Rapid 2D variable flip angle method for accurate and precise T1 measurements over a wide range of T1 values

被引:1
|
作者
Lena, Beatrice [1 ,2 ]
Bos, Clemens [2 ]
Ferrer, Cyril J. [2 ]
Moonen, Chrit T. W. [2 ]
Viergever, Max A. [1 ]
Bartels, Lambertus W. [1 ,2 ]
机构
[1] Univ Med Ctr Utrecht, Image Sci Inst, Imaging & Oncol Div, Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Imaging & Oncol Div, Image Guided Mol Intervent Grp, Utrecht, Netherlands
关键词
slice excitation profile; T-1; mapping; variable flip angle;
D O I
10.1002/nbm.4542
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Purpose To perform dynamic T-1 mapping using a 2D variable flip angle (VFA) method, a correction for the slice profile effect is needed. In this work we investigated the impact of flip angle selection and excitation RF pulse profile on the performance of slice profile correction when applied to T-1 mapping over a range of T-1 values. Methods A correction of the slice profile effect is proposed, based on Bloch simulation of steady-state signals. With this correction, Monte Carlo simulations were performed to assess the accuracy and precision of 2D VFA T-1 mapping in the presence of noise, for RF pulses with time-bandwidth products of 2, 3 and 10 and with flip angle pairs in the range [1 degrees-90 degrees]. To evaluate its performance over a wide range of T-1, maximum errors were calculated for six T-1 values between 50 ms and 1250 ms. The method was demonstrated using in vitro and in vivo experiments. Results Without corrections, 2D VFA severely underestimates T-1. Slice profile errors were effectively reduced with the correction based on simulations, both in vitro and in vivo. The precision and accuracy of the method depend on the nominal T-1 values, the FA pair, and the RF pulse shape. FA pairs leading to T-1 can be identified for the common RF shapes, for T-1 values between 50 ms and 1250 ms. Conclusions 2D VFA T-1 mapping with Bloch-simulation-based correction can deliver T-1 estimates that are accurate and precise to within 5% over a wide T-1 range.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] New Approach to Analyze 2D Map T1–T2
    E. I. Uskova
    M. M. Doroginitskii
    V. D. Skirda
    I. H. Fatkhutdinov
    Applied Magnetic Resonance, 2020, 51 : 183 - 193
  • [32] A method for rapid in vivo measurement of blood T1
    Varela, Marta
    Hajnal, Joseph V.
    Petersen, Esben T.
    Golay, Xavier
    Merchant, Nazakat
    Larkman, David J.
    NMR IN BIOMEDICINE, 2011, 24 (01) : 80 - 88
  • [33] Bias, Repeatability and Reproducibility of Liver T1 Mapping With Variable Flip Angles
    Tadimalla, Sirisha
    Wilson, Daniel J.
    Shelley, David
    Bainbridge, Gavin
    Saysell, Margaret
    Mendichovszky, Iosif A.
    Graves, Martin J.
    Guthrie, J. Ashley
    Waterton, John C.
    Parker, Geoffrey J. M.
    Sourbron, Steven P.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 56 (04) : 1042 - 1052
  • [34] Spatially regularized T1 estimation from variable flip angles MRI
    Wang, Hesheng
    Cao, Yue
    MEDICAL PHYSICS, 2012, 39 (07) : 4139 - 4148
  • [35] NOVIFAST: A Fast Algorithm for Accurate and Precise VFA MRI T1 Mapping
    Ramos-Llorden, Gabriel
    Vegas-Sanchez-Ferrero, Gonzalo
    Bjork, Marcus
    Vanhevel, Floris
    Parizel, Paul M.
    Estepar, Raul San Jose
    den Dekker, Arnold J.
    Sijbers, Jan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (11) : 2414 - 2427
  • [36] Numerical simulation of (T2, T1) 2D NMR and fluid responses
    Mao-Jin Tan
    You-Long Zou
    Jin-Yan Zhang
    Xin Zhao
    Applied Geophysics, 2012, 9 : 401 - 413
  • [37] T1 estimation for aqueous iron oxide nanoparticle suspensions using a variable flip angle SWIFT sequence
    Wang, Luning
    Corum, Curtis A.
    Idiyatullin, Djaudat
    Garwood, Michael
    Zhao, Qun
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (02) : 341 - 347
  • [38] T1 pelvic angle is associated with rapid progression of hip arthrosis
    Kaito Nakamura
    Yoshinori Okamoto
    Hitoshi Wakama
    Junya Matsuyama
    Takashi Ishitani
    Shuhei Otsuki
    Masashi Neo
    European Spine Journal, 2023, 32 : 1463 - 1470
  • [39] T1 pelvic angle is associated with rapid progression of hip arthrosis
    Nakamura, Kaito
    Okamoto, Yoshinori
    Wakama, Hitoshi
    Matsuyama, Junya
    Ishitani, Takashi
    Otsuki, Shuhei
    Neo, Masashi
    EUROPEAN SPINE JOURNAL, 2023, 32 (04) : 1463 - 1470
  • [40] T1 and T2 measurements of the neonatal brain at 7 T
    Mahmoud, Aiman
    Tomi-Tricot, Raphael
    Leitao, David
    Bridgen, Philippa
    Price, Anthony N.
    Uus, Alena
    Boutillon, Arnaud
    Lawrence, Andrew J.
    Cromb, Daniel
    Cawley, Paul
    Deprez, Maria
    De Vita, Enrico
    Giles, Sharon L.
    Rutherford, Mary A.
    Edwards, A. David
    Hajnal, Joseph V.
    Arichi, Tomoki
    Malik, Shaihan J.
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (05) : 2153 - 2162