Comparison of diagnostic ability of standard automated perimetry, short wavelength automated perimetry, retinal nerve fiber layer thickness analysis and ganglion cell layer thickness analysis in early detection of glaucoma

被引:7
|
作者
Kalyani, V. K. S. [1 ]
Bharucha, Khurshed M. [1 ]
Goyal, Nikhil [2 ]
Deshpande, Madan M. [1 ]
机构
[1] PBMAs HV Desai Eye Hosp, Pune, Maharashtra, India
[2] RNT Med Coll, Udaipur, Rajasthan, India
关键词
Diagnostic ability; ganglion cell layer; glaucoma; retinal nerve fiber layer; short-wavelength automated perimetry; spectral-domain optical coherence tomography; standard automated perimetry; OPTICAL COHERENCE TOMOGRAPHY; COMPLEX;
D O I
10.4103/ijo.IJO_2409_20
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to compare the diagnostic ability of macular ganglion cell layer (GCL) analysis using spectral domain optical coherence tomography against retinal nerve fiber layer analysis (RNFL), short-wavelength automated perimetry (SWAP), and standard automated perimetry (SAP) in early detection of glaucoma. Methods: Participants fulfilling the inclusion criteria were consecutively enrolled from the glaucoma clinic of tertiary care eye hospital in Western India from November 2015 to October 2016. The subjects underwent a detailed evaluation by trained glaucoma specialists. On suspicion of glaucoma, the patients underwent SAP, SWAP, and SD-OCT for GCL and RNFL analysis. Results: There were 91 patients in total of which experts classified 54 eyes into GON and 37 eyes into nonglaucomatous group. Sensitivity of SAP (42.59%) was significantly lower (P < 0.05) than that of average GCL thickness (79.63%) and average RNFL thickness (72.22%). Specificity and positive LR of SWAP (97.3% and 19.19, respectively) and SAP (94.6% and 7.88, respectively) were greater than those of GCL (81.08% and 4.21) and RNFL (67.57% and 2.23) parameters. Negative LR of average GCL thickness (0.25) was superior to that of average RNFL thickness (0.411), SWAP (0.495), and SAP (0.607). Conclusion: Macular GCL parameters perform better than RNFL parameters in patients with early glaucomatous damage. There is superior ability of SWAP over SAP in detecting glaucomatous changes in glaucoma suspect group. GCL thickness analysis has higher sensitivity and negative likelihood ratio, whereas SWAP had higher specificity and positive likelihood ratio. Thus, combining both tests can lead to better diagnostic ability for early glaucomatous damage.
引用
收藏
页码:1108 / 1112
页数:5
相关论文
共 50 条
  • [41] A comparison of short wavelength automated perimetry with frequency doubling perimetry for the early detection of visual field loss in ocular hypertension
    Landers, J
    Goldberg, I
    Graham, S
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 28 (04): : 248 - 252
  • [42] Automated Detection of Retinal Nerve Fiber Layer by Texture-Based Analysis for Glaucoma Evaluation
    Septiarini, Anindita
    Harjoko, Agus
    Pulungan, Reza
    Ekantini, Retno
    HEALTHCARE INFORMATICS RESEARCH, 2018, 24 (04) : 335 - 345
  • [43] Glaucoma Diagnostic Ability of the New Circumpapillary Retinal Nerve Fiber Layer Thickness Analysis Based on Bruch's Membrane Opening
    Lee, Eun Ji
    Lee, Kyoung Min
    Kim, Hyunjoong
    Kim, Tae-Woo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (10) : 4194 - 4204
  • [44] Diagnostic performance of ganglion cell and retinal nerve fiber layer thickness in alcoholic optic neuropathy
    Michau, Stephanie
    Perney, Pascal
    Donnadieu-Rigolle, Helene
    Villain, Max
    Daien, Vincent
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [45] Compensation of anatomical confounders improves the diagnostic ability of retinal nerve fiber layer thickness to detect glaucoma
    Schmetterer, Leopold
    Schwarzhans, Florian
    Wong, Damon
    Cheng, Ching-Yu
    Aung, Tin
    Fischer, Georg
    Vass, Clemens
    Chua, Jacqueline
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [46] The Pattern of Retinal Nerve Fiber Layer and Macular Ganglion Cell-Inner Plexiform Layer Thickness Changes in Glaucoma
    Choi, Jin A.
    Shin, Hye-Young
    Park, Hae-Young Lopilly
    Park, Chan Kee
    JOURNAL OF OPHTHALMOLOGY, 2017, 2017
  • [47] Comparison of visual field using standard automated and kinetic perimetry in patients with chiasmal compression. Correlation with peripapillary retinal nerve fiber layer
    Monteiro, Mario L. R.
    Nascimento Rocha, Arthur Andrade
    Marchesi Mello, Luiz Guilherme
    Benassi, Thais De Souza
    Cunha, Leonardo Provetti
    Zacharias, Leandro Cabral
    Preti, Rony Carlos
    Hokazono, Kenzo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [48] Diagnostic Ability of Retinal Nerve Fiber Layer Thickness Deviation Map for Localized and Diffuse Retinal Nerve Fiber Layer Defects
    Shin, Joong Won
    Seong, Mincheol
    Lee, Jung Wook
    Hong, Eun Hee
    Uhm, Ki Bang
    JOURNAL OF OPHTHALMOLOGY, 2017, 2017
  • [49] Retinal Nerve Fiber Layer and Ganglion Cell Complex Thickness in Adult Children of Patients With Pseudoexfoliation Glaucoma
    Gun, Raziye Donmez
    Gunaydin, Nesrin Tutas
    Penbe, Aysegul
    Kivrak, Ulviye
    Simsek, Saban
    JOURNAL OF GLAUCOMA, 2023, 32 (02) : 101 - 106
  • [50] Correlation of Frequency-doubling Perimetry With Retinal Nerve Fiber Layer Thickness and Optic Disc Size in Ocular Hypertensives and Glaucoma Suspects
    Kaushik, Sushmita
    Pandav, Surinder Singh
    Ichhpujani, Parul
    Gupta, Amod
    JOURNAL OF GLAUCOMA, 2011, 20 (06) : 366 - 370