Validation of dose painting of lung tumours using alanine/EPR dosimetry

被引:7
|
作者
Knudtsen, Ingerid Skjei [1 ,2 ]
Svestad, Jorund Graadal [1 ]
Sande, Erlend Peter Skaug [2 ]
Rekstad, Bernt Louni [2 ]
Rodal, Jan [2 ]
van Elmpt, Wouter [3 ]
Ollers, Michel [3 ]
Hole, Eli Olaug [1 ]
Malinen, Eirik [1 ,2 ]
机构
[1] Univ Oslo, Dept Phys, POB 1048 Blindern, N-0316 Oslo, Norway
[2] Oslo Univ Hosp, Dept Med Phys, POB 4953 Nydalen, N-0424 Oslo, Norway
[3] Maastricht Univ, Med Ctr, GROW Sch Oncol & Dev Biol, Dept Radiat Oncol MAASTRO, POB 3035, NL-6202 NA Maastricht, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 06期
关键词
radiotherapy; lung cancer; phantom; IMRT; VMAT; PET; functional imaging; POSITRON-EMISSION-TOMOGRAPHY; PHOTON BEAMS; NECK-CANCER; MONTE-CARLO; CALCULATION ALGORITHMS; SMALL FIELDS; ACUROS XB; RADIOTHERAPY; THERAPY; PHANTOM;
D O I
10.1088/0031-9155/61/6/2243
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Biologic image guided radiotherapy (RT) with escalated doses to tumour sub volumes challenges today's RT dose planning and delivery systems. In this phantom study, we verify the capability of a clinical dose planning and delivery system to deliver an F-18-FDG-PET based dose painted treatment plan to a lung tumour. Furthermore, we estimate the uncertainties of the dose painted treatment compared to conventional RT plans. An anthropomorphic thorax phantom of polystyrene and polyurethane was constructed based on CT images of a lung cancer patient. 101 EPR/alanine dosimeters were placed in separate cavities within the phantom. IMRT and VMAT plans were generated in Eclipse (version 10.0, Analytical Anisotropic Algorithm version 10.2.28, Varian Medical Systems, Inc.) for 6 and 15 MV photons, based on F-18-FDG-PET/CT images of the patient. A boost dose of 3.8 Gy/fraction was given to the F-18-FDG-avid region (biological planning volume; BTV), whereas 3.1 Gy/fraction was planned to the planning target volume (PTV, excluding the BTV). For the homogenous plans, 3.2 Gy/fraction was given to the PTV. Irradiation of the phantom was carried out at a Varian Trilogy linear accelerator (Varian Medical Systems, Inc.). Uncertainties involved in treatment planning and delivery were estimated from portal dosimetry gamma evalutation. Measured and calculated doses were compared by Bland-Altmann analysis. For all treatment plans, all dose-volume objectives could be achieved in the treatment planning system. The mean absolute differences between calculated and measured doses were small (<0.1 Gy) for BTV, PTV-BTV, lung and soft tissue. The estimated uncertainty of the planned doses was less than 3% for all plans, whereas the estimated uncertainty in the measured doses was less 2.3%. Our results show that planning and delivery of dose escalated lung cancer treatment on a clinical dose planning and delivery system has high dosimetric accuracy. The uncertainties associated with the dose escalated treatment plans are comparable to the conventional plans.
引用
收藏
页码:2243 / 2254
页数:12
相关论文
共 50 条
  • [1] Dose verification and calibration of the Cyberknife® by EPR/alanine dosimetry
    Garcia, Tristan
    Lacornerie, Thomas
    Popoff, Romain
    Lourenco, Valerie
    Bordy, Jean-Marc
    RADIATION MEASUREMENTS, 2011, 46 (09) : 952 - 957
  • [2] Dosimetry audit for tomotherapy using alanine/EPR
    Duane, S.
    Nicholas, D.
    Palmans, H.
    Schaeken, B.
    Sephton, J.
    Sharpe, P.
    Thomas, R.
    Tomsej, M.
    Tournel, K.
    Verellen, D.
    Vynckier, S.
    MEDICAL PHYSICS, 2006, 33 (06) : 2093 - 2094
  • [3] Epr/alanine dosimetry: Just another dose measuring system?
    Schaeken, B
    Goor, C
    Scalliet, P
    EUROPEAN JOURNAL OF CANCER, 1995, 31A : 142 - 142
  • [4] Alanine EPR dosimetry in brachytherapy
    De Angelis, C
    Onori, S
    Petetti, E
    Piermattei, A
    Azario, L
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (05): : 1181 - 1191
  • [5] Positron emission tomography guided dose painting by numbers of lung cancer: Alanine dosimetry in an anthropomorphic phantom
    Papoutsis, Iosif
    Knudtsen, Ingerid Skjei
    Sande, Erlend Peter Skaug
    Rekstad, Bernt Louni
    Ollers, Michel
    van Elmpt, Wouter
    Arnesen, Marius Rothe
    Malinen, Eirik
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 21 : 101 - 107
  • [6] A Practical Method for EPR Dosimetry Using Alanine Powder
    Hassan, Amna
    Tzivaki, Margarita
    Felner, Lukas
    Waller, Edward
    HEALTH PHYSICS, 2022, 123 (04): : 325 - 331
  • [7] Ir-192HDR transit dose and radial dose function determination using alanine/EPR dosimetry
    Calcina, CSG
    de Almeida, A
    Rocha, JRO
    Abrego, FC
    Baffa, O
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (06): : 1109 - 1117
  • [8] Absolute calibration of the Gamma Knife® Perfexion™ and delivered dose verification using EPR/alanine dosimetry
    Hornbeck, Amaury
    Garcia, Tristan
    Cuttat, Marguerite
    Jenny, Catherine
    MEDICAL PHYSICS, 2014, 41 (06)
  • [9] Calibration of helical tomotherapy machine using EPR/alanine dosimetry
    Perichon, Nicolas
    Garcia, Tristan
    Francois, Pascal
    Lourenco, Valerie
    Lesven, Caroline
    Bordy, Jean-Marc
    MEDICAL PHYSICS, 2011, 38 (03) : 1168 - 1177
  • [10] Medical reference dosimetry using EPR measurements of alanine: Development of an improved method for clinical dose levels.
    Helt-Hansen, Jakob
    Rosendal, Flemming
    Kofoed, Inger Matilde
    Andersen, Claus Erik
    ACTA ONCOLOGICA, 2009, 48 (02) : 216 - 222