON CHIRURGICAL, 1973, 69 (06) : 437 - 442
  • [36] INFECTIONS OF TOTAL HIP PROSTHESES
    EVRARD, J
    REVUE DU RHUMATISME, 1986, 53 (02): : 109 - 112
  • [37] 600 TOTAL HIP PROSTHESES
    PICAULT, C
    IMBERT, JC
    MOULIN, Y
    MOUILLES.B
    LYON MEDICAL, 1973, 229 (06): : 621 - 622
  • [38] THE FIXATION OF TOTAL HIP PROSTHESES
    LEE, AJC
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1983, 19 (12): : 1117 - 1117
  • [39] LUXATION OF TOTAL HIP PROSTHESES
    LABURTHETOLRA, Y
    CHIRURGIE, 1983, 109 (09): : 785 - 789
  • [40] Fractures between total hip prostheses and total knee prostheses.
    Hulet, C.
    Lautridou, C.
    Lebel, B.
    Brihault, J.
    Burdin, P.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2006, 92 : 79 - 82