Development of an MR-Compatible High-Definition Flexible Endoscope for Real-Time MR Image-Guided Microwave Ablation

被引:0
|
作者
Yamada, Atsushi [1 ]
Naka, Shigeyuki [2 ,3 ]
Khiem Tran Dang [1 ]
Morikawa, Shigehiro [4 ]
Tani, Tohru [1 ]
机构
[1] Shiga Univ Med Sci, Dept Res & Dev Innovat Med Devices & Syst, Otsu, Shiga 5202192, Japan
[2] Shiga Univ Med Sci, Dept Surg, Otsu, Shiga, Japan
[3] Hino Mem Hosp, Dept Surg, Hino, Tokyo 5291642, Japan
[4] Shiga Univ Med Sci, Mol Neurosci Res Ctr, Otsu, Shiga, Japan
关键词
Magnetic resonance compatibility; Flexible endoscope; Navigation system; COAGULATION THERAPY; THERMOCOAGULATION;
D O I
10.1007/978-981-13-5859-3_4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study aims to develop a magnetic resonance (MR)-compatible flexible endoscope for minimally invasive real-time MR image-guided microwave ablation as proposed by the author with a widely available 3-Tesla close-bore MR scanner and to assess the feasibility of including a position tracking sensor. A unique MR-compatible high-definition (HD) endoscope was developed to access a target organ from outside the scanner bore by obtaining endoscope optical camera and scan images simultaneously. The camera unit consists of a CMOS image sensor with 400 x 400 pixels. The camera head and the lens barrel are made of phosphor bronze and a Pebax elastomer sheath with a 2.1 mm diameter shielded by tin-plated copper wires. The image resolution was up-converted to 700 x 700 pixels using a high-resolution image processing technique. The endoscope had two working channels (2.0 mm in each outer diameter) and two sensor ports (2.5 mm in each outer diameter). One port had a gradient-magnetic-based tracking sensor to identify the tip position and orientation; the outer diameter and length of the endoscope were 11 and 1200 mm. A pig was scanned as a pre-procedural MR image and the result was used as navigation images to assess the endoscope's feasibility. The camera image quality was sufficient to identify organs without critical noise during scanning, and its resolution was 295 times that of the conventional MR-compatible fiber endoscope we developed. The refresh rates of the sensor position and orientation were <0.5 s, which includes data transmission from the scanner to the navigation software. The verification study showed that the proposed MR-compatible endoscope has the potential to enable a surgeon to access target organs from the outside bore while simultaneously obtaining optical and scanned images.
引用
收藏
页码:21 / 26
页数:6
相关论文
共 50 条
  • [31] Real-time 3D high-definition image: Transmission experiment for cardiac surgery by NICT and URCF
    Kimura, Kazuhiro
    Takahashi, Takashi
    Ohkawa, Mitsugu
    Akaishi, Akira
    Asai, Toshio
    Akioka, Maki
    Suzuki, Ryutaro
    Nakamura, Yasunori
    Terada, Shigeru
    Kouno, Michiyuki
    Journal of the National Institute of Information and Communications Technology, 2010, 57 (1-2): : 221 - 237
  • [32] Initial Clinical Application of Real-time MR Imaging-guided Ablation of Cardiac Arrhythmia in Patients with Atrial Flutter
    Nordbeck, Peter
    Quick, Harald H.
    Bauer, Wolfgang R.
    Ertl, Georg
    Ladd, Mark E.
    Ritter, Oliver
    RADIOLOGY, 2014, 273 (01) : 310 - 311
  • [33] Robotic-Assisted Real-Time Image-Guided: From System Development to Ex Vivo Experiment
    Farouk, Z. I. Bibi
    Jiang, Shan
    Yang, Zhiyong
    Umar, Abubakar
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2023, 48 (03) : 3709 - 3722
  • [34] Overview of Our Less Invasive Operation System-Development of Three Dimensional Real-Time MR Image Guided Operation System Using Microwave Devices and Relating Technologies
    Tani, Tohru
    Naka, Shigeyuki
    Yamada, Atsushi
    Tani, Soichiro
    Dang Tran Khiem
    Nguyen Quoc Vinh
    7TH INTERNATIONAL CONFERENCE ON THE DEVELOPMENT OF BIOMEDICAL ENGINEERING IN VIETNAM (BME7): TRANSLATIONAL HEALTH SCIENCE AND TECHNOLOGY FOR DEVELOPING COUNTRIES, 2020, 69 : 11 - 13
  • [35] Robotic-Assisted Real-Time Image-Guided: From System Development to Ex Vivo Experiment
    Z. I. Bibi Farouk
    Shan Jiang
    Zhiyong Yang
    Abubakar Umar
    Arabian Journal for Science and Engineering, 2023, 48 : 3709 - 3722
  • [36] Initial Clinical Application of Real-time MR Imaging-guided Ablation of Cardiac Arrhythmia in Patients with Atrial Flutter Response
    Grothoff, Matthias
    Piorkowski, Christopher
    Hindricks, Gerhard
    Gutberlet, Matthias
    RADIOLOGY, 2014, 273 (01) : 311 - 311
  • [37] Real-time volumetric relative dosimetry for magnetic resonance-image-guided radiation therapy (MR-IGRT)
    Lee, Hannah J.
    Kadbi, Mo
    Bosco, Gary
    Ibbott, Geoffrey S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (04):
  • [38] A flexible view ordering technique for high-quality real-time 2DFT MR fluoroscopy
    Busse, RF
    Kruger, DG
    Debbins, JP
    Fain, SB
    Riederer, SJ
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (01) : 69 - 81
  • [39] Towards Real-Time High-Definition Image Snow Removal: Efficient Pyramid Network with Asymmetrical Encoder-Decoder Architecture
    Ye, Tian
    Chen, Sixiang
    Liu, Yun
    Ye, Yi
    Bai, JinBin
    Chen, Erkang
    COMPUTER VISION - ACCV 2022, PT III, 2023, 13843 : 37 - 51
  • [40] Real-Time Monitoring of Tissue Displacement and Temperature Changes during MR-Guided High Intensity Focused Ultrasound
    Bour, Pierre
    Marquet, Fabrice
    Ozenne, Valery
    Toupin, Solenn
    Dumont, Erik
    Aubry, Jean-Francois
    Lepetit-Coiffe, Matthieu
    Quesson, Bruno
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (05) : 1911 - 1921