Validation of dose painting of lung tumours using alanine/EPR dosimetry

被引:7
|
作者
Knudtsen, Ingerid Skjei [1 ,2 ]
Svestad, Jorund Graadal [1 ]
Sande, Erlend Peter Skaug [2 ]
Rekstad, Bernt Louni [2 ]
Rodal, Jan [2 ]
van Elmpt, Wouter [3 ]
Ollers, Michel [3 ]
Hole, Eli Olaug [1 ]
Malinen, Eirik [1 ,2 ]
机构
[1] Univ Oslo, Dept Phys, POB 1048 Blindern, N-0316 Oslo, Norway
[2] Oslo Univ Hosp, Dept Med Phys, POB 4953 Nydalen, N-0424 Oslo, Norway
[3] Maastricht Univ, Med Ctr, GROW Sch Oncol & Dev Biol, Dept Radiat Oncol MAASTRO, POB 3035, NL-6202 NA Maastricht, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 06期
关键词
radiotherapy; lung cancer; phantom; IMRT; VMAT; PET; functional imaging; POSITRON-EMISSION-TOMOGRAPHY; PHOTON BEAMS; NECK-CANCER; MONTE-CARLO; CALCULATION ALGORITHMS; SMALL FIELDS; ACUROS XB; RADIOTHERAPY; THERAPY; PHANTOM;
D O I
10.1088/0031-9155/61/6/2243
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Biologic image guided radiotherapy (RT) with escalated doses to tumour sub volumes challenges today's RT dose planning and delivery systems. In this phantom study, we verify the capability of a clinical dose planning and delivery system to deliver an F-18-FDG-PET based dose painted treatment plan to a lung tumour. Furthermore, we estimate the uncertainties of the dose painted treatment compared to conventional RT plans. An anthropomorphic thorax phantom of polystyrene and polyurethane was constructed based on CT images of a lung cancer patient. 101 EPR/alanine dosimeters were placed in separate cavities within the phantom. IMRT and VMAT plans were generated in Eclipse (version 10.0, Analytical Anisotropic Algorithm version 10.2.28, Varian Medical Systems, Inc.) for 6 and 15 MV photons, based on F-18-FDG-PET/CT images of the patient. A boost dose of 3.8 Gy/fraction was given to the F-18-FDG-avid region (biological planning volume; BTV), whereas 3.1 Gy/fraction was planned to the planning target volume (PTV, excluding the BTV). For the homogenous plans, 3.2 Gy/fraction was given to the PTV. Irradiation of the phantom was carried out at a Varian Trilogy linear accelerator (Varian Medical Systems, Inc.). Uncertainties involved in treatment planning and delivery were estimated from portal dosimetry gamma evalutation. Measured and calculated doses were compared by Bland-Altmann analysis. For all treatment plans, all dose-volume objectives could be achieved in the treatment planning system. The mean absolute differences between calculated and measured doses were small (<0.1 Gy) for BTV, PTV-BTV, lung and soft tissue. The estimated uncertainty of the planned doses was less than 3% for all plans, whereas the estimated uncertainty in the measured doses was less 2.3%. Our results show that planning and delivery of dose escalated lung cancer treatment on a clinical dose planning and delivery system has high dosimetric accuracy. The uncertainties associated with the dose escalated treatment plans are comparable to the conventional plans.
引用
收藏
页码:2243 / 2254
页数:12
相关论文
共 50 条
  • [21] A unique calibration curve for alanine EPR dosimetry systems
    Wieser, A
    Girzikowsky, R
    APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) : 1269 - 1275
  • [22] Commissioning a compact, tabletop EPR spectrometer for alanine dosimetry
    Smith, Blake R.
    Khan, Ahtesham
    Culberson, Wesley S.
    RADIATION MEASUREMENTS, 2021, 146
  • [23] Sand for high-dose dosimetry using the EPR technique
    Teixeira, MI
    Ferraz, GM
    Caldas, LVE
    APPLIED RADIATION AND ISOTOPES, 2005, 62 (02) : 359 - 363
  • [24] Determination of boron dose for BNCT using Fricke and EPR dosimetry
    Wielopolski, L
    Ciesielski, B
    CANCER NEUTRON CAPTURE THERAPY, 1996, : 467 - 471
  • [25] Alanine dosimetry in dose verification for IMRT
    Schaeken, B.
    De Ost, B.
    Van Gestel, D.
    Meijnders, P.
    Jacobs, I.
    Goor, C.
    Vanderkam, S.
    Coelmont, A.
    Van den Weyngaert, D.
    Schaeken, B.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S365 - S366
  • [26] Alanine/EPR dosimetry applied to the verification of a total body irradiation protocol and treatment planning dose calculation using a humanoid phantom
    Schaeken, B.
    Lelie, S.
    Meijnders, P.
    Van den Weyngaert, D.
    Janssens, H.
    Verellen, D.
    MEDICAL PHYSICS, 2010, 37 (12) : 6292 - 6299
  • [27] Dose assurance service for low energy X-ray irradiators using an alanine-EPR transfer dosimetry system
    Khoury, Helen J.
    Mehta, Kishor
    de Barros, Vinicius S.
    Guzzo, Pedro L.
    Parker, Andrew G.
    FLORIDA ENTOMOLOGIST, 2016, 99 : 14 - 17
  • [28] DOSE PAINTING: HOW AND FOR WHICH TUMOURS?
    Khoo, V.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S121 - S121
  • [29] Characteristics of a Compact Tabletop Alanine EPR System for Clinical Dosimetry
    Smith, B.
    Culberson, W.
    MEDICAL PHYSICS, 2020, 47 (06) : E452 - E452
  • [30] EPR/ALANINE PELLETS WITH LOW Gd CONTENT FOR NEUTRON DOSIMETRY
    Marrale, M.
    Brai, M.
    Longo, A.
    Panzeca, S.
    Carlino, A.
    Tranchina, L.
    Tomarchio, E.
    Parlato, A.
    Buttafava, A.
    Dondi, D.
    Zeffiro, A.
    RADIATION PROTECTION DOSIMETRY, 2014, 161 (1-4) : 383 - 386