Wear simulation of the ProDisc-L disc replacement using adaptive finite element analysis

被引:29
|
作者
Rawlinson, Jeremy J. [1 ]
Punga, Karan P.
Gunsallus, Kirk L.
Bartel, Donald L.
Wright, Timothy M.
机构
[1] Cornell Univ, Coll Vet Med, Dept Clin Sci, Ithaca, NY 14853 USA
[2] Cornell Univ, Hosp Special Surg, Program Biomech Engn, Ithaca, NY 14853 USA
[3] Hosp Special Surg, Dept Biomech, New York, NY 10021 USA
关键词
abrasive wear simulation; finite element analysis intervertebral; disc replacement; polyethylene; ProDisc-L; wear testing;
D O I
10.3171/SPI-07/08/166
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. An understanding of the wear potential of total disc replacements (TDRs) is critical as these new devices are increasingly introduced into clinical practice. The authors analyzed the wear potential of a ProDisc-L implant using an adaptive finite element (FE) technique in a computational simulation representing a physical wear test. Methods. The framework for calculating abrasive wear, first validated using a model of a total hip replacement (THR), was then used to model the ProDisc-L polyethylene component that is fixed to the inferior endplate and articulates with the rigid superior endplate. Proposed standards for spine wear testing protocols specified the inputs of flexion-extension (6/-3 degrees), lateral bending (+/- 2 degrees), axial twist (+/- 1.5 degrees), and axial load (200-1750 N or 600-2000 N) applied to the model through 10 million simulation cycles. The model was calibrated with a wear coefficient determined from an experimental wear test. Implicit FE analyses were then performed for variations in coefficient of friction, polyethylene elastic modulus, radial clearance, and polyethylene component thickness to investigate their effects on wear. Results. Using the initial loading protocol (single-peaked axial load profile of 300-1750 N) from the experimental wear test, the polyethylene wear rate was 9.82 mg per million cycles. When a double-peaked loading profile (600-2000 N) was applied, the wear rate increased to 11.77 mg per million cycles. Parametric design variations produced only small changes in wear rates for this simulation. Conclusions. The chosen design variables had little effect on the resultant wear rates. The comparable wear rate for the THR validation analysis was 16.17 mg per million cycles, indicating that, using this framework, the wear potential of the TDR was equivalent to, if not better, than the THR using joint-specific loading standards.
引用
收藏
页码:165 / 173
页数:9
相关论文
共 50 条
  • [21] Finite element simulation of the wear of polyoxymethylene in pin-on-disc configuration
    Benabdallah, H.
    Olender, D.
    WEAR, 2006, 261 (11-12) : 1213 - 1224
  • [22] Wear Simulation Modeling by Using the Finite Element Method
    Pelagić, Zoran
    Nágeľ, Martin
    Žmindák, Milan
    Riecky, Daniel
    Manufacturing Technology, 2015, 15 (02): : 21 - 21
  • [23] Adaptive finite element simulation of wear evolution in radial sliding bearings
    Rezaei, Ali
    Van Paepegem, Wim
    De Baets, Patrick
    Ost, Wouter
    Degrieck, Joris
    WEAR, 2012, 296 (1-2) : 660 - 671
  • [24] Finite element simulation of high cycle fretting wear using an implicit adaptive cycle jump
    Caradec, Quentin
    Breuze, Matthieu
    Maitournam, Habibou
    Prabel, Benoit
    Fayard, Jean-Luc
    WEAR, 2023, 522
  • [25] ROBOTIC SIMULATION OF THE EFFECTS OF SURGICAL PLACEMENT OF THE PRODISC-L ON MOTION SEGMENT MECHANICS: AN IN VITRO HUMAN CADAVERIC LUMBAR MODEL
    Dhillon, Braham K.
    Wido, Daniel M.
    DiAngelo, Denis J.
    Bertagnoli, Rudolph
    Kelly, Brian P.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, 2010, 2010, : 491 - 492
  • [26] Effect of Increasing Implant Height on Lumbar Spine Kinematics and Foraminal Size Using the ProDisc-L Prosthesis
    Gaffey, John L.
    Ghanayem, Alexander J.
    Voronov, Michael L.
    Havey, Robert M.
    Carandang, Gerard
    Abjornson, Celeste
    Patwardhan, Avinash G.
    SPINE, 2010, 35 (19) : 1777 - 1782
  • [27] A Two Dimensional Simulation of Crack Propagation using Adaptive Finite Element Analysis
    Alshoaibi, Abdulnaser M.
    JOURNAL OF COMPUTATIONAL APPLIED MECHANICS, 2018, 49 (02): : 335 - 341
  • [28] Biomechanical Analysis of the Cervical Spine Following Disc Degeneration, Disc Fusion, and Disc Replacement: A Finite Element Study
    Gandhi, Anup A.
    Grosland, Nicole M.
    Kallemeyn, Nicole A.
    Kode, Swathi
    Fredericks, Douglas C.
    Smucker, Joseph D.
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2019, 13 (06): : 491 - 500
  • [29] Simulation of a knee replacement during a gait cycle using explicit finite element analysis
    Taylor, M
    JOURNAL OF BIOMECHANICS, 2005, 38 (03) : 637 - 637
  • [30] Simulation of wear and contact pressure distribution at the pad-to-rotor interface in a disc brake using general purpose finite element analysis software
    Soderberg, Anders
    Andersson, Soren
    WEAR, 2009, 267 (12) : 2243 - 2251