Rapid 2D variable flip angle method for accurate and precise T1 measurements over a wide range of T1 values

被引:1
|
作者
Lena, Beatrice [1 ,2 ]
Bos, Clemens [2 ]
Ferrer, Cyril J. [2 ]
Moonen, Chrit T. W. [2 ]
Viergever, Max A. [1 ]
Bartels, Lambertus W. [1 ,2 ]
机构
[1] Univ Med Ctr Utrecht, Image Sci Inst, Imaging & Oncol Div, Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Imaging & Oncol Div, Image Guided Mol Intervent Grp, Utrecht, Netherlands
关键词
slice excitation profile; T-1; mapping; variable flip angle;
D O I
10.1002/nbm.4542
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Purpose To perform dynamic T-1 mapping using a 2D variable flip angle (VFA) method, a correction for the slice profile effect is needed. In this work we investigated the impact of flip angle selection and excitation RF pulse profile on the performance of slice profile correction when applied to T-1 mapping over a range of T-1 values. Methods A correction of the slice profile effect is proposed, based on Bloch simulation of steady-state signals. With this correction, Monte Carlo simulations were performed to assess the accuracy and precision of 2D VFA T-1 mapping in the presence of noise, for RF pulses with time-bandwidth products of 2, 3 and 10 and with flip angle pairs in the range [1 degrees-90 degrees]. To evaluate its performance over a wide range of T-1, maximum errors were calculated for six T-1 values between 50 ms and 1250 ms. The method was demonstrated using in vitro and in vivo experiments. Results Without corrections, 2D VFA severely underestimates T-1. Slice profile errors were effectively reduced with the correction based on simulations, both in vitro and in vivo. The precision and accuracy of the method depend on the nominal T-1 values, the FA pair, and the RF pulse shape. FA pairs leading to T-1 can be identified for the common RF shapes, for T-1 values between 50 ms and 1250 ms. Conclusions 2D VFA T-1 mapping with Bloch-simulation-based correction can deliver T-1 estimates that are accurate and precise to within 5% over a wide T-1 range.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] A rapid measurement of T1/T2: The DECPMG sequence
    Mitchell, J.
    Huerlimann, M. D.
    Fordham, E. J.
    JOURNAL OF MAGNETIC RESONANCE, 2009, 200 (02) : 198 - 206
  • [42] In vivo 5-fluorouracil and fluoronucleotide T1 relaxation time measurements using the variable nutation angle method
    Gade, TPF
    Spees, WM
    Le, HC
    Zakian, KL
    Ponomarev, V
    Doubrovin, M
    Gelovani, JG
    Koutcher, JA
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) : 169 - 173
  • [43] Measurements of water diffusion and T1 values in peritumoural oedematous brain
    Bastin, ME
    Sinha, S
    Whittle, AR
    Wardlaw, JM
    NEUROREPORT, 2002, 13 (10) : 1335 - 1340
  • [44] The application of B1 inhomogeneity-corrected variable flip angle T1 mapping for assessing liver fibrosis
    Zou, Jie
    Jiang, Yanli
    Fan, Fengxian
    Yang, Pin
    Gan, Tiejun
    Yang, Tingli
    Li, Min
    Ding, Yuan
    Wang, Shaoyu
    Zhang, Jing
    MAGNETIC RESONANCE IMAGING, 2024, 113
  • [45] An efficient reconstruction of 2D-tiling with t1,2, t2,1, t1,1 tiles
    Vedhanayagam, Masilamani
    Krithivasan, Kamala
    COMBINATORIAL IMAGE ANALYSIS, PROCEEDINGS, 2006, 4040 : 474 - 480
  • [46] 3D magnetic resonance fingerprinting for rapid simultaneous T1, T2, and T1ρ volumetric mapping of human articular cartilage at 3 T
    Sharafi, Azadeh
    Zibetti, Marcelo V. W.
    Chang, Gregory
    Cloos, Martijn
    Regatte, Ravinder R.
    NMR IN BIOMEDICINE, 2022, 35 (12)
  • [47] Relaxation by Amplitude Modulation: A Rapid T1 Measurement Method
    Zou, Xiaowei
    Brown, Truman R.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (06) : 2155 - 2165
  • [48] Novel method for rapid, simultaneous T1, T2*, and proton density quantification
    Warntjes, J. B. M.
    Dahlqvist, O.
    Lundberg, P.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (03) : 528 - 537
  • [49] Variable Flip Angle 3D Ultrashort Echo Time (UTE) T1 Mapping of Mouse Lung: A Repeatability Assessment
    Alamidi, Daniel F.
    Smailagic, Amir
    Bidar, Abdel W.
    Parker, Nicole S.
    Olsson, Marita
    Hockings, Paul D.
    Lagerstrand, Kerstin M.
    Olsson, Lars E.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 48 (03) : 846 - 852
  • [50] Comparison and calibration of MP2RAGE quantitative T1 values to multi-TI inversion recovery T1 values
    Saunders, Adam M.
    Kim, Michael E.
    Gao, Chenyu
    Remedios, Lucas W.
    Krishnan, Aravind R.
    Schilling, Kurt G.
    O'Grady, Kristin P.
    Smith, Seth A.
    Landman, Bennett A.
    MAGNETIC RESONANCE IMAGING, 2025, 117