Partial discharge detection of continuous length wire

被引:0
|
作者
Rush, Jim L. [1 ]
机构
[1] Teledyne Reynolds Inc, Los Angeles, CA 90066 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The ability to eliminate or minimize defects in high voltage wire can help in extending system reliability by eliminating or minimizing sources of partial discharge. Partial discharge testing of single conductor wire is traditionally performed on discrete lengths of wire or wires terminated to connectors. However, when excessive partial discharge is detected in completed assemblies, expensive rework is the result. Eliminating defects, prior to connector termination and testing, would be beneficial. Existing partial discharge detection methods of wire require the termination of fixed lengths to temporary test connectors. The wire must have a braided shield or similar ground conductor placed around its outer diameter and fixed to the connector. These test connector terminations must be constructed carefully, since discharges resulting from poor terminations cannot easily be differentiated from discharges produced within the wire. Additionally, discharges found within the wire cannot always be localized for removal. A method is presented for partial discharge pulse detection in continuous length wires. Detection of partial discharges may indicate the presence of electrical insulation defects which may result in overstressing by an electric field and/or the occurrence of transient gas ionization, which will erode the insulation and ultimately lead to a reduction in wire reliability and life. This test method offers the advantage of locating wire insulation defects in process, such as small voids, fractures, and separations prior to termination which then can be cut from the spool of wire or otherwise identified. Electrostatic models of the system are analyzed and testing results are discussed related to fluoropolymer insulated wires. A conductor cleaning process and optical detection apparatus, intended to minimize or identify insulation defects caused by contamination, is also presented.
引用
收藏
页码:71 / 74
页数:4
相关论文
共 50 条
  • [31] Detection of Partial Discharge in Liquid via Interferometry
    Xue, Liang
    Zhou, Hao
    Wang, Wenjing
    Chen, Junjie
    Qin, Lunming
    Jiang, Chao
    Cui, Haoyang
    IEEE PHOTONICS JOURNAL, 2024, 16 (05): : 1 - 10
  • [32] Wideband UHF Antenna for Partial Discharge Detection
    Cui, Zhen
    Park, Seungyong
    Choo, Hosung
    Jung, Kyung-Young
    APPLIED SCIENCES-BASEL, 2020, 10 (05):
  • [33] DC partial discharge detection and analysis techniques
    Mathes, JB
    Whelan, TJ
    Uhlrich, CJ
    2002 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2002, : 736 - 739
  • [34] PARTIAL DISCHARGE DETECTION - THEORETICAL AND PRACTICAL ASPECTS
    PEDERSEN, A
    CRICHTON, GC
    MCALLISTER, IW
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1995, 142 (01) : 29 - 36
  • [35] General consideration for the partial discharge detection sensitivity
    Matsumoto, S
    Umemura, T
    Okubo, H
    Fréchette, MF
    Hudon, C
    GASEOUS DIELECTRICS IX, 2001, : 251 - 256
  • [36] Tuning balance method of partial discharge detection
    Liu, G
    Fang, XD
    Tu, DM
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 709 - 712
  • [37] Partial discharge detection and location in cable joint
    Wu, XY
    Xie, HK
    Peng, ZR
    Pang, QP
    1998 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS, PROCEEDINGS, 1998, : 721 - 723
  • [38] A Robot Used for Partial Discharge Detection of Switchgear
    Luan, Yiqing
    Xu, Wei
    Huang, Rui
    Li, Jianxiang
    Wang, Haipeng
    2017 INTERNATIONAL CONFERENCE ON COMPUTER SYSTEMS, ELECTRONICS AND CONTROL (ICCSEC), 2017, : 823 - 827
  • [39] On-line partial discharge detection in cables
    Ahmed, NH
    Srinivas, NN
    IEEE 1997 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I AND II, 1997, : 214 - 217
  • [40] Partial discharge detection in modern power grid
    Liska, Jindrich
    Jakl, Jan
    Kunkel, Sven
    Stastny, Ladislav
    Mego, Roman
    2022 INTERNATIONAL CONFERENCE ON DIAGNOSTICS IN ELECTRICAL ENGINEERING (DIAGNOSTIKA), 2022, : 180 - 183