Partial discharge detection of continuous length wire

被引:0
|
作者
Rush, Jim L. [1 ]
机构
[1] Teledyne Reynolds Inc, Los Angeles, CA 90066 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The ability to eliminate or minimize defects in high voltage wire can help in extending system reliability by eliminating or minimizing sources of partial discharge. Partial discharge testing of single conductor wire is traditionally performed on discrete lengths of wire or wires terminated to connectors. However, when excessive partial discharge is detected in completed assemblies, expensive rework is the result. Eliminating defects, prior to connector termination and testing, would be beneficial. Existing partial discharge detection methods of wire require the termination of fixed lengths to temporary test connectors. The wire must have a braided shield or similar ground conductor placed around its outer diameter and fixed to the connector. These test connector terminations must be constructed carefully, since discharges resulting from poor terminations cannot easily be differentiated from discharges produced within the wire. Additionally, discharges found within the wire cannot always be localized for removal. A method is presented for partial discharge pulse detection in continuous length wires. Detection of partial discharges may indicate the presence of electrical insulation defects which may result in overstressing by an electric field and/or the occurrence of transient gas ionization, which will erode the insulation and ultimately lead to a reduction in wire reliability and life. This test method offers the advantage of locating wire insulation defects in process, such as small voids, fractures, and separations prior to termination which then can be cut from the spool of wire or otherwise identified. Electrostatic models of the system are analyzed and testing results are discussed related to fluoropolymer insulated wires. A conductor cleaning process and optical detection apparatus, intended to minimize or identify insulation defects caused by contamination, is also presented.
引用
收藏
页码:71 / 74
页数:4
相关论文
共 50 条
  • [41] Detection of partial discharge in the high voltage apparatus
    Zheng, DC
    Zhang, CX
    Chen, CT
    Yu, CS
    Yang, JX
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 323 - 326
  • [42] Partial Discharge Development and Detection in Dielectric Liquids
    Pompili, Massimo
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2009, 16 (06) : 1648 - 1654
  • [43] Fiber optic sensor for partial discharge detection
    Czyzewski, Adam
    Litwin, Dariusz
    Czerwinski, Szymon
    Kucharek, Mariusz
    Michalski, Pawel
    Leistner, Andre
    Stier, Marina
    Klose-Stier, Alexandra
    Leistner, Aleksandra
    Leistner, Aniela
    PRZEGLAD ELEKTROTECHNICZNY, 2024, 100 (07): : 276 - 279
  • [44] Elliptical UHF sensor for partial discharge detection
    Lira, Ruann Victor de Andrade
    Campos, Antonio Luiz Pereira de Siqueira
    Neto, Alfredo Gomes
    Silva Jr, Isau de Souza
    Serres, Alexandre Jean Rene
    Nobrega, Luiz Augusto Medeiros Martins
    Silva, Allan David da Costa
    Carvalho, Itaiara Felix
    SENSORS AND ACTUATORS A-PHYSICAL, 2022, 348
  • [45] Electromagnetic coupling method for partial discharge detection
    Wong, K. L.
    Spoor, D. J.
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 3023 - +
  • [46] Experience with Acoustic Sensors in Partial Discharge Detection
    Shaker, Yomna
    Zahed, Abdalmonam
    El-Hag, Ayman
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [47] Partial discharge detection and localization in power transformers
    Gockenbach, E
    2004 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2004, : 466 - 469
  • [48] Detection and Monitoring of Partial Discharge of a Power Line
    Cern, Y.
    MATERIALS EVALUATION, 2010, 68 (02) : 145 - 145
  • [49] New method for partial discharge signals detection
    Li Y.-F.
    Wang B.-B.
    Feng X.-C.
    Xi'an Dianzi Keji Daxue Xuebao/Journal of Xidian University, 2010, 37 (03): : 529 - 533+569
  • [50] RF detection of partial discharge in current transformer
    Chen, Mu-Kuen
    Chang, Wen-Yeau
    Chen, Jeng-Ming
    Cheng, Chao-Yuan
    2007 CONFERENCE PROCEEDINGS IPEC, VOLS 1-3, 2007, : 193 - 196