Comparison of diagnostic ability of standard automated perimetry, short wavelength automated perimetry, retinal nerve fiber layer thickness analysis and ganglion cell layer thickness analysis in early detection of glaucoma

被引:7
|
作者
Kalyani, V. K. S. [1 ]
Bharucha, Khurshed M. [1 ]
Goyal, Nikhil [2 ]
Deshpande, Madan M. [1 ]
机构
[1] PBMAs HV Desai Eye Hosp, Pune, Maharashtra, India
[2] RNT Med Coll, Udaipur, Rajasthan, India
关键词
Diagnostic ability; ganglion cell layer; glaucoma; retinal nerve fiber layer; short-wavelength automated perimetry; spectral-domain optical coherence tomography; standard automated perimetry; OPTICAL COHERENCE TOMOGRAPHY; COMPLEX;
D O I
10.4103/ijo.IJO_2409_20
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to compare the diagnostic ability of macular ganglion cell layer (GCL) analysis using spectral domain optical coherence tomography against retinal nerve fiber layer analysis (RNFL), short-wavelength automated perimetry (SWAP), and standard automated perimetry (SAP) in early detection of glaucoma. Methods: Participants fulfilling the inclusion criteria were consecutively enrolled from the glaucoma clinic of tertiary care eye hospital in Western India from November 2015 to October 2016. The subjects underwent a detailed evaluation by trained glaucoma specialists. On suspicion of glaucoma, the patients underwent SAP, SWAP, and SD-OCT for GCL and RNFL analysis. Results: There were 91 patients in total of which experts classified 54 eyes into GON and 37 eyes into nonglaucomatous group. Sensitivity of SAP (42.59%) was significantly lower (P < 0.05) than that of average GCL thickness (79.63%) and average RNFL thickness (72.22%). Specificity and positive LR of SWAP (97.3% and 19.19, respectively) and SAP (94.6% and 7.88, respectively) were greater than those of GCL (81.08% and 4.21) and RNFL (67.57% and 2.23) parameters. Negative LR of average GCL thickness (0.25) was superior to that of average RNFL thickness (0.411), SWAP (0.495), and SAP (0.607). Conclusion: Macular GCL parameters perform better than RNFL parameters in patients with early glaucomatous damage. There is superior ability of SWAP over SAP in detecting glaucomatous changes in glaucoma suspect group. GCL thickness analysis has higher sensitivity and negative likelihood ratio, whereas SWAP had higher specificity and positive likelihood ratio. Thus, combining both tests can lead to better diagnostic ability for early glaucomatous damage.
引用
收藏
页码:1108 / 1112
页数:5
相关论文
共 50 条
  • [31] Relationship Between Standard Automated Perimetry and Retinal Nerve Fiber Layer Parameters Obtained With Optical Coherence Tomography
    Lopez-Pena, Maria J.
    Ferreras, Antonio
    Larrosa, Jose M.
    Polo, Vicente
    Pablo, Luis E.
    JOURNAL OF GLAUCOMA, 2011, 20 (07) : 422 - 432
  • [32] Retinal Nerve Fiber Layer Progression in Glaucoma A Comparison between Retinal Nerve Fiber Layer Thickness and Retardance
    Xu, Guihua
    Weinreb, Robert N.
    Leung, Christopher K. S.
    OPHTHALMOLOGY, 2013, 120 (12) : 2493 - 2500
  • [33] Retinal nerve fiber layer measurement by optical coherence tomography in glaucoma suspects with short-wavelength perimetry abnormalities
    Mok, KH
    Lee, VWH
    So, KF
    JOURNAL OF GLAUCOMA, 2003, 12 (01) : 45 - 49
  • [34] Comparison of retinal nerve fiber layer (RNFL) optical texture analysis (ROTA) versus RNFL thickness analysis for measurement of retinal nerve fiber layer defects in early glaucoma
    Ho, Jane
    Guo, Yawen
    Lo, Carmen Sze Ching
    Lai, Gilda
    Lam, Alexander
    Leung, Christopher Kai-Shun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [35] Glaucoma Diagnostic Accuracy of Ganglion Cell-Inner Plexiform Layer Thickness: Comparison with Nerve Fiber Layer and Optic Nerve Head
    Mwanza, Jean-Claude
    Durbin, Mary K.
    Budenz, Donald L.
    Sayyad, Fouad E.
    Chang, Robert T.
    Neelakantan, Arvind
    Godfrey, David G.
    Carter, Randy
    Crandall, Alan S.
    OPHTHALMOLOGY, 2012, 119 (06) : 1151 - 1158
  • [36] Evaluation of ganglion cell-inner plexiform layer thickness in the diagnosis of preperimetric glaucoma and comparison to retinal nerve fiber layer
    Deshpande, Gunjan A.
    Gupta, Richa
    Bawankule, Prashant
    Raje, Dhananjay
    Chakraborty, Moumita
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (05) : 1113 - 1119
  • [37] The relationship between Rarebit perimetry and OCT-derived retinal nerve fibre layer thickness in glaucoma
    Katsanos, Andreas
    Labiris, Georgios
    Fanariotis, Michael
    Tsirouki, Theodora
    Chatzoulis, Dimitrios
    ACTA OPHTHALMOLOGICA, 2008, 86 (08) : 871 - 876
  • [38] NEW METHODS OF ANALYSIS FOR SHORT-WAVELENGTH AUTOMATED PERIMETRY (SWAP) FOR DETECTION OF GLAUCOMA AND ITS PROGRESSION
    SAMPLE, PA
    MARTINEZ, GA
    ZANGWILL, LM
    WEINREB, RN
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S390 - S390
  • [39] Detection of early visual field loss in glaucoma using frequency-doubling perimetry and short-wavelength automated perimetry
    Landers, JA
    Goldberg, I
    Graham, SL
    ARCHIVES OF OPHTHALMOLOGY, 2003, 121 (12) : 1705 - 1710
  • [40] SHORT-WAVELENGTH AUTOMATED PERIMETRY FOR ANALYSIS OF SECONDARY AND NORMAL-TENSION GLAUCOMA
    SAMPLE, PA
    JUANG, PSC
    WEINREB, RN
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 2189 - 2189